vetus 110120.01 Pump For Grey Water User Manual

May 15, 2024
vetus

vetus 110120.01 Pump For Grey Water

vetus-110120.01-Pump-For-Grey-Water-PRODUCT

Safety

Warning indications
Where applicable, the following warning indications are used in this manual in connection with safety:

DANGER

Indicates that great potential danger exists that can lead to serious injury or death.

WARNING
Indicates that a potential danger that can lead to injury exists.

CAUTION

Indicates that the usage procedures, actions etc. concerned can result in serious damage to or destruction of the engine. Some CAUTION indications also advise that a potential danger exists that can lead to serious injury or death.

NOTE
Emphasises important procedures, circumstances etc.
Symbols

  • Indicates that the relevant procedure must be carried out.
  • Indicates that a particular action is forbidden.

Share these safety instructions with all users. General rules and laws concerning safety and accident prevention must always be observed.

WARNING

This product should only be installed and maintained by qualified personnel who have read and understood the in-structions and precautions in this manual. Failure to follow the instructions in this manual may result in serious injury or property damage. The manufacturer shall not be liable for any damages resulting from improper installation or maintenance by unqualified personnel.

WARNING

This product should only be operated by persons who have read and understood the instructions and precautions in this manual. Failure to follow the instructions in this manual may result in serious injury or property damage. The manufacturer shall not be liable for any damages resulting from improper operation.

Introduction

The VETUS GWDS allows wastewater from the washbasin, shower, dishwasher, air conditioner etc. to be pumped away by one piece of equipment. The equipment is not designed for industrial use.

NOTE

The VETUS GWDS is not suitable for discharging faeces or toilet paper! Make sure that no large objects can get into the pump. This could cause damage! Install a shower drain with filter plate. Make sure that rubber gloves are always available on board.

 Working

When the water level in the container reaches a set level the motor will be started by a signal from the built-in float switch and the water will be pumped out.

Installation

General

  • Position the GWDS behind a wall or under a floor.
  • Make sure that the GWDS always remains accessible by fitting a hatch in the wall or floor.
  • Always tighten all hose connections with good-quality hose clamps!
  • The VETUS GWDS is not fitted with a filter basket. You should therefore always install a strainer in every pipe leading to the GWDS.
  • Attach the 2 supplied fitting lugs (J) with the screws (I) on the bottom of the container.
  • Use the 2 fitting lugs to fit the GWDS.

Preferably position the GWDS amidships and lengthwise in the ship.

The GWDS is guaranteed to work correctly at angles up to 10˚ from fore to aft and 20˚ athwartships.

vetus-110120.01-Pump-For-Grey-Water-FIG-5

Summary of connections

vetus-110120.01-Pump-For-Grey-Water-FIG-7

  1. Shower
  2. Washbasin
  3. Air conditioning
  4. Drain

Connection 1 (shower)
A shower can be connected to the side connection.

vetus-110120.01-Pump-For-Grey-Water-FIG-8

  • Using a sharp knife, remove the closed side of the connection piece (A).
  • Fit the connection piece (A) over the side connection and clamp this with the plastic clamp (B).
  • Fit a reducing piece (not supplied) of ø 40 mm to the correct hose diameter in the connecting piece (A) and clamp this with the plastic clamp (B).
  • Fit the hose.

vetus-110120.01-Pump-For-Grey-Water-FIG-9

Connection 2 (washbasin)

vetus-110120.01-Pump-For-Grey-Water-FIG-10

  • Using a sharp knife, cut open one of the circles indicated. Trim the cut surface well.
  • Remove any sawdust from the GWDS.vetus-110120.01-Pump-For-Grey-Water-FIG-11
  • Place the connection piece (C) in the opening.
  • Place a ø 40 mm reducing coupling (not supplied) to the desired hose diameter in the connection piece (C) and attach it with the help of the hose clamp (D).
  • Fit the hose.

Connection 3 (air conditioning)

vetus-110120.01-Pump-For-Grey-Water-FIG-12

  • Drill an ø 8 mm hole in the hose connection, through trainer.
  • Attach the ø 12 mm hose.

Connection 4 (drain)

  • Attach the kneepiece with a non-return valve (E) using the hose clamp (G).
  • Fit the drain hose (ø 19 mm).
  • Connect the drain hose to a waste water tank. See Installation examples.vetus-110120.01-Pump-For-Grey-Water-FIG-13
  • If the non-return valve (E) is mounted horizontally (to the left or right), ensure that the pivot point of the valve is at the top.vetus-110120.01-Pump-For-Grey-Water-FIG-14

Ventilation
The ventilation is found in the lid.

vetus-110120.01-Pump-For-Grey-Water-FIG-15

  • Attach the cap (H) to the lid.

Electrical connections

  • Check that the voltage given on the type plate on the motor is the same as the voltage on the board.
  • se batteries with sufficient power to guarantee that the GWDS will work correctly.
  • Connect the power supply as shown in the wiring diagram.
  • Fit a switch and a fuse in the (‘+’) wire.
  • Use wires with a minimum cross-section of 6 mm2 (for 12 V) or 4 mm2 (for 24 V).

Taking into service

Once the installation has been completed the equipment which is connected to the GWDS can be taken into use one after the other.

  • Check that all connections are tight.
  • Rinse the sink. The GWDS will start automatically and pump for between 10 and 30 seconds depending on the quantity of water used for flushing. If the pump works for longer than 35 seconds check whether there is a kink in the drain hose or the air vent is blocked.

NOTE

Small leaks, such as a dripping tap in a washbasin, can cause the GWDS to pump unnecessarily!

Use
After installation all equipment which is connected to the GWDS will function in the normal way.

NOTE

Never use the GWDS in combination with an extra powerful hydromassage shower (yield more than 15 litres per minute).

During periods of frost (winter), you should take the following precautions:

  • Switch off the power supply.
  • Drain the pipes.
  • Pour around 1 litre of anti-freeze in the GWDS container, for exam-ple through a connected sink.
  • Anti-freeze is poisonous. Never pour anti-freeze into the open water.

Maintenance

In order to prevent chalk deposits from building up in the pump these should be removed regularly as follows:

  • Switch off the power.
  • Pour around 1 litre of vinegar or descaler in the sink. Add water.
  • Switch the power back on.
  • Rinse the sink.

How often the chalk needs to be removed depends on the hardness of the water.

Dismantling

  • Switch off the power.
  • Drain the drainpipe thoroughly.
  • Disconnect all supply and drain pipes.

If the lid of the GWDS has been opened moisten the rubber seal with liquid soap or detergent before resealing it.

Technical details

vetus-110120.01-Pump-For-Grey-Water-FIG-16

Faults
Make sure that the power is disconnected when carrying out any necessary repairs.

vetus-110120.01-Pump-For-Grey-Water-FIG-17

Installation example

vetus-110120.01-Pump-For-Grey-Water-FIG-18

Wiring Diagram

vetus-110120.01-Pump-For-Grey-Water-FIG-19

  1. Battery
  2. Main switch
  3. Fuse
  4. Switch
  5. Motor

Accessories supplied

vetus-110120.01-Pump-For-Grey-Water-FIG-20

Principal dimensions

vetus-110120.01-Pump-For-Grey-Water-FIG-21

contact

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

vetus User Manuals

Related Manuals