Milesight WS50x LoRaWAN Wall Switch User Guide

June 3, 2024
Milesight

Milesight -logo WS50x LoRaWAN Wall Switch
User Guide

Safety Precautions

Milesight will not shoulder responsibility for any losses or damages resulting from not following the instructions of this operating guide.

  • The installation and maintenance must be conducted by a qualified service person and should strictly comply with the electrical safety regulations of the local region.
  • Ensure the breaker is power out during the installation.
  • Do not leave any object inside the switch box when installation.
  • The device must not be modified in any way.
  • In order to protect the security of the device, please change the device password when first configuration. The default password is 123456.
  • In order to realize the best data transmission, ensure the device is within the signal range of the LoRaWAN® gateway and keep it away from metal objects and obstacles.
  • Do not overload the maximum capacity to avoid damaging the device.
  • The device is intended for indoor use only. Do not place the device where the temperature is below/above the operating range.
  • Do not place the device close to naked flames, heat source (such as oven or sunlight), cold source, liquid, and objects with extreme temperature changes.
  • Use the device in a clean environment only. Dusty or dirty environments may prevent the proper operation of this device.
  • The device must never be subjected to physical shocks or strong vibration.

Declaration of Conformity
WS50x is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.

Copyright © 2011-2022 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means without written authorization from Xiamen Milesight IoT Co., Ltd.

For assistance, please contact Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: Building C09, Software Park III,
Xiamen 361024, China

Revision History

Date Doc Version Description
June 24, 2022 V 1.0 Initial version

Product Introduction

1.1 Overview

WS50x is a smart LoRaWAN® wall switch for the local and remote control of lights and electrical appliances. It adopts two standard sizes for most of international wall switch types, which can replace the traditional wall switches directly. Compliant with Milesight LoRaWAN ® gateway and Milesight IoT Cloud solution, WS50x can be monitored and controlled via web page or mobile App remotely and triggered by other Milesight sensors. Besides LoRaWAN ® , WS50x supports Milesight LoRa D2D communication protocol, which can set up connection quickly and be controlled without gateway. WS50x can be widely used for wireless control of indoor lights, fans, heaters, machines, etc.

1.2 Features

  • Support local or remote control via a relay with high reliability
  • Support surge protection, and overload protection to prevent the device from damage
  • Collect data of current, voltage, power, and electrical consumption
  • Built-in switch indicator for easy use in dark environment
  • Up to 15 km communication range
  • Easy configuration via NFC
  • Standard LoRaWAN® technology
  • Compatible with Milesight IoT Cloud
  • Support Milesight LoRa D2D protocol to enable ultra-low latency control without gateway
  • Support multicast for control in bulk

Hardware Introduction

2.1 Packing List

Milesight WS50x LoRaWAN Wall Switch-

If any of the above items is missing or damaged, please contact your sales representative.

2.2 Hardware Overview

Milesight WS50x LoRaWAN Wall Switch-fig1

2.3 Dimensions (mm)

Milesight WS50x LoRaWAN Wall Switch-fig2

2.4 Wiring Diagram

Milesight WS50x LoRaWAN Wall Switch-fig3

Installation

  1. Ensure the circuit has been shut off and the old switch has been taken off.

  2. Open the front panel of WS50x switch.
    Milesight WS50x LoRaWAN Wall Switch-fig4

  3. Connect corresponding wires to the WS50x switch.

  4. Fix the WS50x switch to the switch box with mounting screws, then fix the front panel back to the device.
    Milesight WS50x LoRaWAN Wall Switch-fig6

Operation Guide

4.1 NFC Configuration
WS50x can be configured via an NFC supported mobile phone.

  1. Download and install “Milesight ToolBox” App from Google Play or Apple App Store.

  2. Enable NFC on the smartphone and open Milesight ToolBox.

  3. Attach the smartphone to NFC area of the switch to read device information.
    Milesight WS50x LoRaWAN Wall Switch-fig7

  4. Basic information and settings of WS50x switch will be shown on the ToolBox if it’s recognized successfully. You can read and configure the device by tapping the Read/Write button on the App. In order to protect the security of devices, password validation is required when first configuration. The default password is 123456.

Note:

  1. Ensure where is the NFC area on your smartphone, and it’s recommended to take off the phone case.
  2. If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again.
  3. WS50x can also be configured by ToolBox software via a dedicated NFC reader provided by Milesight IoT.

4.2 LoRaWAN Settings

LoRaWAN settings are used to configure the data transmission parameters in the LoRaWAN® network.
4.2.1 Basic Settings
WS50x supports basic configurations like join type, App EUI, App Key and other information. You can also keep all settings unchanged by default.

Milesight WS50x LoRaWAN Wall Switch-fig8

Parameters Description
Device EUI Unique ID of the device which can also be found on the label.
App EUI Default App EUI is 24E124C0002A0001.
Application Port The port used for sending and receiving data, the default

port is 85.
Join Type| OTAA and ABP modes are both available.
Application Key| Appkey for OTAA mode is default as 5572404C696E6B4C6F52613230313823.
Device Address| DevAddr for ABP mode is default as the 5th to 12 th digits of SN.
Network Session Key| Nwkskey for ABP mode is default as 5572404C696E6B4C6F52613230313823.
Application Session Key| Appskey for ABP mode is default as 5572404C696E6B4C6F52613230313823.
LoRaWAN Version| V1.0.2 and V1.1.0 are available.
Work Mode| This device supports Class C only.
RX2 Data Rate| RX2 data rate to receive downlinks or LoRa D2D commands.
RX2 Frequency/MHz| RX2 frequency to receive downlinks or LoRa D2D commands.
Confirmed Mode| If the device does not receive ACK packet from network server, it will resend data once.
Rejoin Mode| The device will send a specific number of LinkChecker MAC packets to the network server every 30 mins to validate connectivity; If there is no response, the device will re-join the network.
ADR Mode| Allow the network server to adjust the data transmission rate of the device.
Spread Factor| If ADR is disabled, the device will send data via this spread factor.
Tx Power| Transmit power of the device.

Note:

  1. Please contact sales representative for device EUI list if there are many units.
  2. Please contact sales representative if you need random App keys before purchase.
  3. Select OTAA mode if you use Milesight IoT Cloud to manage devices.
  4. Only OTAA mode supports rejoin mode.

4.2.2 Frequency Settings
Select supported frequency and channels to send uplinks. Make sure the channels match the LoRaWAN ® gateway.

If device frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas. Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60
All: Enabling all channels
Null: Indicates that all channels are disabled

Milesight WS50x LoRaWAN Wall Switch-fig10

Note:
For -868M model, the default frequency is EU868;
For -915M model, the default frequency is AU915.

4.2.3 Multicast Settings
WS50x supports setting up several multicast groups to receive multicast commands from the network server ,then users can use this feature to control devices in bulks.

  1. Enable Multicast Group on WS50x, and set a unique multicast address and keys to distinguish other groups. You can also keep these settings by default.Milesight WS50x LoRaWAN Wall Switch-fig11
    Parameters| Description
    ---|---
    Multicast Address| Unique 8-digit address to distinguish different multicast groups.
    Multicast McNetSkey| 32-digit key. Default values:
    Multicast Group 1: 5572404C696E6B4C6F52613230313823
    Multicast Group 2: 5572404C696E6B4C6F52613230313824
    Multicast Group 3: 5572404C696E6B4C6F52613230313825
    Multicast Group 4: 5572404C696E6B4C6F52613230313826
    Multicast Mac AppSkey| 32-digit key. Default values:
    Multicast Group 1: 5572404C696E6B4C6F52613230313823
    Multicast Group 2: 5572404C696E6B4C6F52613230313824
    Multicast Group 3: 5572404C696E6B4C6F52613230313825
    Multicast Group 4: 5572404C696E6B4C6F52613230313826
  2. Add a multicast group on the network server. Take Milesight UG6x gateway as example, go to “Network Server -> Multicast Groups”, click “Add” to add a multicast group.Milesight WS50x LoRaWAN Wall Switch-fig12Fill in the multicast group information the same as WS50x settings, and select the devices which you need to control, then click “Save”.Milesight WS50x LoRaWAN Wall Switch-fig13
  3. Go to “Network Server -> Packets”, select the multicast group and fill in the downlink command, click “Send”. The network server will broadcast the command to devices that belong to this multicast group.
    Note: ensure all devices’ application ports are the same.Milesight
WS50x LoRaWAN Wall Switch-fig14

4.3 General Settings

Parameters Description
Reporting Interval The interval of reporting switch status and electrical

parameters.
Default: 20 mins, Range: 1 – 1080 mins
LED Indicator| Enable or disable the light of switch button. This will not affect the blinks when you hold on switch buttons to reset the device.
Power Consumption| Record the power consumption. If disabled, the device will stop recording and the power consumption value will stop updating.
When Power is Restored| If the device is powered off and restored, the device will change according to this parameter.
Button Lock| If enabled, all switch buttons will not be allowed to turn on/off or reset to factory default.
Change Password| Change the password for ToolBox App to write this device.

4.4 LoRa D2D Settings
LoRa D2D protocol is developed by Milesight and used for connection among Milesight devices without gateway. When LoRa D2D setting is enabled, WS50x can work as the LoRa D2D agent device to receive commands from LoRa D2D controller devices.

  1. Ensure the RX2 data rate and RX2 frequency in LoRaWAN settings are the same as the LoRa D2D controller device.

  2. Enable LoRa D2D feature, and define a unique LoRa D2D key to be the same as the setting in LoRa D2D controller device.
    (Default LoRa D2D Key: 5572404C696E6B4C6F52613230313823)

  3. Define a 2-byte hexadecimal control command (0x0000 to 0xffff) and command action. For example, you can configure a control command 12ff to turn on any button as below. WS50x supports at most 16 control commands.Milesight WS50x LoRaWAN Wall Switch-fig16

  4. These control commands can be configured in LoRa D2D controller device. When LoRa D2D controller device is triggered, it will send the pre-defined control commands to control the switches of WS50x to on, off or inverse status.

4.5 Maintenance
4.5.1 Upgrade

  1. Download firmware from www.milesight-iot.com to your smartphone.
  2. Open ToolBox App and click “Browse” to import firmware and upgrade the device.

Note:

  1. Operation on ToolBox is not supported during the upgrade.
  2. Only Android version ToolBox supports the upgrade feature.

4.5.2 Backup
WS50x supports configuration backup for easy and quick device configuration in bulk. Backup is allowed only for devices with the same model and LoRaWAN® frequency band.

  1. Go to “Template” page on the App and save current settings as a template. You can also edit the template file.
  2. Select one template file that saved in the smartphone and click “Write”, then attach it to another device to write configuration.Milesight WS50x LoRaWAN Wall Switch-fig18 Note: Slide the template item to the left to edit or delete it. Click the template to edit the configurations.

4.5.3 Reset to Factory Default
Please select one of the following methods to reset the device:
Via Hardware: Hold on the button for more than 10s until button light blinks, this should ensure the button lock is disabled.
Via ToolBox App: Go to Device -> Maintenance to tap “Reset”, then attach smartphone with NFC area to the device to complete the reset.Milesight WS50x
LoRaWAN Wall Switch-fig20

Device Payload

All data are based on the following format (HEX), the Data field should follow little -endian:

Channel1| Type1| Data1| Channel2| Type2| Data2| Channel 3|
---|---|---|---|---|---|---|---
1 Byte| 1 Byte| N Bytes| 1 Byte| 1 Byte| M Bytes| 1 Byte| …

For decoder examples you can find at https://github.com/Milesight- IoT/SensorDecoders.

5.1 Basic Information
WS50x reports basic information of the device whenever it joins the network.

Channel Type Description
ff 01(Protocol Version) 11=>V1.1
09 (Hardware Version) 01 40 => V1.4
0a (Software Version) 01 14 => V1.14
0b (Power On) Device is on
16 (Serial Number) Serial number of this device, 16 digits

Example:

ff0bff ff0101 ff090100 ff0a0101 ff166771c21070911328

Channel| Type| Value| Channel| Type| Value
ff| 0b (Power On)| ff (Reserved)| ff| 01 (Protocol Version)| 01(V1.0)
Channel| Type| Value| Channel| Type| Value
ff| 09 (Hardware Version)| 0100 (V1.0)| ff| 0a (Software Version)| 0101 (V1.1)
Channel| Type| Value| | |
ff| 16 (Serial Number)| 6771c21070 911328| | |

5.2 Sensor Data
WS50x reports switch status and electrical data according to reporting interval (20 mins by default). Besides, when any switch status changes, the device will upload the switch status immediately.

Channel Type Description
03 74 (Voltage) UINT16, Unit: V

Resolution: 0.1 V
04| 80 (Active Power)| UINT32, Unit: W
05| 81 (Power Factor)| UINT8, Unit: %
06| 83 (Power Consumption)| UINT32, Unit: Wh
---|---|---
07| c9 (Total Current)| UINT16, Unit: mA
08| 29 (Switch Status)| Bit 0: status of switch 1
Bit 1: status of switch 2
Bit 2: status of switch 3
Bit 3: reserved
Bit 4: changing status of switch 1 Bit 5: changing status of switch 2 Bit 6: changing status of switch 3 Bit 7: reserved

Example:

082913 058164 07c90200 0374b208 068301000000 048001000000

Channel| Type| Value| Channel| Type| Value
08| 29 (Switch Status)| 13= 00010011 => switch 1 changed to open, switch 2 remains opened| 05| 81 (Power Factor)| 64=> 100%
Channel| Type| Value| Channel| Type| Value
07| c9 (Current)| 02 00=>00 02=2mA| 03| 74(Voltage)| b2 08=>08
b2=2226
Voltage=2226
*0.1=222.6V
Channel| Type| Value| Channel| Type| Value
06| 83(Power Consumption)| 01 00 00 00=>00
00 00 01=1
Wh=0.001 kWh| 04| 80 (Active Power)| 01 00 00
00=>00 00 00
01=1 W

5.3 Downlink Commands
WS50x supports downlink commands to configure the device. The application port is 85 by default.

Channel Type Description
08 **Byte 1:

Bit 0~3: every switch control status, 0 for close, 1 for open.
Bit 4~7: every switch change status, 0 = not allow control, 1 = allow control
Byte 2: ff
ff| 03 (Set Reporting Interval)| 2 Bytes, unit: s
---|---|---
10 (Reboot Device)| ff
22 (Add Delay Task)|
Byte 1: 00
Byte 2-3: delay time, unit: s
Byte 4:
Bit 0~3: desired status for each switch. Bit 4~7: mask of switches to change, only masked switch will be changed to desired status.
Note:** WS50x supports adding only one task.
Later command will cover previous command.
23 (Delete Delay Task)| 00 ff
25 (Set Button On/Off Lock)| 0080-disable to turn on/off via button,
0000-enable to turn on/off via button
26 (Power Consumption)| 00-disable, 01-enable
27 (Reset Power Consumption)| ff
28 (Enquire Electrical Status)| ff
2f (Set Button Light Mode)| 00- disable
01- enable (Button light indicator on when switch button is off)
02- enable (Button light indicator on when switch button is on)
5e (Set Button Reset Lock)| 00-enable to reset via button, 01-disable to reset via button

Example:

  1. Close Switch 1 of WS501, WS502, WS503.
    0810ff

    Channel| Type| Command
    08| –| Byte 1: 10 => 0001 0000 (Bit 4 = 1 => Allow switch 1 control, Bit0 = 0 => Switch 1 close)
    Byte 2: ff is reserved

  2. Set reporting interval as 20 minutes.
    ff03b004

    Channel| Type| Value
    ff| 03 (Set Reporting Interval)| b0 04 => 04 b0 = 1200 s = 20 minutes

  3. Add a delay task: open switch 1 after 1 minute.
    ff32003c002000

    Channel| Type| Value
    ff| 22 (Add Delay Task)| Byte 1:00
    Byte 2-3: 3c 00 => 00 3c = 60 s = 1 min
    Byte 4: 11 = 0001 0001 => Open switch 1

  4. Delete the delay task
    ff2300ff

    Channel| Type| Value
    ff| 23 (Delete Delay Task)| 00ff

  5. Disable the collection and upload of power consumption.
    ff2600

    Channel| Type| Value
    ff| 26 (Power Consumption)| 00 = disable

  6. Reboot the device.
    ff10ff

    Channel| Type| Value
    ff| 10 (Reboot Device)| ff (Reserved)

  7. Disable button light.
    ff2f00

    Channel| Type| Value
    ff| 2f (Set LED Indicator Mode)| 00 for disable LED indicator

-END-

14 rue Edouard Petit
F42000 Saint-Etienne
ATTENTION – NOUVELLE ADRESSE
Tel: +33 (0) 477 92 03 56 Fax: +33 (0) 477 92 03 57
Remy GUEDOT
Gsm: +33 (0) 662 80 65 57
guedot@rg2i.fr
Olivier BENAS Gsm:
+33 (0) 666 84 26 26
olivier.benas@rg2i.fr
www.rg2i.fr

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>