Johnson Controls IQ Keypad Battery Powered Instruction Manual
- May 15, 2024
- Johnson Controls
Table of Contents
INSTALLATION MANUAL
IQ Keypad-PG
IQ Keypad Prox-PG
IQ Keypad is a battery powered, capacitive touch keypad for use with
compatible IQ4 NS, IQ4 Hub & IQ Panel 4 platforms via the PowerG protocol. It
provides an easy and intuitive interface to control basic features of the
system.
This manual covers both IQ Keypad-PG and IQ Keypad Prox-PG models.
INTRODUCTION
INCLUDED IN BOX ABOUT THIS GUIDE
This document outlines the basic hardware specifications and software
directions to install and customize the IQ Keypad. Note that the information
presented is not comprehensive, but is specifically dedicated to those menus,
features, and systems accessible solely to those with the proper installation
code. Features accessible to users and installers alike are outlined in the IQ
Keypad User Guide. The information contained is confidential and proprietary,
and is solely owned by Qolsys Inc. Any reproduction, modification or
distribution without permission is strictly prohibited. Reference to IQ Keypad
throughout this manual covers both models IQ Keypad-PG and IQ Keypad Prox-PG
unless stated differently.
SUPPORT
QUESTIONS?
Contact us at
intrusion-support@jci.com
QOLSYS CONFIDENTIAL AND PROPRIETARY
IQ KEYPAD OVERVIEW
Warning: This Product should be installed in accordance with the National Fire
Alarm Code, ANSI/NFPA 72, (National Fire Protection Association, Batterymarch
Park,Quincy, MA 02269) and with National Electric Code, ANSI/NFPA 70. Printed
information describing proper installation, operation, testing, maintenance,
evacuation planning, and repair service is to be provided with this Product.
In Canada the product shall be installed in accordance with the Standard for
the Installation of Residential Fire Warning Systems, CAN/ULC-S540.
Warning: For Canadian installations this Product and all sensors associated
with it (collectively, the “System”) should be tested once a week. The test
shall be performed also with primary DC power de-energized. For recommended
smoke detectors maintenance instructions refer to user manual associated with
compatible Qolsys model QS5110-P840 smoke detector.
EXTERIOR FRONT EXTERIOR BACK
INSTALLING IQ KEYPAD
WALL MOUNT
Note: For UL/ULC Commercial Burg installations (UL2610/ULC-S304
Security Level II compliant) use only wall mount option.
This product when installed as per these instructions does not present the
risk of fire, electric shock, or injury to persons.
-
Mount the bracket to the wall using appropriate hardware ensuring it is level.
-
A screw shall be used in this hole for UL2610 installations
-
Insert the 4 x AA batteries in to the battery slots.
Be sure to observe correct polarity.
Use only Energizer AA 1.5V ALKALINE BATTERY -
Slide the keypad down onto the wall mount and secure with the bottom screw so that it can not be removed.
ENROLLING THE IQ KEYPAD
The IQ Keypad can be paired to either an IQ4 NS, IQ4 Hub or IQ Panel 4 running
software version 4.4.0 or higher using the PowerG protocol. Panels that do not
have the PowerG daughter card installed will not support the IQ Keypad. Follow
the instructions below to pair an IQ Keypad to the primary panel:
- On the primary panel, start the “Auto Learn” process as indicated in the primary panel manual (Settings/Advanced Settings/Installation/Devices/Security Sensors/Auto Learn Sensor).
- On the IQ Keypad press and hold for 3 seconds to initiate pairing.
- The IQ Keypad will be recognized by the primary panel. Configure options accordingly then touch “Add New”.
NOTE: The IQ Keypad may also be manually paired to a panel by using the sensor ID printed on the device beginning with 372-XXXX. If manual learn is used instead of Auto Learn, you must network the device after pairing is complete by pressing and holding [*] for 3 seconds.
USER INTERFACE
STATUS LIGHTS
KEYPAD STATUS LIGHTS:
Status lights help you understand the state of the system at a glance.
Status Lights | LED | Description |
---|---|---|
OFF | Not ready to Arm. | |
ON | Ready to Arm. | |
FLASHING | Ready to Arm, bypass-able zones are open. | |
OFF | Disarmed | |
ON | Armed | |
FLASHING | Alarm occurred | |
RAPID FLASHING | Bell silenced for Fire Alarms | |
OFF | No Trouble | |
ON | System Trouble | |
FLASHING | Keypad Low Battery |
ARMING
ARMING KEYS:
Arming keys are the primary way of controlling the system from the IQ Keypad.
Key | Description |
---|---|
Arm Stay | |
Arm Away | |
Arm Night |
NOTE: If successful, the Armed Status LED will flash twice. If
communication is not successful, the keypad flashes all keypad number LED’s
(backlight) 0.5 seconds ON/OFF twice.
SECURE ARMING:
When Secure Arming is enabled on the primary panel, a valid 4 – 6 digit users
code is required to Arm the system.
Key | Description |
---|---|
Arm Stay + [Access Code] or [Prox Tag] | |
Arm Away + [Access Code] or [Prox Tag] | |
Arm Night + [Access Code] or [Prox Tag] |
PROX TAG SUPPORT:
For “IQ Keypad Prox-PG” models that support Prox Tags, you may Arm with a Prox
Tag in place of a 4 – 6 digit code if Secure Arming is enabled and by pressing
the Arming icon of choice, followed by presenting your tag in front of the
bullseye icon on the lower right hand side of the keypad.
DISARMING
DISARMING KEYS:
Disarming from the IQ Keypad is easy. Simply enter a valid 4 – 6 digit code
into the keypad and the system will disarm.
NOTE: If successful, the Armed Status LED will flash twice. If
communication is not successful, the keypad flashes all keypad number LED’s
(backlight) 0.5 seconds ON/OFF twice. PROX TAG SUPPORT:
For “IQ Keypad Prox-PG” models that support Prox Tags, simply present your tag
in front of the bullseye icon on the lower right hand side of the keypad and
it will light up indicating the the tag has been read successfully. If the
system is armed, presenting a valid Prox Tag will disarm it.
EMERGENCY KEYS:
Emergency keys allow you to trigger an emergency panic directly from the IQ
Keypad.
Key | Description |
---|---|
Press and hold both the 1 & 3 keys simultaneously to generate a fire alarm. | |
Press and hold both the 4 & 6 keys simultaneously to generate an auxiliary |
emergency alarm.
| Press and hold both the 7 & 9 keys simultaneously to generate a police panic
alarm.
NOTE: Press and hold emergency keys for 2 seconds
STAR MENU:
The Star Menu on the IQ Keypad allows access to more advanced functionality
such as silent arming, bypassing zones, turning on/off the chime, buzzer and
more. See table below for a list of functions
Press | Action |
---|---|
[*] + [Arm/Disarm Button] | Silent Arm/Disarm |
[*][1] + [Access Code] | Bypass all open Zones |
[*][4] + [Access Code] | Toggle Chime On/Off |
[*][6] + [Access Code] | Toggle Keypress Buzzer On/Off |
[*][7] + [Output #] + [Access Code] | Toggle Command Output |
[*][8] + [Access Code] | Turn on Installer Programming Access (EN Grade 2 only) |
[*][9] + [Access Code] | Arm System with No Entry Delay |
NOTE: All * menus will follow secure arming option whether an access code
is needed or not
PARTITION ARMING:
The Hash Menu on the IQ Keypad allows access to Partition Arming
functionality. It may also act as a “Home” button to back out of any button
press activity and start over. See table below for a list of functions.
Press | Action |
---|---|
[#][1] + [Arm Stay] + [Access Code] or [Prox] | Arm Partition 1 to Stay |
[#][2] + [Arm Stay] + [Access Code] or [Prox] | Arm Partition 2 to Stay |
[#][3] + [Arm Stay] + [Access Code] or [Prox] | Arm Partition 3 to Stay |
[#][4] + [Arm Stay] + [Access Code] or [Prox] | Arm Partition 4 to Stay |
[#][1] + [Access Code] or [Prox] | Disarm Partition 1 |
Hold [#] for 2 Seconds | Cancels any current IQ Keypad activity or button |
presses
MAINTENANCE
BATTERY REPLACEMENT
- Remove Keypad from Backplate: Unscrew the bottom screw on the bottom of the keypad and then slide up to remove the keypad from the wall mount.
- Remove Batteries: Remove the 4 x AA batteries from the back of the keypad. Do NOT use a screwdriver or anything sharp that could puncture the battery.
- Install New Batteries: Insert new 4 x AA batteries into the battery slots. Be sure to observe polarity.
- Reinstall Keypad on Backplate: Slide the keypad down onto the wall mount and secure with the bottom screw so that it can not be removed. Test and verify functionality with the primary panel.
Use only Energizer AA 1.5V ALKALINE BATTERY
CAUTION: Do NOT use a screwdriver or anything sharp that could puncture
the battery.
LEGAL
UL/cUL RESIDENTIAL FIRE & BURGLARY INSTALLATIONS
This product has been tested and found in compliance with the following
standards: UL1023 Household Burglar-Alarm System Units, UL985 Household Fire
Warning System Units, ULC-S545 Residential Fire Warning Systems Control Units
and ULC-S304 Security Level I Control Units, Accessories and Receiving
Equipment for Intrusion Alarm Systems. For ULC Installations refer to the
Standard for the Installation of Residential Fire Warning Systems,
CAN/ULC-S540.
Wireless Supervision window at the control panel shall be set to 4 hours for
UL/ULC Residential Fire Installations.
Wireless Supervision window at the control panel shall be set to 24 hours for
Residential Burglary Installations only.
UL/ULC COMMERCIAL BURGLARY INSTALLATIONS
This product has been tested and found in compliance with the following
standards: UL2610 Central Station Burglar-Alarm Units and ULC-S304 Control
Units, Accessories and Receiving Equipment for Intrusion Alarm Systems,
Security Levels I-II.
Note: The product is not intended for installation outdoors or outside the
protected premises.
This product is UL/ULC listed under the following categories: AMQE/AMCX7
Central Stations Alarm Units, UTOU/UTOU7 Control Units and Accessories,
Household System Type NBSX/NBSX7 Household Burglar Alarm System Units. For
further information on this product’s listings please also refer to the
official listing guides published at the UL website
(www.ul.com) under Online Directory Section.
Programming:
The notes in the Installation Manual describing the system configurations for
UL/uLC listed installations shall be implemented.
Note: For UL certified Commercial Burglary Central Station applications
the IQ Keypad provides an acknowledgment signal to the user interface to
confirm that normal closing signal has been received once the system has been
armed. The device causes an audible and visual indication, when it receives
the acknowledgment signal transmitted from the monitoring station compatible
receiver: “Panel- Arming Response from Central Station is Acknowledged”
UL/ULC COMMERCIAL BURGLARY INSTALLATIONS continued…
User Information:
– The installer should advise the user and note in the User’s Manual
– Service organization name and telephone number
– The programmed exit and entry time
– Instructions to test system weekly
– Note that the installer code cannot arm or disarm the system
– The installer should caution the user not to give system information (e.g.,
codes, bypass methods, etc.) to casual users (e.g., service people) and to
only give out codes set to expire within 24 hours
– Identification of the conditions that might be expected to result in false
alarms or impaired operation of the product(s): arming the system and not
respecting the exit delay, entering the protected premises and not respecting
the entry delay for disarming the system can cause false alarms.
FCC & ISED CANADA COMPLIANCE STATEMENT
This Class [B] digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe [B] respecte toutes les exigences du
Réglement sur le matériel brouilleur du Canada.
IMPORTANT! Changes or modifications not expressly approved by Qolsys Inc.
could void the user’s authority to operate the equipment.
CAUTION! This equipment complies with radiation exposure limits set forth
for uncontrolled environment. The antenna(s) used for this transmitters must
be installed to provide a separation distance of at least 20 cm from all
persons and must not be collocated or operating in conjunction with any other
antenna or transmitter.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
SPECIFICATIONS
Items | Parameters | 10 Keypad |
---|---|---|
Interface | Type | Capactive touch key mat (0-9, *, #, Arm Stay, Arm Away, Arm |
Night keys)
Wireless| Security R/F| PowerG 912- 919MHz, 868MHz, 433MHz. UL listed models
only operate in 912-919MHz band
LED Indicator| Status LEDs| Trouble. Arming, Status
Buzzer| | lx for key presses. chirps and alarms
Tamper| Tamper Switch| Wall and Enclosure Tamper
Battery| Type| 4 x AA – Use only Energizer AA 1.5V ALKALINE BATTERY
Mechanical| Dimension| 6.1″H x 4.6’W x .91″D (155mm x 117mm x 23mm)
Mount| Back Plate| Wall mount only
Certification| UL/cUL/ULC| UL/cUL Residential Fire and Burglary and UL/ULC
Commercial Burglary Alarm Control Unit. Compliant with standards: UL985,
UL1023, UL2610, ULC-5545, ULC-5304
| FCC/IC| FCC ID: 2AAJXOS-IOKP IC: 11205A-OSIOKP
Temperature| Operational| -10 to 55C, up to 93% relative humidity, indoor, dry
ordinary locations use only ()
| Storage| -40 to 85C, up to 95% relative humidity, indoor, dry ordinary
locations only ()
(*) Note: UL has only verified operation in 0C – 49C and up to 93%RH
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
Document#: IQKPPG-IM-06-23
Revision Date: 06/09/23
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>