FIELD CONTROLS Trio Pro Floor Type Air Purifier User Manual
- June 6, 2024
- FIELD CONTROLS
Table of Contents
READ AND SAVE THESE INSTRUCTIONS
Trio Pro
FLOOR-TYPE AIR PURIFIER
USER MANUAL
SAFETY PRECAUTIONS
Please read the instructions carefully and completely before proceeding with the installation of the product to better understand the product and to prevent personal injury and damage.
WARNING – Failure to follow the instructions below can damage the product or cause personal injury.
- To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
- Do not spray paint, insecticide, ethyl alcohol, or any other chemical agent on the device’s surface. It can cause a crack, electric shock, or fire. If a chemical accumulates inside the device, it will be discharged from the air outlet and dispersed back into the living space. Please ensure the room is well ventilated if using any of the listed chemicals.
- The air purifier should not be used in a flammable and combustible environment or environment with corrosive air.
- When the device is on, please do not touch the air inlet or outlet, or put a hand or any object into the air outlet to prevent injury or damage to the product.
- Do not sit on or place any objects on the device.
- The appliance is designed for indoor, dry location installation. Not intended for bathroom or high humidity environments. Improper usage may cause fire, electric shock, or malfunction.
- Do not modify, dismantle or repair the device. This may cause fire, electrical shock, or malfunction.
WARNING – Failure to follow the instructions below can damage the product or cause personal injury.
-
Do not use the appliance if the power cord or plug is broken, damaged and/or defective.
-
This can cause electric shock or fire. Do not touch the power cord with a wet hand.
The power cord should only be replaced by the manufacturer, its authorized professional. -
On a recurring basis, or as needed, please clean the filter cover and the pre-filter mesh to ensure the air purifier delivers its highest performance.
-
Unplug the device from the wall before moving or performing any maintenance.
-
Unplug the device from the wall if it will not be used for a long period of time.
-
Turn the device off and unplug from the wall if there is a peculiar smell coming from the appliance. Contact manufacturer technical support if this occurs.
-
Do not place foreign objects into the air outlet. Please check the unit for foreign objects before use.
-
The air purifier should be placed at least 20in (50cm) from the wall or other objects.
-
Unplug or disconnect the appliance from the power supply before performing any service or maintenance on the appliance.
PRODUCT OVERVIEW
Terminology
- Control Panel
- Display Panel
- Sensor
- Power Inlet
- Filter Cover
- Pre-Filter
- HEPA with Activated Carbon Filter
- PRO-Cell Catalyst
- Air Outlet
- Magnet
- UVC Germicidal Lamps
- Air Inlet
Specifications
PRODUCT MODEL | Trio Pro |
---|---|
Rated Voltage (V) | 120 |
Rated Power (W) | 130 |
Frequency (Hz) | 60 |
CADR Rating (CFM) | 530 |
Sound (dBA) | 60 |
Weight (lbs.) | 39.6 |
Dimensions W x H x D (inches) | 18.6 x 15.2 31” |
Product Features and Functions
The Trio Pro air purifier combines three state-of-the-art air treatment
processes into one powerful system. The 3-stage system boasts a True HEPA
filtration for maximum particulate capture down to .03 microns, four high-
intensity UVC germicidal lamps for maximum viral and bacterial abatement, and
PRO-Cell™ Catalyst toxic gas reduction
technology to significantly reduce odors and volatile organic compounds
(VOCs). The True HEPA filter uses the principle of laminar flow filtration to
filter out common particles, removing at least 99.97% of dust, pollen, mold,
bacteria, and any airborne particles as small as 0.3 microns.
The carbon filter uses high-efficiency activated carbon to effectively remove
odor gas benzene, ammonia, and other harmful gases in the air.
The four UVC lamps excite the PRO-Cell Catalyst, dramatically reducing toxic
VOCs, odors, and biochemicals in the air (at a rate greater than or equal to
90%) to less than 3 hours.
Operating Instructions
Control Panel View
Operating Instructions
-
Power On/Off
Press to turn the appliance on or off. -
Speed
The Speed 1 and “ ” are fully bright by default after turning on the appliance. Click on “ ” to accelerate the fan speed, while “ ” is to decelerate. Press the button one time to accelerate or decelerate one gear. -
Slide Controls
Control the wind speed according to the speed finger slides. Slide right to increase wind speed, instead, slide left to decrease wind speed. Fan speed increases by two fan lights, there are four fan speeds total. -
Turbo Mode
Press “ ” or “ ” until max speed to reach Turbo mode. The “ ” and all speed indicators will be fully illuminated. -
AUTO mode
Auto
Press “Auto” to enter AUTO mode. Auto mode will adjust the fan speed automatically between 1 to 5 according to the air quality level. -
UVC
The UVC lamp is ON by default when the appliance is turned on. Press the UV button to turn on or off, indicated by the shield light indicator. If the light is on, the UVC lamp is on, if the light is off, the UVC lamp is off. When the UVC lamp needs to be replaced, the UVC indicator will blink notifying the user. After the UVC light is replaced, press, and hold the UVC light change indicator for 5 seconds to reset the UVC light indicator. -
Child Lock
After the purifier is turned on, press and hold the UVC button for 3 seconds to turn on the child lock. Press and hold the UVC shield icon for 3 seconds again to turn the child lock off. While the child lock is on, all buttons will be disabled except to turn off the child lock.
Operating Instructions -
Filter Reset
The Filter icon will blink when the filters require replacement. After replacing the filters press and hold the Auto mode button for 5 seconds to reset the filter indicator. -
Power off before removing the filter cover
Before replacing the filter, power off the appliance and remove the power cord from the outlet. After replacing the filter, plug the appliance into the outlet and power on.
Ensure the filter covers are fully installed and closed, otherwise the power indicator will flash slowly. -
Particle Sensor and Fan Speed
The PM2.5 sensor requires a 1-minute warmup before displaying the PM2.5 value in real-time. A 60-second countdown will be displayed until the PM2.5 readings are presented. The PM2.5 readings, corresponding IAQ colors, and AUTO mode fan speed are provided in the following table below.
Standard | PM2.5(ug/m³ | Air Purifier Level | Speed(Auto) | Color |
---|---|---|---|---|
000-050 | Healthy | 1 | Blue | |
PM2.5 | 051-100 | Good | 2 | Green |
101-150 | Fair | 3 | Yellow | |
151-200 | Unhealthy | 4 | Orange | |
>200 | Poor | Turbo | Red |
Operating Instructions
12. Volatile Organic Compounds (VOC) and Fan Speed
The VOC sensor requires a 3-minute warmup, which will be displayed as a 180
second countdown. After the countdown, the VOC value will present VOC reading
in real-time.
The air quality color level will be directly displayed as shown in the table
below and associated fan speed in AUTO mode.
Standard | VOC Level (mg/m³) | Air Purifier Level | Speed(Auto) | Color |
---|---|---|---|---|
VOC | 0.00-0.30 | Healthy | 1 | Blue |
0.31-0.60 | Good | 2 | Green | |
0.61-0.90 | Fair | 3 | Yellow | |
0.91-1.20 | Unhealthy | 4 | Orange | |
>1.20 | Poor | Turbo | Red |
Remote Control View
WARNING – Chemical Burn Hazard. Keep batteries away from children.
This product contains a lithium button/coin cell battery. If a new or used
lithium button/coin cell battery is swallowed or enters the body, it can cause
severe internal burns
and can lead to death in as little as 2 hours. Always completely secure the
battery compartment. If the battery compartment does not close securely, stop
using the product, remove the batteries, and keep them away from children. If
you think batteries might have been swallowed or placed inside any part of the
body, seek immediate medical attention. The battery cell shall be disposed of
properly, including keeping them away from children; as even used cells may
cause injury.
Operating Instructions Remote Control View
Operating Instructions
There are 9 buttons on the Remote Control: PowerON/OFF, AUTO mode, Speed, UV,
Light, (Child) Lock, Timer, Turbo, Sleep. The Speed button will cycle between
the 4 speeds: Speed 1 Speed 2 Speed 3 Speed 4 Speed 1, etc.
13.Sleep (Only for Remote Control)
When the Sleep button on the Remote Control is pressed, the display panel will
show “SLP” indicating the unit is entering Sleep mode. 5 seconds later, all
indicator lights will turn off and the display panel brightness will reduce by
20%. To exit Sleep mode, press the Sleep button, or any other buttons, and the
appliance will return to the previous state.
14.Timer (Only for Remote Control)
Press the timer button of the remote control to set when the appliance will
shut down. The display indicates the time, which can be set from 1 to 24 hrs
in increments
of 1 hour. Pressing the button will extend the timer by 1 hour each time. If
the timer function needs to be canceled, press and hold the timer button for 3
seconds to
cancel the timer setting.
15. Light (Only for Remote Control)
Press the Light button to turn off all lights on the appliance except the
power cord. All other functions will remain in their current state, just the
lights will turn off.
To exit this mode, press the Light mode button or any other button.
Getting Started
Installing Filter
There are filter covers on all filters of the appliance.
Before using the appliance, remove all packaging materials covering all the
filters and place the filters into the appliance as described below.
Note
Please ensure that the correct filter installation sequence is followed.
Otherwise, there may be damage to the product, and the filtration efficacy of
the unit may not be as effective as advertised.
Step 1 Grasp the handle on the panel with one hand and gently pull outward to remove it.
Step 2 Press down on the Pre-filter tabs (A) and pull outwards to remove (B). Gently remove the filter and PRO-Cell Catalyst from the appliance and remove the packaging.
Step 3 Gently place the PRO- Cell Catalyst (metal honeycomb) in the innermost position closest to the UVC lamp as shown in the figure with the tag pointing outwards. Step 4 Next, place the unpackaged HEPA with carbon filter back into the ppliance with the tag pointing outwards. Step 5 Place the Pre-filter frame into the slots on the bottom of the appliance and press the top towards the appliance until the clasps click. Step 6 Place the filter cover on the unit once all the filters have been installed. Repeat steps 1 – 6 on the opposite side.
MAINTENANCE INSTRUCTIONS
Please ensure the appliance is unplugged from the wall before performing any
maintenance.
To increase the life of the air purifier, perform regular maintenance and
care.
Before performing maintenance, be sure to shut down the air purifier and
unplug the power cord from the power source. After using the air purifier, if
the filter needs to be replaced, the Filter Replacement icon on the control
panel will flash, indicating the filter should be replaced. During the use of
the air
During the use of the air purifier, it is recommended that the pre-filter be
cleaned every three months to extend the filter service life and dust removal
effect. The filter set needs to be replaced after 6 months of use.
Note All maintenance parts can only be inspected and provided by our
authorized service agency.
Cleaning of the Appliance
When cleaning the air purifier, please turn off the power first and clean it
with a soft, dry cloth.
Do not use alcohol, gasoline, benzene, or other chemical solvents for
cleaning.
Suggestions: Clean the air purifier once a month. If the operating environment
is poor, increase the cleaning frequency.
The Pre-filter screen may be dusty. Remove the dust with a dust collector or a
vacuum to extend the usage period of the filter. (It is advised to clean the
filter once per month).
FILTER REPLACEMENT
- Replace with Field Controls Trio Pro Filter Kit # 602605600
- Turn off the appliance and remove the power cord from power supply before replacing filters.
The appliance will indicate when the filters require replacement, shown by the Filter Replacement light indicator on the control panel. However, the life of the filter may differ depending on the degree of pollution in the environment. The filter can be replaced earlier if necessary. To replace the filters, follow steps 1 through 6 on page 12 to page 13.
Filter | Clean/Replacement Period |
---|---|
Pre-Filter | Gently clean mesh screen with vacuum cleaner once per month |
HEPA with Activated Carbon | The filter should be replaced every 6 months |
In environments with poorer air quality, the filters may need to be replaced
more frequently.
The used filter shall be disposed of as non-combustible waste.
Note HEPA filters and activated carbon filters are best replaced every 3 to 6 months, depending on the use situation. High-efficiency HEPA filters, activated carbon filters, photocatalyst filters, and pre-filters cannot be washed.
REPLACEMENT OF UVC LAMP
WARNING – Skin or eye damage may result from direct exposure to the light
produced by the lamp in this appliance. Always shut down and disconnect the
power before replacing or servicing.
Replace lamps with Field Controls Trio ProUV lamp replacement kit Part Number
602605500.
Manufacturer: GMY Lighting Technology Co.,Ltd;model: UVCH8D15*288-G5
Replacement steps:
- Turn the appliance off and unplug from the power outlet.
- Remove all the filters after opening the front cover panel.
- Remove the UVC lamps by rotating them 90 degrees.
- Install new UVC lamps by inserting and rotating 90 degrees to lock in place.
- Return filters into the air purifier.
- Close front cover panel to complete installation
COMMON PROBLEMS AND SOLUTIONS
Problem | Possible Causes | Actions |
---|---|---|
The appliance does not turn on | If the power light is o ff, the unit is not | |
correctly plugged in. Please confirm the plug and socket connections. | Confirm |
the unit is plugged in. Try unplugging and plugging in the unit.
Productt works abnormally| There is a problem with the Product power
connection; works The filter cover is not abnormally placed properly.| Please
check whether the plug is inserted into the socket and check On/Off button
status; Re-install the filters.
Fresh air. outlet smoothly| The plastic package of the cannot be a new filter
is not removed; delivered The air outlet of purified is from the air blocked
by foreign matter| Remove any packaging from the filter.
Problem| Possible Causes| Actions
---|---|---
Poor odor removal| The ambient air quality of the room is very poor
The filter package needs to be replaced.The room
exceeds the effective are of this appliance| Open the window to improve air
ventilation;
Replace the activated carbon filter
The appliance generates blocked by foreign matter; abnormal sound while
running.| The air inlet or air outlet is blocked by foreign matter; A foreign
object has fallen into the air tube of the appliance| .
Unplug and remove the object blocking the airflow; Remove any foreign objects
in the appliance.
The unit is always detecting the high levels of particles| The sensor cover
is dusty; The unit operated in a dusty detecting environment.| The sensor
cover is dusty; Open the sensor panel and gently clean the detecting
environment. sensor with a clean cloth. Adjust the air purifier to operate at
higher speeds
When the UVC Lamp is turned on,
there is a dull sound and low airlfow| Is the filter packaging removed? Are
there foreign objects blocking the air inlet or air outlet| Remove the filter
package and reinstall according to instructions. Turn-off the appliance and
remove foreign objects
outlet smell| ● The filter has absorbed too much odor and
smoke;
● It is time to replace the filters.| The filter has absorbed
● It is time to replace the
● The odor gradually disappears after running the machine for a period of
time;
● Clean or replace the filter that nees to be replaced.
---|---|---
The remote control is faulty| ● The battery life is out of lifetime.
● The range is out of control.| ● Replace the batteries.
● Try to get close to the appliance.
The above table lists the common problems with this product.
Need Tech Support? Call us at
800-742-8368.
Office hours are 8am – 5pm EST.
TRANSPORTATION AND STORAGE CONDITIONS
It is recommended that the equipment be transported and stored under the
following conditions:
Ambient Temperature| Environmental
Humidity| Atmospheric
Pressure
---|---|---
40℃~+50℃
40F to 122F| ≤ 80 % RH| 70~106kPa
10 psi – 15 psi
Note This package includes an air-purifying appliance and an instruction
manual.
If parts are missing after unpacking, please contact the after-sales service
staff.
This manual may be downloaded and printed from the
Field Controls website
(www.fieldcontrols.com)
WARRANTY
For warranty information about this or any Field Controls product, visit:
www.fieldcontrols.com
Field Controls Technical Support
1.800.742.8368
Documents / Resources
|
FIELD CONTROLS Trio Pro Floor Type Air
Purifier
[pdf] User Manual
Trio Pro, Floor Type Air Purifier, Trio Pro Floor Type Air Purifier, Air
Purifier
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>