BEGA 50302K27 Ceiling and Wall Luminaire For Indoor Use Instruction Manual

June 1, 2024
BEGA

50 302
Ceiling and wall luminaire for indoor use

50302K27 Ceiling and Wall Luminaire For Indoor Use

BEGA 50302K27 Ceiling and Wall Luminaire For Indoor Use -
useInstructions for use

Application

Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.

Product description

Metal housing, finish colour white
Hand-blown opal glass, satin matt
2 mounting holes ø 6 mm
Distance apart 180 mm
2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5@
Connection terminal 2.5@
Earth conductor connection
LED power supply unit
220-240 V x 0/50-60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I
Impact strength IK03
Protection against mechanical
impacts < 0.35 joule
10 – Safety mark
– Conformity mark
Weight: 2.2 kg
This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

Module connected wattage 15.1 W
Luminaire connected wattage 17.6 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 45 °C

50 302 K27
Colour temperature 2700 K
Colour rendering index CRI > 90
Module luminous flux 2535 lm
Luminaire luminous flux  1839 lm
Luminaire luminous efficiency 104,5 lm / W

50 302 K3
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 2570 lm
Luminaire luminous flux 1865 lm
Luminaire luminous efficiency  106 lm/W

50 302 K4
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 2720 lm
Luminaire luminous flux  1974 lm
Luminaire luminous efficiency  112,2 lm / W

Notice prior to installation:

Luminaire with trim frame
The luminaire housing must be inserted in the trim frame (accessory) before it is mounted onto the mounting surface.
Make sure that the two openings in the trim frame coincide with the positions of the grub screws of the luminaire housing.

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Lead mains supply cable through the cable entry into the luminaire housing.
Fix the luminaire housing with enclosed or any other suitable fixing material onto the mounting surface.
It is imperative to use the enclosed gaskets.
Make earth and electrical connection to the terminal.BEGA 50302K27 Ceiling
and Wall Luminaire For Indoor Use - Installation

Position the glass over the luminaire housing so that the retaining springs fit into the two recesses in the raised edge of the glass.
Press the glass against the retaining springs at a flat angle as far as it will go and push it into the luminaire housing (see drawing).
Gentle pressure on the glass will fix it in the luminaire housing through the three lobes on the opposite side.BEGA 50302K27 Ceiling and Wall Luminaire
For Indoor Use - luminaire

IMPORTANT:
If the luminaire is to be installed on the ceiling, it is essential that the two grub screws (Allen screws) should be screwed with gentle pressure against the retaining springs.
In this way, the glass is held securely in place and is resistant to vibration.

Cleaning Maintenance

Clean luminaire regularly with solvent-free cleansers from dirt.

Opening the luminaire
Unscrew the two grub screws (Allen screws) of the luminaire housing as far as they will go.
A recess (identifiable by touch) in the edge of the glass indicates the direction from which the luminaire glass must be pressed against the spring pressure of the glass retaining springs in order to release it from the luminaire housing.
Pull the glass away from the luminaire housing against the holding force of the retaining springs and remove it.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted.
The LED unit can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Replace the LED unit.
Close the luminaire.
A damaged glass must be replaced.

Accessory Trim frames

For this luminaire metal trim frames in 3 enamel surfaces are optional available.
Trim frames are accessories and must be 0ordered separately.

| Part. No
---|---
Colour white| 13 137
Colour palladium| 13 138
Colour glossy silver| 13 139

Spares

Spare glass 11 003 279 .0R G
LED unit 2700 K 75 002 257 K27
LED unit 3000 K 75 002 257 K3
LED unit 4000 K 75 002 257 K4

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals