**Roth Touchline SL Window Contact Installation Guide

**

Roth Touchline® SL window switch is intended to be installed on the windows inside. When the window is opened, the sensor sends the information to the control unit that it must deactivate heating in the zone after a preset delay.

Roth underfloor heating system

Underfloor Heating System

Registration of Roth Touchline® SL window switch
To register a sensor, select on the control unit which zone the sensor should belong to. Under this zone, select the menu item “Windows sensor”. Select “Registration” when the control unit searches for a sensor, press the learn button on the sensor, (8) within 120 seconds.
When the registration is successful, the control unit displays “Sensor registered” and the window switch Flashes twice. If the LED on the  sensor is permanently lit, there is no communication with the control unit, possibly due to excessive distance.

Installation

Mounting the window switch can be done with the supplied double-sided tape, or with small screws, on the upper part of the window frame (opposite side of the hinges), attach the lower part of the sensor to the tape. Then insert the battery into the lower part, see Fig 2. If you have not subscribed to a channel switch for a channel yet, wait to press the top.
Installation Instruction

  • The magnet must be placed on the window sill, either with double-sided tape!

  • Maximum distance between the sensor and the magnet up to 15 mm and the marking line must be next to each other, see FIg 3.
    Installation Instruction

  • The mounting method is illustrated in the drawing below, Fig 4.
    Installation Instruction

When the window switch is connected to a channel, the upper part can be pressed into place.

If you want to remove all the actuators, do so by pressing “Actuators removal”.
SL Controller

Under “Information” you will nd information about, version, status – open/closed, signal strength and battery status.
SL Controller

Under “Settings” you can set the window switch on/off or set the delay time.
SL Controller
The delay time is the delay from e.g. opens the window until the control unit shuts off the heat in a room.
SL Controller

Roth Touchline® SL QR

ROTH UK Ltd
1a Berkeley Business Park
Wainwright Road
Worcester WR4 9FA
Phone +44 (0) 1905 453424
E-Mail enquiries@roth-uk.com
technical@roth-uk.com
orders@roth-uk.com
accounts@roth-uk.com

roth-uk.com

ROTH DANMARK A/S
Centervej 5
3600 Frederikssund
Tlf. +45 4738 0121
E-mail: service@roth-danmark.dk
roth-danmark.dk

ROTH SVERIGE AB
Höjdrodergatan 22
212 39 Malmö
Tel. +46 40534090
Fax +46 40534099
E-mail: service@roth-sverige.se
roth-sverige.se

ROTH NORGE AS
Billingstadsletta 19
1396 Billingstad
Tel. +47 67 57 54 00
E-mail: service@roth-norge.no
roth-norge.no
facebook.com/RothNorge

ROTH FINLAND OY
Raaseporintie 9 (Talo 2)
10600 Tammisaari
Puh. +358 (0)19 440 330
S-posti: service@roth-finland.fi
roth-finland.fi
facebook.com /RothFinland

Roth logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals