BEGA 84964 RGBW Compact Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
BEGA 84964 RGBW Compact Floodlight
Compact floodlight RGBW
Dimensions
Instructions for use
Application
Compact floodlight with mounting box for permanent installations on a wall,
under a ceiling or on a pillar.
The floodlight can be controlled by DALI colour light control.
Product description
Luminaire made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Clear safety glass
Reflector surface made of pure aluminium
Rotation range of floodlight 350°
Swivel range -15°/+90°
Mounting box with 2 fixing holes
ø 4.8mm · 67mm spacing
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm, max. 5G1.5
Connecting terminal 2.5
with plug connection
Earth conductor connection
BEGA Ultimate Driver®
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains
and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect
temperature-sensitive components without
switching off the luminaire
Safety class I
Protection class IP65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Wind catching area: 0.031 m²
Weight: 2.7 kg
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage 34.8 W
Luminaire connected wattage 38.6 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
Module designation LED-1160/RGBW
Colour temperature of the white LED 4000K
Luminaire luminous flux 2518 lm
Luminaire luminous efficiency 65,2 lm/W
Lighting technology
Wide beam light distribution Half beam angle 24° For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo hexagon socket head screws (wrench size 3 mm) at the mounting box and remove mounting plate. Pass the power connecting cable through the cable entry in the mounting plate. Note position of application of the mounting plate “arrow down”. Fix the mounting plate with enclosed or any other suitable fixing material onto the mounting surface. Be sure to use the gasket rings supplied. Make earth conductor connection. Push silicone sleeves over the lines and make electrical connection to terminal (plug connection). For digital control please use the 2-pole plug connector DA, DA. In case this connector is not used the luminaire will be operated at full light output. Push plug into coupler as far as it will go. Make sure that gasket is positioned correctly.
Place floodlight unit onto the mounting plate as displayed in the sketch, align and screw together firmly.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 7Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The replacement can be carried out by a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2mm) in the trim ring.
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise. Replace LED module. Please follow the installation
instructions for the LED module. Inspect and, if necessary, replace the
luminaire gaskets. Defective glass must be replaced. Place the trim ring with
glass and reflector on the floodlight housing so that the notches in the trim
ring and luminaire housing sit on top of each other. Twist on the trim ring
clockwise as far as the stop. Screw in the locking pin.
Accessories
71 291 Optical filter flat beam
71281 Shield
71 286 Cylindrical shield
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass
Trim ring silver with glass
LED power supply unit
LED module
Reflector
Gasket housing
Gasket trim ring
Gasket mounting box
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>