Milesight VS135 Ultra ToF People Counter User Guide
- June 2, 2024
- Milesight
Table of Contents
Milesight VS135 Ultra ToF People Counter
Specifications
- Model: 11:7379615
- Dimensions: 26 x 89 cm
- Weight: 4.58 kg
- Power: 736778849OKh
Product Usage Instructions
Assembly
- Lay out all the parts and ensure you have all the necessary tools.
- Follow the step-by-step instructions provided in the manual to assemble the product.
Operation
- Connect the power source according to the specified requirements.
- Turn on the product using the designated power button.
Maintenance
- Regularly clean the product with a damp cloth to remove dust and debris.
- Avoid exposing the product to extreme temperatures or direct sunlight.
Packing List
Hardware Introduction
PoE Version:
Non-PoE Version:
Button Descriptions
SIM Card Installation (Cellular Version Only)
Power Supply
Installation
Ceiling Mount
Installation condition: ceiling thickness > 30mm
Step 1: Take down the side covers
Step 2: Fix wall plugs into ceiling holes
Step 3: Remove rubber plugs on the rubber sleeve, connect all required wires
Note:
- Remove the rubber sleeve if waterproofing is not required for easy installation
- Use round wires
- Ensure the rubber sleeve and the bottom cover are tightly connected without a gap if waterproofing is required; if necessary, wrap the waterproof tapes around the wires to avoid any gap
- For non-PoE version devices, tighten the wires to avoid contact with internal modules
Step 4: Fix the device to the ceiling with mounting screws
Ceiling/Lintel Mount (with Optional VB01 Multifunctional Bracket)
Ceiling Mount
Lintel Mount
Installation Note
- Make sure the ToF sensor is facing down and the tilt angle from the ground is no greater than 15° for the standard version, and no greater than 10° for the high ceiling mount version.
- Avoid direct Infrared LED light in the detection area.
- Not suggested to install the sensor close to glass or mirror.
- Ensure that no other objects are blocking the ToF light within a 50cm radius of the device’s field of view.
- Though the device is compliant with Class 1 (IEC/EN 60825-1:2014), please DO NOT look at the ToF sensor too closely and directly.
- Avoid installing the device against the wall and ensure the device keeps away from the wall with a distance of at least 40cm.
- When you install devices on the top of swinging doors, it is suggested to keep the door normally open. If the door must be normally closed, please install the device on the other side of the door to keep away from the door’s movement. And it is suggested to keep away from the door with a distance of at least 40cm.
Access the Web GUI
VS135 provides a user-friendly web GUI for configuration access via Wi-Fi or
Ethernet port. Users need to customize the password when using the device for
the first time.
The default settings are as below:
- Wi-Fi SSID: People Counter_xxxxxx (can be found on the device label)
- Wi-Fi IP: 192.168.1.1
- Ethernet IP: 192.168.5.220 (PoE Version Only)
Here are 2 ways of accessing the web GUI:
- Wireless Method: Enable the Wireless Network Connection on your computer, search for the corresponding Wi-Fi SSID to connect it, and then type 192.168.1.1 to access the web GUI.
- Wired Method: Connect the device to the computer via an Ethernet port, and assign the IP address of the computer to 192.168.5.xxx manually, then type 192.168.5.220 to access the web GUI.
FCC Statement
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and.
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator& your body. This transmitter
must not be co-located or operating in conjunction with any other antenna or
transmitter.
SCANNER
All Software & files can be downloaded from
https://www.milesight.com/iot/resources/download-center/#documents
Better Inside, More in Sight
Xiamen Milesight loT Co., Ltd. www.milesight.com
Add: BuildingC09,SoftwareParkPhasellI,Xiamen361024,
Fujian, China
FAQ
Q: How do I troubleshoot if the product does not turn on?
A: Check the power source connection and ensure it is properly plugged in. If the issue persists, contact customer support.
Q: Can I disassemble the product for cleaning?
A: It is not recommended to disassemble the product for cleaning. Use a damp cloth for surface cleaning.