AUTOUTLET P6100 100MHz Oscilloscope Probe Kit User Guide

June 1, 2024
AUTOUTLET

AUTOUTLET P6100 100MHz Oscilloscope Probe Kit

Specifications

  • Model: P6000 Oscilloscope Probe
  • Bandwidth: P6100 – 100MHz, P6150 – 150MHz, P6200 – 200MHz, P6250 – 250MHz, P6300 – 300MHz
  • Rise Time : P6100 – 3.5ns, P6150 – 2.3ns, P6200 – 1.75ns, P6250 – 1.4ns, P6300 – 1.15ns
  • Attenuation Ratio: 1X and 10X
  • Input Resistance: Varies based on model
  • Input Capacitance: 1X mode: 70pF~120pF, 10X mode: 13pF~17pF
  • Max. Input Voltage: 1X: 200V, 10X: 600V

Product Usage Instructions

Frequency Compensation
Before taking any measurements using the probe:

  1. Check the compensation of the probe.
  2. Adjust it to match the channel inputs.

To compensate the probe

  1. Connect the probe to the signal source on your oscilloscope.
  2. Set the probe to 10X position.
  3. Adjust the compensation trimmer until seeing a flat-top squarewave on the display.

Probe Connection

When connecting the probe:

  1. Use the alligator clip to attach the probe to a ground reference.
  2. Connect the BNC connector to the oscilloscope measuring channel.

Grounding:
Ensure proper grounding for better signal integrity:

  • Utilize the ground spring for a shorter grounding path.

Stability and Reliability
Use the locating sleeve to ensure the stability and reliability of the tip exposed to the test point.

INSTRUCTION

Frequency Compensation
Before taking any measurements using a probe, first check the compensation of the probe and adjust it to match the channel inputs. Most oscilloscopes have a square wave reference signal available at a terminal on the front panel used to compensate the probe. Connect the probe to the signal source on your oscilloscope. Set the probe to 10X position. Adjust the trimmer until seeing a flat-top square wave on the display

Voltage vs Frequency Rating Curve(RMS)

WARNING:

  • Review this user manual carefully to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
  • The measurement category of a combination of a PROBE ASSEMBLY and an accessory is the lower of the measurement categories of the PROBE ASSEMBLY and the accessory.
  • If the PROBE ASSEMBLY is used in a manner not specified by the manufacturer, the protection provided by the PROBE ASSEMBLY may be impaired.

Accessories and Features

  • P6000 is provided with several accessories designed to make probing and measurement simpler. Please take a moment to familiarize yourself with these accessories and their uses.

OVERVIEW

AUTOUTLET-P6100-100MHz-Oscilloscope-Probe-Kit-FIG-3

Probe Characteristics

Accessory Kit

Email: eformationuk@outlook.com

FAQ

  • Q: What is the purpose of the compensation trimmer on the probe?
    • A: The compensation trimmer is used for frequency compensation adjustment in 100X mode to match the channel inputs.
  • Q: How can I ensure proper grounding when using the probe?
    • A: Use the ground lead with the alligator clip and ground spring provided to establish a good grounding connection for better signal integrity.