Milesight EM320-TILT LoRaWAN Tilt Sensor
Product Information
The EM320-TILT is a tilt sensor that is used to measure the angle of an object with respect to gravity. The device is designed to provide accurate and reliable readings, and it comes with anumber of safety precautions that must be followed to ensure proper usage.
Safety Precautions
- Do not disassemble or remodel the device in any way.
- Change the device password when first configuring it to protect its security. The default password is 123456.
- Do not place the device close to objects with naked flames.
- Do not place the device where the temperature is below/above the operating range.
- The device is not intended to be used as a reference sensor, and damage may result from inaccurate readings.
- Remove the battery from the device if it is not to be used for an extended period to prevent battery leakage and damage to the device.
- Make sure all batteries are new when installing, or battery life will be reduced.
- The device must never be subjected to shocks or impacts.
Declaration of Conformity
The EM320-TILT is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.
Contact Information
- Email: iot.support@milesight.com
- Support portal : support.milesight-iot.com
- Tel : 86-592-5085280
- Fax : 86-592-5023065
- Address : Building C09, Software Park III, Xiamen 361024, China
Product Usage Instructions
Installation
Before installing the EM320-TILT, ensure that all the items in the packing list are present and undamaged. If any item is missing or damaged, contact your sales representative. Follow these steps to install the device:
- Choose a suitable location for the device.
- Mount the device on a stable surface using the provided mounting hardware.
- Connect the device to a power source using the provided cable.
Device Payload
The EM320-TILT provides basic information, sensor data, and downlink commands. Follow these steps to access the device payload:
- Connect to the device using a compatible device or software.
- Select the desired payload type.
- View the payload data.
Note : Consult the user manual or contact technical support for more detailed instructions on accessing the device payload.
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.
- The device must not be disassembled or remodeled in any way.
- In order to protect the security of the device, please change device password when first configuration. The default password is 123456.
- Do not place the device close to objects with naked flames.
- Do not place the device where the temperature is below/above the operating range.
- The device is not intended to be used as a reference sensor, and Milesight will not should responsibility for any damage which may result from inaccurate readings.
- The battery should be removed from the device if it is not to be used for an extended period. Otherwise, the battery might leak and damage the device. Never leave a discharged battery in the battery compartment.
- Make sure all batteries are newest when install, or battery life will be reduced.
- The device must never be subjected to shocks or impacts.
Declaration of Conformity
EM320-TILT is in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.
Copyright © 2011-2023 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no
organization or individual shall copy or reproduce the whole or part of this
user guide by any means without written authorization from Xiamen Milesight
IoT Co., Ltd.
For assistance, please contact Milesight technical support:
Email: iot.support@milesight.com
Support portal: support.milesight-iot.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: Building C09, Software Park III,
Revision History
Date | Doc Version | Description |
---|---|---|
Feb.14, 2023 | V 1.0 | Initial version |
Product Introduction
Overview
EM320-TILT is an LoRaWAN® tilt sensor mainly for angle measurement and asset
movement detection. With a compact size and 3-axis accelerometer, EM320-TILT
can be installed to the objects easily to measure its X,Y,Z tilt angles. In
addition, EM320-TILT supports customizing initial position to detect movement
based on angle changes and send threshold alarms. Compliant with Milesight
LoRaWAN® gateway and Milesight IoT Cloud solution, users can know the angles
and tilt threshold alarms in real-time via browser or mobile app remotely.
EM320-TILT can be widely used in tree monitoring, pole lean detection,
landslide monitoring, etc.
Features
- Built-in MEMS accelerometer sensor to measure the 3-axis angles of any objects
- Flexible threshold condition settings, suitable for different kinds of applications
- Easy to install, suitable for various types of objects as trees, poles, grounds, etc.
- IP67 waterproof enclosure for outdoor applications
- Anti-theft design on back cover to secure firm and sturdy installation
- Ultra-wide-distance wireless transmission up to line of sight of 15km
- Equipped with NFC for one touch configuration
- Function well with standard LoRaWAN® gateways and network servers
- Compliant with Milesight IoT Cloud
Hardware Introduction
Packing List
If any of the above items is missing or damaged, please contact your sales Representative.
Hardware Overview
When you install EM320-TILT on site, below is the angle number you can expect with corresponding device gesture.
Dimensions(mm)
Power Button
The LED indicator and power button are inside the device. Switch on/off and
reset can also be configured via NFC.
Function | Action | LED Indication |
---|---|---|
Turn On | Press and hold the button for more than 3 seconds. | Off → On |
Turn Off | Press and hold the button for more than 3 seconds. | On → Off |
Reset | Press and hold the button for more than 10 seconds. | Blink 3 times. |
Check
On/Off Status
|
Quickly press the power button.
| Light On: Device is on.
Light Off: Device is off.
Operation Guide
NFC Configuration
EM320-TILT sensor can be monitored and configured via NFC. Please refer the
following steps to complete the configuration.
- Download and install “Milesight ToolBox” App from Google Play or Apple App Store.
- Enable NFC on the smartphone and launch Milesight ToolBox.
- Attach the smartphone with NFC area to the device to read device information. Basic information and settings of the device will be shown on ToolBox App if it’s recognized successfully. You can read and configure the device by tapping the Read/Write device on the App. In order to protect the security of the device, please change the password when first configuring. The default password is 123456.
Note:
- Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
- If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again.
- EM320-TILT sensor can also be configured by dedicated NFC reader, which can be purchased from Milesight IoT.
LoRaWAN Settings
LoRaWAN settings is used for configuring the transmission parameters in
LoRaWAN® network.
Basic LoRaWAN Settings:
Go to Device > Settings > LoRaWAN Settings of ToolBox App to configure join
type, App EUI, App Key and other information. You can also keep all settings
by default.
Parameters | Description |
---|---|
Device EUI | Unique ID of the device which can also be found on the label. |
App EUI | Default App EUI is 24E124C0002A0001. |
--- | --- |
Application Port | The port is used for sending and receiving data, default |
port is 85.
Join Type| OTAA and ABP mode are available.
Application Key| Appkey for OTAA mode, default is
5572404C696E6B4C6F52613230313823.
Device Address| DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Network Session
Key
|
Nwkskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Application Session Key|
Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
LoRaWAN Version| V1.0.2, V1.0.3 are available.
Work Mode| It’s fixed as Class A.
RX2 Data Rate| RX2 data rate to receive downlinks.
RX2 Frequency| RX2 frequency to receive downlinks. Unit: Hz
Spread Factor| If ADR is disabled, the device will send data via this spread
factor.
Confirmed Mode
| If the device does not receive ACK packet from network server, it will resend
data once.
Rejoin Mode
| Reporting interval ≤ 30 mins: the device will send a specific number of LinkCheckReq MAC packets to the network server every 30 mins to validate connectivity; If there is no response, the device will re-join the network.
Reporting interval > 30 mins: the device will send a specific number of LinkCheckReq MAC packets to the network server every reporting interval to validate connectivity; If there is no response, the device will re-join the
network.
Set the number of packets sent|
When rejoin mode is enabled, set the number of LinkCheckReq packets sent.
ADR Mode| Allow network server to adjust data rate of the device.
Tx Power| Transmit power of the device.
Note:
- Please contact sales for device EUI list if there are many units.
- Please contact sales if you need random App keys before purchase.
- Select OTAA mode if you use Milesight IoT cloud to manage devices.
- Only OTAA mode supports rejoin mode.
LoRaWAN Frequency Settings:
Go to Settings > LoRaWAN Settings to select supported frequency and select
channels to send uplinks. Make sure the channels match the LoRaWAN® gateway.
If frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas.
Examples:
- 1, 40: Enabling Channel 1 and Channel 40
- 1-40: Enabling Channel 1 to Channel 40
- 1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60
All : Enabling all channels
Null : Indicates that all channels are disabled
Basic Settings
Go to Device > Settings > General Settings to change the reporting interval,
etc.
Parameters | Description |
---|
Reporting Interval
| Reporting interval of transmitting current sensor values to network
server. Default: 1080 mins, Range: 1-1080 mins
Change Password
| Change the password for ToolBox App or software to read/write this
device.
Threshold Settings
Go to Device > Settings > Threshold Settings to enable the threshold settings and input the angle threshold. You can set a relative initial surface to measure the deviance from an initial one and if the device detects the angle of a certain axis reaches the threshold based on the initial position, it will upload the current data instantly.
Parameters | Description |
---|
Initial Position
| Click Setting to set current position of device as initial position to measure the deflection angle.
Click Clear to change the initial position back to (0.00°, 0.00°, -90.00°).
Note: after writing Setting or Clear configuration, click Read to read the device to check if the initial position changes successfully.
Over / °| The maximum/upper limit of angle threshold.
Below / °| The minimum/lower limit of angle threshold.
Alarm Condition
| Acceptable elements are “X”, “Y”, “Z”, “and”, “or” “only”, it takes 2 or 3 axes to complete an expression and the device will only read from left to right. If left blank, it will consider the condition as “or”.
Example:
1) XandYorZ means (X and Y) or Z, that is XandY meets the threshold or Z meets the threshold.
2) XorYandZ means (X or Y) and Z, that is XandZ meets the threshold or YorZ
meets the threshold.
Alarm Reporting Interval| After the threshold is triggered, the device will detect if the threshold is triggered again according to this reporting interval.
Alarm Reporting Times
| After the threshold is triggered, the device will detect according to Alarm
Reporting Interval and if still triggered, the device will send the certain number of alarms to NS.
Example:
When X axis is detected to 0° (0° – 1.91° = -1.91° < -1°), it will trigger the
threshold and upload an alarm package right away. If it changes back to
normal, the device will also upload a data package immediately; if not, it
will send alarm package after 1 minute. This process will repeat 2 times
.
Maintenance
Upgrade
- Download firmware from www.milesight-iot.com to your smartphone.
- Open ToolBox App and click Browse to import firmware and upgrade the device.
Note:
- Operation on ToolBox is not supported during the upgrade.
- Only Android version ToolBox supports the upgrade feature.
Backup
EM320-TILT sensor supports configuration backup for easy and quick device
configuration in bulk. Backup is allowed only for devices with the same model
and LoRaWAN® frequency band.
- Go to Template page on the App and save current settings as a template. You can also edit the template file.
- Select one template file that saved in the smartphone and click Write, then attach it to another device to write the configuration.
Note : Slide the template item to the left to edit or delete it. Click the template to edit the configurations.
Reset to Factory Default
Please select one of following methods to reset device:
- Via Hardware: Hold on reset button inside the device more than 10s.
- Via ToolBox App: Go to Device > Maintenance > Reset to click Reset, then attach the smartphone with NFC area to the device to complete reset.
Installation
- Remove the backplate on the back of the device, screw the wall plugs into the wall and fix the backplate with screws on it, then install back the device. Note that the vent of device should not face upwards when installing.
- Fix the bottom of the device to the cover with a fixing screw.
Installation Location:
- Ensure the location of device is within the communication range of LoRaWAN® gateway and keep it away from metal objects.
- Ensure that the device is tightly attached without any gap to the surface to be measured of a certain object, and one of the 3 axes should be paralleled with the measuring axis of the object, otherwise, the result may not be correct.
Device Payload
All data are based on following format (HEX), the Data field should follow little-endian:
Channel1 | Type1 | Data1 | Channel2 | Type2 | Data2 | Channel 3 | … |
---|---|---|---|---|---|---|---|
1 Byte | 1 Byte | N Bytes | 1 Byte | 1 Byte | M Bytes | 1 Byte | … |
For decoder examples please find files on https://github.com/Milesight- IoT/SensorDecoders.
Basic Information
EM320-TILT sensors report basic information of sensor whenever joining the
network.
Channel | Type | Description |
---|
ff
| 01(Protocol Version)| 01=>V1
09 (Hardware Version)| 01 40 => V1.4
0a (Software Version)| 01 14 => V1.14
| 0b (Power On)| Device is on
---|---|---
0f (Device Type)| 00: Class A, 01: Class B, 02: Class C
16 (Device SN)| 16 digits
Example:
ff0bff ff0101 ff166785c38144050018 ff090110 ff0a0101 ff0f00
Channel| Type| Value| Channel| Type| Value
ff| 0b
(Power On)
| ff
(Reserved)
| ff| 01
(Protocol Version)
| 01
(V1.0)
Channel| Type| Value| Channel| Type| Value
ff| 16
(Device SN)
| 6785c381440
50018
| ff| 09
(Hardware version)
| 0110
(V1.1)
Channel| Type| Value| Channel| Type| Value
ff
| 0a (Software
version)
| 0101 (V1.1)|
ff
| 0f (Device Type)| 00
(Class A)
Sensor Data
EM320-TILT sensors report sensor data according to reporting interval
(1080mins by default).
Item | Channel | Type | Description |
---|---|---|---|
Battery Level | 01 | 75 | UINT8, Unit: % |
Angle
|
03
|
d4
| 6 Bytes, INT16
angle_x (2B) + angle_y(2B) + angle_z(2B), Unit:°, Resolution: 0.01°
angle_x bit0: 0-normal; 1-trigger angle_y bit0: 0-normal; 1-trigger
angle-z bit0: 0-normal; 1-trigger
Example:
017564 03d498fd 44ff 6b22
Channel| Type| Value| Channel| Type| Value
| | | | | X: 98 fd => fd 98
| | | | | = (-616-0)/2 * 0.01
01
| 75
(Battery Level)
|
64=>100%
|
03
| d4 (Angle)| = -3.08°
Y: 44 ff => ff 44
| | | | | = (-188-0)/2 * 0.01
| | | | | = -0.94°
| | | | | Z: 6b 22 => 22 6b
= (8811-1)/2 * 0.01
= 44.05°
X=fd 98 => 1111 1101
1001 1000
X_bit0: 0 => normal Y_bit0: 0 => normal Z_bit0: 1 => trigger
---|---|---|---|---|---
Downlink Commands
EM320-TILT sensors support downlink commands to configure the device. The
application port is 85 by default.
Channel | Type | Description |
---|
ff
| 03 (Set Reporting Interval)| 2 Bytes, unit: s
06 (Set Threshold)
| 9 Bytes:
Threshold Type(1B) + Min Threshold (2B) + Max Threshold (2B)+ Alarm Reporting Interval (2B) + Alarm Reporting Time (2B)
Threshold Type: Bit0~Bit2:
00- disable
01- below (minimum threshold) 010-over (maximum threshold) 011-within
100-below or above Bit3: X-axis angle Bit4: Y-axis angle Bit5: Z-axis angle
Bit6~Bit7: Reserved
10 (Reboot)| ff (Reserved)
|
62 (Set Initial Position)
| ff: set current position as initial position
fe: set the initial position to (0.00°, 0.00°, -90.00°)
|
63 (Set Alarm Condition)
| 8 Bytes, hex string of ASCII expression; if ASCII
expression takes less than 8 bytes, add 0 in the
| | end to meet the size.
Note: before setting the condition, ensure the corresponding axis threshold is enabled, or this
condition will not work
---|---|---
Example:
-
Set reporting interval as 20 minutes.
ff03b004Channel| Type| Value
ff| 03 (Set Reporting Interval)| b0 04=>04 b0=1200s =20 minutes -
Set X-axis threshold between 10° and 20°, it will detect the threshold every 1 minute, send alarm 3 times at most.
ff060ce803d0073c000300Channel| Type| Value
ff
|
06 (Set Threshold)
| 0c => 00 001 100 = when X axis angle is below or above,
e803 => 1000 = 10.00°
d007 => 2000 = 20.00°
3c00 => 60 s = 1 min 0300 => 00 03 = 3 times
-
Reboot the device.
ff10ffChannel| Type| Value
ff| 10 (Reboot)| ff (Reserved) -
Set the alarm condition to be X and Y or Z, before setting ensure X, Y and Z thresholds are enabled.
ff635826597c5a0000Channel| Type| Value
ff| 63 (Set Alarm Condition)| 5826597c5a0000 = X&Y|Z -
Set current position as initial position.
ff62ffChannel| Type| Value
ff| 62 (Set Initial Position)| ff = set current position as initial position