vetus ILT120PL Inspection Lids for Rigid Water Tanks Instruction Manual

June 9, 2024
vetus

vetus ILT120PL Inspection Lids for Rigid Water Tanks

vetus-ILT120PL-Inspection-Lids-for-Rigid-Water-Tanks-PRODACT-
IMG

Introduction

This manual is intended for the ILT120PL and ILT- 120PH inspection lids for riged (waste) water tanks. The tank may be made of plastic, polyester or metal. The ILT120PL is suitable for tanks with a wall thickness of 0.8 to 4 mm, the ILT120PH for tanks with a wall thickness of 4 to 10 mm, for example the VETUS ATANK.

Note Refer to the tank’s installation manual. Ensure proper venting so that the tank is pressure-free at all times.

Installation

Cutting the hole for the inspection lid

  • Position the inspection lid on the top face of the tank. If a VETUS tank is used, then it should be fitted with plug P on the top and the inspection lid should preferably be located so that plug P is removed when the hole is cut.
  • Cut the hole in the tank and remove all burrs. Preferably use a holesaw (159 mm, 6 1/4” diam.), VETUS code: VSAW159.
  • Clean the inside of the tanks before fitting the inspection lid.

Checking the rubber seal

  • Check that the rubber seal is correctly positioned between the two flanges. The bolts must be tightened evenly without compressing the rubber seal.

Installation of connector lid

  • Place the complete flange (1) in the hole of the tank. The screw holes are numbered. For tightening, use the order (1) – (2) – (3) – (4) – (5) .
  • Tighten each of the 5 screws (2) one (-1-) revolution (clockwise) and check if the flange can be rotated easily by hand. Repeat this until the flange can no longer be rotated easily.
  • Now all screws must be tightened five (-5) turns. Do this by, in turn, first tightening each screw three (-3-) and then each screw two (-2-) turns.

Lid

  • Screw the lid onto the flange. If necessary, use a wrench (5), VETUS code: WRILT, to tighten the lid.

Note! Check the tightness of all connections before filling the tank.

vetus-ILT120PL-Inspection-Lids-for-Rigid-Water-Tanks-
FIG-1vetus-ILT120PL-Inspection-
Lids-for-Rigid-Water-Tanks-FIG-2 vetus-ILT120PL-Inspection-Lids-for-Rigid-Water-Tanks-
FIG-3

Service parts

description

  1. Rubber seal for ILT120PL, height 16 mm, for wall thickness 0.8 up to 4 mm
  2. Rubber seal for ILT120PH, height 22 mm, for wall thickness 4 up to 10 mm
  3. Cover incl. gasket for inspection lid
  4. Gasket

The blind plate (A) of the inspection cover can be replaced by one of the different connection kits. These connection kits have the necessary connections for respectively a tank for water (ILTCOND) or waste water (ILTCONW).

Fokkerstraat 571 – 3125 BD Schiedam – Holland Tel.: +31 (0)88 4884700 – sales@vetus.nlwww.vetus.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals