everwell FAHC18HA15 Air Conditioning Instructions
- May 15, 2024
- everwell
Table of Contents
everwell FAHC18HA15 Air Conditioning
Product Information
- Specifications:
- Product: Wall-Mount Air Handlers
- Capacity: 1.5 to 3 Ton
- Models: FAHC18HA15, FAHC24HA15, FAHC30HA15, FAHC36HA15
- Product Features:
- This product offers variation for heating/cooling purposes.
- Installation Instructions:
- Section 1: Safety Precautions
- WARNING: Safety Hazard! Individuals must possess adequate backgrounds of electrical and mechanical experience. Any attempt to repair the product may result in personal injury or property damage.
- WARNING: Hazardous Voltage! Disconnect all electrical power before installing or servicing. Follow proper lockout/tagout procedures to prevent energization.
- WARNING: Live Electrical Components! Follow electrical safety precautions when exposed to live components to avoid serious injury.
- WARNING: Explosion Hazard! Do not store flammable materials near the unit to prevent property damage or injury.
- WARNING: Electrical Hazard! Proper grounding is required to avoid property damage or injury.
- WARNING: Hazardous Vapors! Do not install air handlers with non-ducted return near flammable devices to prevent equipment damage.
- Section 2: Installation Guidelines
- Installation must comply with National, State, and Local Codes. The installation of this unit should be by the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements.
- Section 3: Additional Information
- These instructions may not cover all system variations or contingencies. For further information or specific issues, contact your installing dealer or local distributor.
- Note: Small air handlers are suitable for mobile home use and meet federal OSHA guidelines for safety.
- WARNING: Proposition 65: This appliance contains fiberglass insulation which may cause cancer. Follow safety guidelines.
FAQs
- Q: Can I install the air handler myself?
- A: Installation should be done by individuals with adequate electrical and mechanical experience to avoid injury or damage. Consult a professional if needed.
- Q: Are these air handlers suitable for mobile homes?
- A: Yes, the small air handlers are suitable for mobile home use and meet federal safety guidelines.
All phases of this installation must comply with NATIONAL, STATE AND LOCAL
CODES.
Important: This Document is customer property and is to remain with this
unit.
Product Features
- Front or bottom return air.
- The blower slides out easily for maintenance.
- 2.5, 5, 7.5 and 10 kW single-phase electric heaters.
- Painted finish on galvanized steel.
- Thermoplastic drain pan with bottom primary and secondary drain connections.
- 208/230 VAC operation.
- Stud or wall mounting installation.
- Direct-drive, multi-speed motor allows air volume variation for heating/cooling.
- Factory-installed R410A orifice.
- Built-in filter rack.
- Wall-hanging brackets.
- Fully insulated cabinet.
- 3/4″ NPT primary and secondary drains.
- AHRI certified and ETL listed.
Safety Precaution
Section 1. Safety Precaution
WARNING SAFETY HAZARD!
- This information is intended for use by individuals possessing adequate backgrounds of electrical and mechanical experience.
- Any attempt to repair a central air conditioning product may result in personal injury and/or property damage.
- The manufacturer or seller cannot be responsible forthe interpretation of this information, nor can it assume any liability in connection with its use.
WARNING HAZARDOUS VOLTAGE!
- Disconnect all electrical power, including remote disconnects before installing or servicing.
- Follow proper lockout/tagout procedures to ensure the power can not be inadvertently energized.
- Failure to disconnect power before servicing could result in death or serious injury.
WARNING LIVE ELECTRICAL COMPONENTS!
- During installation, testing, servicing, and troubleshooting of this product, it may be necessary to work with live electrical components.
- Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury.
WARNING EXPLOSION HAZARD!
- Do not store corrosive or combustible materials, gasoline, or other flammable vapours or liquids near the unit.
- Failure to follow this warning could result in property damage, serious personal injury, or death.
WARNING ELECTRICAL HAZARD!
- Grounding Required! Follow proper local and state electrical codes on requirements for grounding. Failure to follow this warning could result in property damage, serious personal injury, or death.
WARNING HAZARDOUS VAPORS!
- Do not install an air handler with a non-ducted return in the same closet, alcove, or utility room as a fossil fuel device.
- Hazardous vapors can be distributed throughout the conditioned space and equipment damage can result.
- Important: These instructions do not cover all variations in systems nor provide for every possible contingency to be met in connection with the installation. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s purposes, the matter should be referred to your installing dealer or local distributor.
- Important: Installation of this unit shall be made by the National Electric Code, NFPA No. 90A and 90B, and any other local codes or utilities requirements.
- Note: The small air handlers have been evaluated by the Code of Federal Regulations, Chapter XX, Part 3280 or the equivalent. “SUITABLE FOR MOBILE HOME USE.”
WARNING
- PROPOSITION 65: This appliance contains fiberglass insulation. Respirable particles of fibreglass are known to the State of California to cause cancer.
- All manufacturer products meet current federal OSHA Guidelines for safety. California Proposition 65 warnings are required for certain products, which are not covered by the OSHA standards.
- California’s Proposition 65 requires warnings for products sold in California that contain or produce any of over 600 listed chemicals known to the State of California to cause cancer or birth defects such as fibreglass insulation, lead in brass, and combustion products from natural vapour.
- All “new equipment” shipped for sale in California will have labels stating that the product contains and/or produces Proposition 65 chemicals. Although we have not changed our processes, having the same label on all our products facilitates manufacturing and shipping. We cannot always know “when, or if” products will be sold in the California market.
- You may receive inquiries from customers about chemicals found in, or produced by, some of our heating and air-conditioning equipment, or found in natural vapour used with some of our products. Listed below are those chemicals and substances commonly associated with similar equipment in our industry and other manufacturers.
- Glass Wool (Fiberglass) Insulation
- Carbon Monoxide (CO)
- Formaldehyde
- Benzene
- More details are available at the websites for OSHA (Occupational Safety and Health Administration), at www.osha.gov and the State of California’s OEHHA (Office of Environmental Health Hazard Assessment), at www.oehha.org.
- Consumer education is important since the chemicals and substances on the list are found in our daily lives. Most consumers are aware that products present safety and health risks, when improperly used, handled and maintained.
CAUTION CORROSION HAZARD!
- To prevent shortening its service life, the air handler should not be used during the finishing phases of construction.
- The low return air temperatures can lead to the formation of condensate.
- Condensate in the presence of chlorides and fluorides from paint, varnish, stains, adhesives, cleaning compounds, and cement creates a corrosive condition that may cause rapid deterioration of the cabinet and internal components.
CAUTION SAFETY HAZARD!
- Sharp Edge Hazard.
- Be careful of sharp edges on equipment or any cuts made on sheet metal while installing or servicing.
- Personal injury may result.
WARNING
- Make sure the blower motor support is tight (3-motor mount bolts) then check to see if the wheel is secured to the motor shaft before operating the unit.
Dimension
Section 2. Dimension Data
Unit Dimensions
Model | Dimensions- In. (mm) | Unit Weight / Shipping Weight Lbs. (kg) |
---|---|---|
Height H | Width W | Width W1 |
18K | 36 (915) | 20-1/2 (522) |
/ 45)
24K| 36 (915)| 20-1/2 (522)| 17-2/5 (442)| 15 (381)| 9-3/5 (244)| 88 / 99 (40
/ 45)
Model | Dimensions- In. (mm) | Unit Weight / Shipping Weight Lbs. (kg) |
---|---|---|
Height H | Width W | Width W1 |
30K | 39-3/5 (1006) | 22 (559) |
- 36K| 39-3/5 (1006)| 22 (559)| 18-4/5 (477)| 19 (485)| 10 (251)| 110/ 121 (50 /
Unit Back Dimensions
Model | Dimensions- In. (mm) |
---|---|
A | B |
18K | 5-3/8 (136) |
24K | 5-3/8 (136) |
30K | 6 (151) |
36K | 6 (151) |
Installation Instructions
Section 3. Installation Instructions
- Unpacking
- Unpack the unit and move to the final location. Remove the carton, taking care not to damage the unit.
- Remove protective sheet metal from the base of the unit, if equipped.
- Inspect equipment for damage before installation. File a claim with the shipping company if the shipment is damaged or incomplete.
- Locate the rating plate on the unit. It contains information needed to properly install the unit. Check the rating plate to be sure the unit matches job specifications.
- A front access panel is provided, which permits access to the blower assembly and electrical controls for removal and servicing.
- Location
- The small air handler should be centrally located and may be installed in a closet, alcove, utility room, or basement. Minimum clearances must be met.
- The air handler comes standard with two different options for mounting, wall mount or frame mount.
- Both mounting options require the unit to be level from side to side and from front to back to allow condensate to properly drain from the unit.
- Failure to do this will result in condensation leaking out from the unit, potentially causing structural damage to the surrounding support structures, drywall, carpet, etc.
- Also, both mounting structures require the ability to accommodate a minimum of 150 lb load.
- Failure to do this will cause damage to the support structure and potentially damage the unit.
- Wall Mount
- The air handler comes standard with a wall mounting bracket and air handler mounting bracket. Reference Figure 3-1 for more details.
- Remove the lower wall mounting bracket from the back of the unit by removing one screw which attaches the bracket to the air handler.
- Note: Discard the screw after you have removed the wall mounting bracket.
- Install bracket on the wall by using 3 wood screws (not provided). Make sure the bracket is level to provide proper drainage from the unit. Note: Do not attach the wall mounting bracket into the unsupported drywall. Make sure that the wood screws are going into a structure that can support a minimum load of 150 lb.
- Lift the air handler above the wall mounting bracket and attach the unit to the installed bracket. Reference Figure 3-1.
- Install the additional bottom plate for extra support for this type of mounting (see Figure 3-1).
- Note: The additional plate is shipped at the bottom of the shipping carton.
- Frame Mount
- The air handler comes with 8 clearance holes (4 on each side).
- These holes are used to mount the air handler inside of a frame structure (see Figure 3-2).
- When mounting in this fashion, make sure that the wood screws are mounted from within the air handler and not from outside the unit to avoid damaging the coil.
- If the frame does not provide support in the front of the unit and additional support is needed, open up the tabs and fix the unit to the frame or other support structure with screws.
- Select a solid and level site to ensure proper installation of the frame mount. Verify that there is sufficient space for installation and maintenance. (see Figure. 3-3)
- IMPORTANT: The (8) wood screws are not provided with the unit. #12 x 1 ½” wood screws are recommended.
- When the unit is installed on a wood frame, the screws should be used to fix the unit to the studs.
- If they are not used, the unit may fall or cause other damage. See Figure 3-2 for frame mount installation.
- Duct Work
- Field ductwork must comply with the National Fire Protection Association NFPA 90A, NFPA 90B and any applicable local ordinance.
- WARNING
- Do not, under any circumstances, connect return ductwork to any other heat-producing device such as a fireplace insert, stove, etc.
- Unauthorized use of such devices may result in fire, carbon monoxide poisoning, explosion, personal injury or property damage.
- Sheet metal ductwork run in unconditioned spaces must be insulated and covered with a vapour barrier. Fibrous ductwork may be used if constructed and installed per SMACNA Construction Standard on Fibrous Glass Ducts. Ductwork must comply with the National Fire Protection Association as tested by U/L Standard 181 for Class | Air Ducts. Check local codes for requirements on ductwork and insulation.
- The duct system must be designed within the range of external static pressure the unit is designed to operate against. The system airflow must be adequate. Make sure supply and return ductwork, grilles, special filters, accessories, etc. are accounted for in total resistance. See airflow performance tables in this manual.
- Design the duct system per “ACCA” Manual “0” Design for Residential Winter and Summer Air Conditioning and Equipment Selection. The latest editions are available from: “ACCA” Air Conditioning Contractors of America. If the duct system incorporates flexible air duct, be sure pressure drop information (straight length plus all turns) shown in the “ACCA” Manual “D” is accounted for in the system.
- Supply plenum is attached to the 3/4″ duct flanges supplied with the unit.
- IMPORTANT: If an elbow is included in the plenum close to the unit, it must not be smaller than the dimensions of the supply duct flange on the unit.
- IMPORTANT: If connected to the blower casing, the front flange on the return duct must not be screwed into the area where the power wiring is located. Drills or sharp screw points can damage the insulation on wires located inside the unit.
- Secure the supply and return ductwork to the unit flanges, using proper fasteners for the type of duct used and tape the duct-to-unit joint as required to prevent air leaks.
- Refrigerant Piping
- Refrigerant pipe connections are located on the top of the unit.
- Refrigerant piping external to the unit shall be sized by the instructions of the outdoor equipment. When units are recessed mounted in the wall, make certain that piping connections are pressure tested before the wall being closed.
- While brazing, be sure to protect the cabinet and grommets from heat damage.
- Metering Device
- All units are shipped and installed with an orifice designed for air conditioning or heat pump operation.
- Pressures equalize after shut shutdown. Some outdoor models may require a start assist kit. See the outdoor unit for more information.
- Blower
- This unit is supplied with a multi-speed motor with a direct drive blower wheel which can obtain various air flows. The unit is shipped with factory-set cooling and heating speed taps. Airflow performance tables are available for additional speed taps.
- Disconnect all power to the unit before making any adjustments to the motor speed taps. Be sure to check the airflow and the temperature drop across the evaporator coil to ensure sufficient airflow.
- Wiring
- Field wiring must comply with the National Electric Code (C.E.C. in Canada) and any applicable local ordinance.
- WARNING
- Disconnect all power to the unit before installing or servicing.
- More than one disconnect switch may be required to de-energise the equipment.
- Hazardous voltage can cause severe personal injury or death.
- Power Wiring
- It is important that proper electrical power is available for connection to the unit model being installed. See the unit nameplate, wiring diagram and electrical data in the installation instructions.
- If required, install a branch circuit disconnect of adequate size, located within sight of, and readily accessible to the unit.
- IMPORTANT: After the Electric Heater is installed, units are equipped with one 60 amp. circuit breaker. These breakers) protect the internal wiring in the event of a short circuit and serve as a disconnect. Circuit breakers installed within the unit do not provide over-current protection of the supply wiring and therefore may be sized larger than the branch circuit protection.
- Supply circuit power wiring must be 75°C minimum copper conductors only. See Electrical Data in this section for ampacity, wire size and circuit protector requirements. Supply circuit protective devices may be either fuses or “HACR” type circuit breakers.
- Power wiring may be connected to either the right or left side. Two 7/8* dia. concentric knockouts are provided for the connection of power wiring to the unit.
- Power wiring is connected to the power cable in the unit’s electric cabinet.
- Control Wiring
- IMPORTANT: Class 2 low voltage control wiring should not be run in conduit with main power wiring and must be separated from power wiring unless class 1 wire of proper voltage rating is used.
- Low voltage control wiring should be 18 AWG. color-coded. For lengths longer than 100 ft., 16 AWG. wire should be used.
- Low-voltage control connections are made to low-voltage pigtails extending from the top of the air handler.
- Connections for control wiring are made with wire nuts. Control wiring knockouts (7/8″) are also provided on the right and left side of the unit for side connection.
- See the wiring diagrams attached to the indoor and outdoor sections to be connected.
- Make sure, after installation, separation of control wiring and power wiring has been maintained.
- Grounding
- WARNING
- The unit must be permanently grounded.
- Failure to do so can result in electrical shock causing personal injury or death.
- Grounding may be accomplished when installed following electrical codes by bonding the metal conduit to the unit cabinet or by attaching ground wire(s) to the ground lug(s) provided in the unit wiring compartment.
- Ground lug(s) are located close to the wire entrance on the left side of the unit (upflow). Lug(s) may be moved to marked locations near the wire entrance on the right side of the unit (upflow) if an alternate location is more convenient.
- The use of multiple supply circuits requires the grounding of each circuit to the lug(s) provided in the unit.
- Electrical Data****
MODEL| VOLTAGE| HERTS| HP| RPM| SPEEDS| CIRCUIT AMPS.| MAXIMUM CIRCUIT PROTECTOR
---|---|---|---|---|---|---|---
18K| 208/230| 60| 1/3| 960| 5| 1.9| 3(A)
24K| 208/230| 60| 1/3| 1010| 5| 2.2| 3(A)
30K| 208/230| 60| 1/2| 960| 5| 2.6| 3(A)
36K| 208/230| 60| 1/2| 1000| 5| 3.2| 6(A) - Air Filter
- An air filter must be installed before air enters the evaporator coil to protect the coil, blower, and other internal parts from excessive dirt and dust.
- A filter must be installed. Consult the filter manufacturer for proper sizing and maximum velocity requirements.
- Filter Sizes***
Model| Filter Sizes in. [mm]
---|---
18K/24K| 1519 [381483]
30K/36K| 2020 [508*508]
- Thermostat
- Select a thermostat that is commonly used with HP or AC single-stage heating/cooling with electric heat. The thermostat will energize the fan on demand for heating or cooling.
- Install the thermostat on an inside wall, away from drafts, lights or other heat sources in a location that has sufficient air circulation from other rooms being controlled by the thermostat. The thermostat should be mounted 4 to 5 feet above the floor.
Sequence of Operation
- Cooling (cooling only)
- Constant torque version – When the thermostat calls for cooling, the circuit from R to G is completed. The blower motor is energized directly by the 24VAC signal from the thermostat.
- The circuit from R to Y is also completed, energizing the compressor contactor of the outdoor unit. The contractor will close and start the compressor and condenser fan motor.
- Cooling (heat pump)
- Constant torque version – When the thermostat calls for cooling, the circuit from R to G is completed. The blower motor is energized directly by the 24VAC signal from the thermostat.
- The circuit from R to Y is also completed, energizing the compressor contactor of the outdoor unit. The contractor will close and start the compressor and condenser fan motor.
- Heating (heat pump)
- Constant torque version – When the thermostat calls for heating, the circuit from R to G is completed and the blower motor is energized directly by the 24VAC signal from the thermostat.
- The circuit from R to Y is also completed, energizing the compressor contactor of the outdoor unit. The contractor will close and start the compressor and condenser fan motor.
- Circuit R to B energizes the reversing valve to the heating position.
- If the indoor temperature continues to fall, the R to W2 circuit is completed, energizing the electric heat contactors).
- Heating (electric heat only)
- Note: The thermostat must be set up to bring the blower on when the electric heat is energized.
- Constant torque version – When the thermostat calls for heating, the circuit from R to G is completed and the blower motor is energized directly by the 24VAC signal from the thermostat. The circuit from R to W1 is completed energizing the heating contactor(s).
- If the indoor temperature continues to fall, the R to W2 circuit is completed, energizing the electric heat contactors).
- Defrost
- Supplemental heat during defrosting can be provided by connecting the W1 (white) wire from the outdoor unit to W1 at the indoor unit. This will prevent cold air from being discharged from the indoor unit during defrosting.
- Low voltage control wiring should be 18 AWG, color-coded (105 degrees C minimum). For lengths longer than 100ft., 16 AWG wire should be used. Make certain that the separation of control wiring and power wiring has been maintained.
Operational And Checkout Procedures
To obtain proper performance, all units must be operated and charge adjustments made by procedures found in the Service Facts document of the outdoor unit. After installation has been completed, it is recommended that the entire system be checked against the following list:
- Be sure unit suspension (if used) is secure and there are no tools or loose debris in, around or on top of the unit.
- Properly insulate suction lines and fittings.
- Properly secure and isolate all refrigerant lines.
- Verify that all electrical connections are tight.
- Check all duct outlets; they must be open and unrestricted.
- Check drain lines and be sure all joints are tight.
- Be sure the return air filter is installed.
- Operate a complete system in each mode to verify proper performance. Verify the operation of a supplementary electric heater.
Maintenance
- The system air filter(s) should be inspected, cleaned or replaced at least monthly.
- Make certain that the access panels are replaced and secured properly before placing the unit back in operation.
- This product is designed for dependable service; however, periodic maintenance should be scheduled and conducted by trained professional service personnel.
- This service should be conducted at least annually and should include testing and inspection of electrical and refrigerant components.
- The heat transfer surface should be cleaned.
- The blower motor is permanently lubricated for normal operating conditions.
Wiring
Section 4. Wiring
Applicable to 18K/24K/30K/36K
Electric Wiring Gauge
Section 5. Electric Wiring Gauge
Note: The cross-section areas of wires or lines should not be less than the corresponding ones listed in the table below; Besides, if the power wires are quite long from the unit, please choose the windings with a larger cross- section area to guarantee the normal power supply.
Model ( cooling only type ) | 18K | 24K | 30K | 36K |
---|---|---|---|---|
Line Gauge | Indoor Unit Power Line | Line Quantity | ||
3 | 3 | 3 | 3 | |
Line Diameter(AWG) | 16 | 16 | 16 | 16 |
Outdoor Unit Power Line | Line Quantity | 3 | 3 | 3 |
Line Diameter(AWG) | 14 | 14 | 12 | 12 |
Indoor- Thermostat Singal Line | Line Quantity | 5 | 5 | 5 |
5
Line Diameter(AWG)| 18| 18| 18| 18
Outdoor- Thermostat Singal Line| Line Quantity| 2| 2|
2| 2
Line Diameter(AWG)| 18| 18| 18| 18
Model ( cooling & heating type **)| 18K| 24K| 30K| 36K
---|---|---|---|---
Line Gauge| Indoor Unit Power Line| Line Quantity|
3| 3| 3| 3
Line Diameter(AWG)| 16| 16| 16| 16
Outdoor Unit Power Line| Line Quantity| 3| 3| 3| 3
Line Diameter(AWG)| 14| 14| 12| 12
Indoor- Thermostat Singal Line| Line Quantity| 5| 5| 5|
5
Line Diameter(AWG)| 18| 18| 18| 18
Outdoor- Thermostat Singal Line| Line Quantity| 5| 5|
5| 5
Line Diameter(AWG)**| 18| 18| 18| 18
Performance Data
Section 6. Performance Data
Airflow performance data is based on cooling performance with a coil and no filter in place. Select the performance table for the appropriate unit size external static applied to the unit allows operation within the minimum and maximum limits shown in the table below for both cooling and electric heat operation.
Airflow Performance (Standard CFM)
Model | Blower Speeds | External Static Pressure(in.w.c) |
---|---|---|
0 | 0.1 | 0.2 |
18K | 1 | 812 |
2-Factory Default | 916 | 875 |
3 | 1005 | 978 |
4 | ||
5 | ||
24K | 1 | 812 |
2 | 916 | 875 |
3-Factory Default | 1005 | 978 |
4 | ||
5 | ||
30K | 1 | 1059 |
2 | 1150 | 1116 |
3-Factory Default | 1282 | 1235 |
4 | 1404 | 1374 |
5 | 1575 | 1534 |
36K | 1 | 1059 |
2 | 1150 | 1116 |
3 | 1282 | 1235 |
4-Factory Default | 1404 | 1374 |
5 | 1575 | 1534 |
NOTES:
- Airflow based upon dry coil at 230V with no electric heat and no filter. For 18, 24, 30 and 36 sizes, airflow at 208V is approximately the same as 230V because the mult-tap ECM motor is a constant torque motor. The torque doesn’t drop off at the speeds at which the motor operates.
- Airflow is equivalent for front or bottom return configurations.
- The air distribution system has the greatest effect on airflow. The duct system is controlled by the contractor. For this reason, the contractor should use only industry-recognized procedures.
- Heat pump systems require a specified airflow. Each ton of cooling requires between 350 and 450 cubic feet of air per minute (CFM), or 400 CFM nominally.
- Duct design and construction should be carefully done. System performance can be lowered dramatically through bad planning or workmanship.
- Air supply diffusers must be selected and located carefully. They must be sized and positioned to deliver air along the perimeter of the space.
- If they are too small for their intended airflow, they become noisy. If they are not located properly, they cause drafts.
- Air grilles must be properly sized to carry air back to the blower. lf they are too small, they also cause noise.
- The installers should balance the air distribution system to ensure proper quiet airflow to all rooms in the home. This ensures a comfortable living space.
MODELS
- FAHC18HA15
- FAHC24HA15
- FAHC30HA15
- FAHC36HA15