everwell DC-810 Relay Overload and Start Capacitor Combo Instructions
- June 17, 2024
- everwell
Table of Contents
DC-810 Relay Overload and
Start Capacitor Combo
Instructions
DC-810 Relay Overload and Start Capacitor Combo
P/N: DC-810
Relay, Overload and Start Capacitor Combo
3 in 1 START from 1/12 to 1/5 HP
Refrigerators / Freezers Domestic & Commercial
Installation Instruction:
- Remove power supply cord.
- Remove old relay and overload.
- Push the pin terminal connected to white wire on RCO onto start terminal of compressor.
- Push pin terminal connected to red wire on RCO onto run terminal of compressor.
- Push pin terminal connected to black wire on RCO onto start terminal of compressor.
- Connect one line wire which was removed from old relay to one of the line wires of the RCO using wire nut.
- Connect other line wire which was removed from the old overload to other live wire of the RCO using wire nut.
277VAC.22A Mex.