RENISHAW TP200 Touch Trigger Probe System User Guide
- May 15, 2024
- RENISHAW
Table of Contents
- RENISHAW TP200 Touch Trigger Probe System
- Product Information
- Product Usage Instructions
- FAQs
- TP200 general information
- Care of equipment
- TP200 product compliance
- EM C conformity
- TP200 safety
- TP200 environmental conditions
- TP200 introduction
- TP200 specification
- Installation procedure
- TP200 probe operation
- Stylus selection
- SCR200 electrical connection
- TP200 maintenance
- TP200 accessories
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- SCR200 stylus change rack kit contents:
RENISHAW TP200 Touch Trigger Probe System
Product Information
Specifications
- Model: TP200
- Documentation Part Number: H-1000-5014-07-B
- Issued: 02 2024
- Company: Renishaw plc
- Registered Office: New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR, UK
Product Usage Instructions
Care of Equipment
Renishaw probes and associated systems are precision tools used for obtaining precise measurements and must therefore be treated with care.
Packaging
To aid end user recycling and disposal, the materials used in the different components of the packaging are stated below:
Packaging Component | Material | 94/62/EC Code | 94/62/EC Number |
---|---|---|---|
Outer Box | Non-corrugated fibreboard | PAP | 21545 |
Box | Polypropylene | PP | 54 |
Packing Foam | Low density polyethylene | LDPE | 54 |
Insert Bag | Polypropylene Low density polyethylene | PP LDPE | 54 |
FAQs
- Q: How do I obtain warranty service for my Renishaw equipment?
- A: To obtain warranty service, refer to the Standard Terms and Conditions provided with the equipment or contact your local Renishaw office for details.
- Q: Where can I find the EU and UK declarations of conformity for the TP200 product?
- A: Contact Renishaw plc or visit www.renishaw.com/EUCMM for the full EU declaration, and www.renishaw.com/UKCMM for the full UK declaration.
“`
TP200 user’s guide
www.renishaw.com
TP200 user’s guide
Documentation part number: H-1000-5014-07-B
Issued 02 2024
1
TP200 user’s guide
www.renishaw.com
TP200 general information
© 1998 – 2024 Renishaw plc. All rights reserved.
ORIGINAL LANGUAGE VERSION
This document may not be copied or reproduced in whole or in part, or
transferred to any other media or language by any means, without the prior
written permission of Renishaw.
Disclaim er
WHILE CONSIDERABLE EFFORT WAS M ADE TO VERIFY THE ACCURACY OF THIS DOCUM ENT
AT PUBLICATION, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS AND LIABILITY,
HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERM ITTED BY LAW. RENISHAW
RESERVES THE RIGHT TO M AKE CHANGES TO THIS DOCUM ENT AND TO THE EQUIPM ENT,
AND/ OR SOFTWARE AND THE SPECIFICATION DESCRIBED HEREIN WITHOUT OBLIGATION TO
PROVIDE NOTICE OF SUCH CHANGES.
Trade marks
RENISHAW®, the probe symbol and REVO® are registered trade marks of Renishaw
plc. Renishaw product names, designations and the mark `apply innovation’ are
trade marks of Renishaw plc or its subsidiaries. Other brand, product or
company names are trade marks of their respective owners.
WEEE
The use of this symbol on Renishaw products and / or accompanying
documentation indicates that the product should not be mixed with general
household waste upon disposal. It is the responsibility of the end user to
dispose of this product at a designated collection point for waste electrical
and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal
of this product will help to save valuable resources and prevent potential
negative effects on the environment. For more information, please contact your
local waste disposal service or Renishaw distributor.
Warrant y
Unless you and Renishaw have agreed and signed a separate written agreement,
the equipment and/ or software are sold subject to the Renishaw Standard Terms
and Conditions supplied with such equipment and/ or software, or available on
request from your local Renishaw office.
Renishaw warrants its equipment and software for a limited period (as set out
in the Standard Terms and Conditions), provided that they are installed and
used exactly as defined in associated Renishaw documentation. You should
consult these Standard Terms and Conditions to find out the full details of
your warranty.
Equipment and/ or software purchased by you from a third-party supplier is
subject to separate terms and conditions supplied with such equipment and/ or
software. You should contact your third-party supplier for details.
Issued 02 2024
2
TP200 user’s guide
Care of equipment
Renishaw probes and associated systems are precision tools used for obtaining
precise measurements and must therefore be treated with care.
Changes to Renishaw products
Renishaw reserves the right to improve, change or modify its hardware or
software without incurring any obligations to make changes to Renishaw
equipment previously sold.
Company registration details
Renishaw plc. Registered in England and Wales. Company no: 1106260. Registered
office: New M ills, Wotton-under-Edge, Gloucestershire, GL12 8JR, UK.
Packaging
To aid end user recycling and disposal the materials used in the different
components of the packaging are stated here:
Packaging component Outer box Box Packing foam Insert Bag
M aterial Non-corrugated fibreboard Polypropylene Low density polyethylene Polypropylene Low density polyethylene
94/ 62/ EC code PAP PP LDPE PP LDPE
94/ 62/ EC number 21 5 4 5 4
CAUTION: If it is necessary to return any part of the system please ensure it is packaged carefully. Failure to do so could result in transit damage for which the customer would be liable. Products supplied in plastic boxes must be returned in the original packaging.
Issued 02 2024
3
TP200 user’s guide
www.renishaw.com
TP200 product compliance
EU declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/ EUCM M for the full EU
declaration.
UK declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/ UKCM M for the full UK
declaration.
AU declaration of conformity
Contact Renishaw plc or visit www.renishaw.com/ AUCM M for the full AU
declaration.
Issued 02 2024
4
TP200 user’s guide
www.renishaw.com
EM C conformity
This equipment must be installed and used in accordance with this installation
guide. This product is intended for industrial use only and should not be used
in a residential area or connected to a low voltage power supply network which
supplies buildings used for residential purposes.
FCC (USA only)
Information to user (47 CFR 15.105)
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case you
will be required to correct the interference at your own expense.
Information to user (47 CFR 15.21)
The user is cautioned that any changes or modifications not expressly approved
by Renishaw plc or authorised representative could void the user’s authority
to operate the equipment.
Equipment label (47 CFR 15.19)
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: 1. This device may not cause harmful
interference. 2. This device must accept any interference received, including
interference that may cause undesired operation.
ICES-001 (Canada only)
This ISM device complies with Canadian ICES-001(A) / NM B-001(A). Cet appareil
ISM est conforme à la norme ICES-001A / NMB-001A du Canada.
Issued 02 2024
5
TP200 user’s guide
www.renishaw.com
REACH regulation
Information required by Article 331 of Regulation EC No. 1907/2006 “REACH”
relating to products containing substances of very high concern (SVHCs) is
available at: www.renishaw.com/ REACH
China RoHS
Contact Renishaw plc or visit www.renishaw.com/ ChinaRoHSCM M for the full
China RoHS tabulation.
Issued 02 2024
6
TP200 user’s guide
www.renishaw.com
TP200 safety
The PI 200-3 interface unit must be connected to a supply incorporating a protective earth conductor via a three-core mains cable (line cord).
PSU electrical ratings Supply voltage range Power frequency range Power consumption Fuse type
85 V – 264 V 47 Hz – 63 Hz 10 W 1 A (T) HBC, 250 V
Your Renishaw probe and accessories are precision instruments. Please use and maintain the products in accordance with these instructions. Please retain the transit box for storing the components when not in use.
CAUTION: The TP200 probe contains sensitive silicon strain sensors.
Permanent damage may be caused if the probe is dropped or subjected to severe shock as may be caused by misuse.
Issued 02 2024
7
TP200 user’s guide
www.renishaw.com
TP200 environmental conditions
The PI 200-3 interface unit is specified to operate under the following conditions which comply with (or exceed) those of standard BS EN 61010-1: 1993/ A2: 1995.
Protection provided by enclosure Altitude Operating temperature Storage
temperature Relative humidity
Transient overvoltage Pollution degree
IP30
Up to 2000 m 0 °C to 50 °C -10 °C to +70 °C Maximum 80% RH up to + 31 °C
Linear decrease to a maximum 50% at + 40 °C Installation category II
2
Issued 02 2024
8
TP200 user’s guide
www.renishaw.com
TP200 introduction
The TP200 / TP200B is a 13.5 mm diameter touch-trigger probe with the facility to quickly change stylus configurations without the need for requalification. Electronic strain sensing techniques are used to improve on the form measuring accuracy and operating life that can be achieved compared with kinematic touch-trigger probes. The TP200 probe is a two piece design comprising the probe body and a detachable stylus module that holds the stylus assembly. The stylus module has a choice of fixed overtravels: ‘SF’ (standard force) or ‘LF’ (low force). There is also the ‘EO’ (extended overtravel) module which has the same overtravel force as the ‘SF’ but provides increased operating range and protection in the probe Z axis. The optional SCR200 stylus change rack provides storage for pre-qualified stylus assemblies and facilitates automatic stylus changing under measurement program control. The probe and rack are powered by the dedicated PI 200-3 interface, which performs signal processing and communicates with the CM M co nt ro ller.
Issued 02 2024
9
TP200 user’s guide
www.renishaw.com
TP200 product description
Probe body
The TP200 probe body houses the strain sensing structure and electronic
processing circuitry. When the stylus contacts the workpiece, in a normal
gauging move, the force applied to the stylus tip is transferred, through the
stylus module and the coupling at the front of the probe body, to the silicon
strain sensors. A tip deflection of a few m is sufficient to trigger the
probe. The probe’s signals are amplified and processed in a hybrid
microcircuit electronic assembly. The probe’s data and control signals are
communicated between the probe and the PI 200-3 interface over a pair of
screened wires, allowing the TP200 system to be compatible with the majority
of Renishaw probe heads and accessories. The TP200B probe body uses the same
technology as the TP200 probe body but has been designed to have a higher
tolerance to vibration. This helps to overcome the problem of ‘air’ trigger
generation which can arise from vibrations transmitted through the CM M or
when using long styli with fast positioning speeds.
NOTE: Renishaw does not recommend the use of TP200B with the LF module or
cranked / star styli.
The stylus module is held in position on the front of the probe body by a
magnetic, kinematic coupling. The coupling allows the stylus module to be
removed and then replaced such that the stylus tip returns to a highly
repeatable spatial position, eliminating the need for req ualif icat io n.
Issued 02 2024
10
TP200 user’s guide
www.renishaw.com
Stylus module
The stylus module carries the M 2 stylus mount and provides overtravel in the
X, Y and + Z probe axes. Overtravel in the -Z probe axis is accommodated by
separation of the module from the probe body. There are three modules
available, with two different overtravel forces: 1. The SF (standard force)
module is suitable for most applications. 2. The LF (low force) module is
recommended for use with small precision ball styli or on delicate materials.
3. The EO (extended overtravel) module is recommended for use when increasing
the speed of the CM M may lead to stopping distances
which exceed the overtravel range provided in the SF / LF modules. The EO
module has an additional 8 mm of overtravel in the probe Z axis to protect
against damage to the probe body in such circumstances. Overtravel force is
the same as the SF module. The module houses the mating half of the
magnetically held kinematic coupling (see ‘Assembling a stylus on a stylus
module’), which ensures repeatable positioning on the probe body. The coupling
consists of three bearing points formed by the V grooves on the rear of the
stylus module, which seat on three ball bearings located on the front of the
probe body. The fourth V groove and semi-recessed ball form an alignment
feature to ensure that the module has a unique orientation in the rotational
axis. The module and stylus axis will be visibly misaligned if the coupling is
not correctly seated. Alignment symbols are provided to assist manual
alignment. The module cover forms a sliding ring (see ‘Probe body’), which
transfers excess force to the case of the probe body if the maximum Z axis
overtravel distance is exceeded.
PI 200-3 interface
The PI 200-3 interface unit powers and services the TP200 / TP200B probe and
up to two SCR200 stylus change racks. The PI 200-3 will service kinematic
switching probes (TP2, TP20, TP6), in addition to the TP200 / TP200B. The PI
200-3 automatically recognises the probe type, determines the status of the
probe and transmits probe trigger signals to the CM M controller. When
automatic stylus changing is performed using the SCR200 change rack, the PI
200-3 inhibits probe triggering and resets the TP200 / TP200B probe to account
for the loading effects of the new stylus assembly on the strain sensors. In
the event of rack overtravel or error condition, the PI 200-3 transmits
signals to the CM M controller to stop CM M motion. During high speed position
moves (fast traverse), it is necessary to reduce probe sensitivity to prevent
vibration causing unwanted triggers. The CM M controller automatically
switches the PI 200-3 into a low sensitivity mode, such that vibration
triggers are prevented. However, a trigger is still issued to stop CMM motion,
if an unexpected collision occurs. This mode is known as `probe damped mode’
and is indicated by an LED on the PI 200-3 front panel.
NOTE: The probe cannot take accurate points when damped mode is selected.
The CM M manufacturer sets the configuration of the PI 200-3 and it should not
be necessary for the user to make adjustments except to operate the reset
button, as explained later in this handbook.
Issued 02 2024
11
TP200 user’s guide
www.renishaw.com
SCR200 stylus change rack
The SCR200 holds and protects up to six stylus modules for automatic changing.
The modules are magnetically held in the docking ports, which allows the rack
to be mounted in any orientation and eliminates the need for high accuracy
positioning. No special commands are necessary, as stylus changing requires
only simple position moves to be programmed. The SCR200 incorporates a system
of infrared light beams and a Hall effect sensor to detect the presence of the
probe and to signal to the PI 200-3 interface that stylus changing is in
progress. A self-test mode checks operation of the light beams during power-
up. The rack is provided with an overtravel mechanism to reduce the
possibility of damage should a collision occur. When the mechanism is
deflected, signals are transmitted to the CM M controller to stop CM M motion.
The overtravel mechanism is self-resetting. After a collision, the rack should
return to its normal operating position and should not require re-datuming.
Issued 02 2024
12
TP200 user’s guide
www.renishaw.com
TP200 specification
M easuring performance
The following data is derived from test rig measurements and may not represent
the performance achievable on a CM M . Please contact your CM M supplier for
overall system accuracy information.
NOTES: Tested with standard Renishaw M 2 steel and GF styli gauging speed 8
mm/ s. Repeatability and XY (2D) form measurements as specified to Renishaw
in-house test standards. 3D form measurements as specified to standard ASM E
B89.4.1-1997 for point-to-point probing.
Unidirectional repeatability 2 m
Stylus type St raig ht St raig ht St raig ht St raig ht St ar St ar
Offset length A (mm) 10 50 70 100 5 50
Offset length B (mm) 20 20
Trigger level 1 µm 0.2 0.4 0.7 1 0.5 0.7
Trigger level 2 µm 0.25 0.5 1 1.2 0.7 1
Issued 02 2024
13
TP200 user’s guide
www.renishaw.com
XY (2D) form measurement deviation
Stylus type St raig ht St raig ht St raig ht St raig ht St ar St ar
Offset length A (mm) 10 50 70 100 5 50
Offset length B (mm) 20 20
Trigger level 1 µm ±0.4 ±0.8 ±0.9 ±1.7 ±1 ±1
Trigger level 2 µm ±0.5 ±0.9 ±1.5 ±2 ±1.2 ±1.2
XYZ (3D) form measurement deviation
Stylus type St raig ht St raig ht St raig ht St raig ht St ar St ar
Offset length A (mm) 10 50 70 100 5 10
Offset length B (mm) 20 20
Trigger level 1 µm ±0.65 ±1 ±2 ±4 ±1.5 ±3
Trigger level 2 µm ±0.9 ±1.4 ±3 ±5.5 ±2.2 ±4
Repeatability of stylus change
Automatic change with SCR200 1 m max.
M anual change 2 m typical
Overtravel forces
Standard force module
Stylus length 20 mm at typical overtravel 50 mm at typical overtravel 50 mm at
max. overtravel
XY axis low force (g) 45 20 25
XY axis high force (g) 70 40 50
Z+ axis (g) 490 490 1500
Issued 02 2024
14
TP200 user’s guide
www.renishaw.com
Low force module
Stylus length 20 mm at typical overtravel 50 mm at typical overtravel 50 mm at
max. overtravel
Overtravel limits
XY axis ±14°
Technical data
Trigger forces Gauging speed range Trigger rate Sense directions M odule life
M odule pull-off force Probe cable length Probe cable resistance Operating
temperature range Storage temperature range Probe length Probe diameter Probe
connector Stylus mount Sealing W eight
XY axis low force (g) 20 10 15
XY axis high force (g) 30 15 25
Z+ axis
4.5 mm (SF / LF) 12.5 mm (EO)
0.02 N (2 gF) (at 50 mm stylus tip) 0.5 mm/ s – 80 mm/ s 5 triggers/ s max 6 way: ±X, ±Y, ±Z > 10 million triggers 800 g to 1000 g Max 50 m × 0.22 mm² Max 5 / conductor +10 °C to +40 °C -10 °C to +70 °C 43 mm 13.5 mm M8 × 1.25 × 5 mm M2 × 0.4 mm IP30 15 g (sensor) 7 g (module)
Z+ axis (g) 160 160 450
Z- axis 4 mm
Issued 02 2024
15
TP200 user’s guide
www.renishaw.com
Dim en sio n s
TP200 probe system
Issued 02 2024
16
TP200 user’s guide
www.renishaw.com
SCR200
Issued 02 2024
17
TP200 user’s guide
www.renishaw.com
Installation procedure
M ounting the probe body on the probe head
CAUTION: Take great care not to drop the probe when installing.
Mount the probe body on the probe head before fitting a stylus module.
Probe heads with M 8 connector
Screw the threaded end of the probe body into the M8 connector, on the probe
head, until it is finger-tight Fit the S1 `C’ spanner supplied to the location
holes and tighten by hand The recommended tightening torque is 0.3 Nm – 0.5 Nm
Issued 02 2024
18
TP200 user’s guide
www.renishaw.com
Probe heads with Renishaw autojoint
Before fitting to the probe head, screw the probe body to a PAA series
adaptor, as instructed above for M 8 heads Locate the adaptor on the probe
head and lock the autojoint using an S10 key
Issued 02 2024
19
TP200 user’s guide
www.renishaw.com
Assembling a stylus on a stylus module
For a one-piece stylus, screw the stylus into the threaded mount on the stylus
module until finger-tight. Fit an S7 pin spanner (supplied) into the stylus
cross-hole and tighten using finger pressure to achieve the recommended torque
of between 0.05 Nm and 0.15 Nm.
NOTE: The maximum permissible torque is 0.3 Nm.
Where an offset or star stylus arrangement is to be used, assemble the
arrangement loosely and offer the module up to the probe body to check
alignment. Adjust the alignment with the module removed and tighten as
described above using one or two S7 pin spanners as necessary. Styli from the
Renishaw GF (carbon fibre reinforced plastic) range must be tightened using
the S20 tightening tool (supplied with the stylus kit). When tightening GF
styli or extension pieces do not apply torque to the stylus stem. It may be
necessary to use two S20 tools or S20 and S7 tools in combination to tighten
adjacent threaded couplings. Refer to the instruction leaflet (Renishaw part
number H-1000-4003) provided with the stylus kit.
Issued 02 2024
20
TP200 user’s guide
www.renishaw.com
M ounting the stylus module on the probe body
Visually examine the mating faces of the stylus module and the probe body for
dirt or other contamination. Clean if necessary using the CK200 cleaning
material (supplied), (refer to the ‘M aintenance’ section). Offer up the
stylus module to the probe body ensuring that the alignment symbols are
matched. Allow the stylus module to engage under the pull of the magnetic
force. Reset the probe as described in the following section ‘Resetting the
probe’.
Resetting the probe
Press the RESET button, on the front panel of the PI 200-3 interface, for two
seconds to reset the probe to the seated (armed) state.
CAUTION: Probe triggers are inhibited when the RESET button is pressed. Before
pressing the button, the CM M must be stationary with the probe stylus clear
of the workpiece.
NOTE: When the TP200 is mounted on a motorised head, the action of unlocking
and locking the head will perform the same function as the RESET button.
Issued 02 2024
21
TP200 user’s guide
www.renishaw.com
TP200 probe operation
The TP200 probe has two normal operating states – armed or triggered. The
probe should be in the armed state except for the moments when the stylus is
deflected against the workpiece.
Probe armed
When the probe is armed sometimes called seated’ or
reset’ the following PI
200-3 front panel indicators will be ON: POWER ON TYPE – TP200 PROBE – SEATED
Additionally, the probe head LED will be ON and the LEDs on the TP200 probe
body will be OFF. The probe LEDs may sometimes glow slightly, indicating a low
level of background vibration.
Probe triggered
When the stylus touches the workpiece the LEDs on the probe body turn ON
brightly. The SEATED and probe head LEDs will turn OFF. The probe should be
allowed to remain in the triggered state only for the minimum time necessary
to reverse the CM M motion and back-off from the workpiece. If the probe
remains in the triggered state for more than 10 seconds, drift of the stylus
zero reference position will occur and the PI 200-3 will emit an audible
warning. Back-off the probe from the workpiece and refer to ‘Resetting the
probe’.
Changing a stylus module manually
Ensure the CM M will remain stationary, in a safe condition. Remove the stylus
module and store safely. To fit another module, refer to the ‘M ounting the
stylus module to the probe body’ section. When using M H8 or M IH probe heads,
unlock and relock the head before resetting the probe. Reset the probe, refer
to the ‘Resetting the probe’ section.
Operation with a manual probe head
After manually re-orientating the probe when using PH1, M H8 or M IH probe
heads, reset the probe. Refer to the ‘Resetting the probe’ section.
Issued 02 2024
22
TP200 user’s guide
www.renishaw.com
Stylus module selection
The SF module is satisfactory for the majority of applications and provides
the maximum stylus carrying capability. The LF module should be employed where
the application necessitates the use of styli with ball diameters less than 1
mm, particularly the PS29R (Renishaw part number A-5000-7800), or where lower
overtravel force will reduce the risk of marking or deflecting the surface of
the workpiece. The EO module is recommended for use when increasing the speed
of the CM M may lead to stopping distances which exceed the overtravel range
provided in the SF / LF modules.
NOTE: The overtravel force, in the X-Y axis, varies with both direction and
displacement for a given stylus length. In the X-Y axis there is a pattern of
three maximum and minimum force directions as illustrated in figure below:
Issued 02 2024
23
TP200 user’s guide
www.renishaw.com
Stylus selection
To obtain the best performance apply the following considerations when selecting and fitting a stylus: Use the shortest possible stylus length M inimise the mass of the stylus by using the types with ceramic or GF stems where possible – refer to the Renishaw stylus catalogue for further information Work within the recommended stylus limits Ensure that stylus balls, threads and mating faces are kept clean Tighten styli using only the tools provided Use the stylus changing facility to optimise the styli for accuracy and feature access Always qualify the styli at the gauging speed set for the part measurement program. If the speed is changed re-qualify the stylus tips
Issued 02 2024
24
TP200 user’s guide
www.renishaw.com
Recommended stylus limits
The absolute maximum stylus carrying ability of the TP200 probe is determined
by the mass of the stylus and the distance from the stylus holder to the
centre of gravity. The limits are:
Low force module 3 g at 20 mm
Standard force module 8 g at 50 mm
In practice, the stylus carrying is restricted by CM M vibration level, probe
orientation and CM M controller flexibility. The recommended limits are given
in the figures below.
It may be possible to exceed the recommended limits but the user is advised to
conduct trials to establish the suitability for the application and the effect
on measuring performance.
Recommended stylus limits – LF module:
Issued 02 2024
25
TP200 user’s guide
www.renishaw.com
Recommended stylus limits – SF / EO modules:
Issued 02 2024
26
TP200 user’s guide
www.renishaw.com
Trigger level
Under certain conditions, vibration may cause false `air’ triggers during
gauging and it may be necessary to reduce the probe sensitivity. False
triggers may occur when large or heavy stylus arrangements are used, or where
there is floor transmission from nearby machinery or vehicles.
Trigger level 1 – the highest sensitivity mode, provides the best measuring
accuracy Trigger level 2 – lower sensitivity to vibration but with a small
loss of measuring accuracy The trigger level is selected by switch 10 on the
rear panel of the PI 200-3 interface: Level 1 – switch 10 DOWN Level 2 –
switch 10 UP
NOTE: For versions of the PI 200-3 prior to V9, the trigger level was adjusted
by switch 11.
The trigger level selection does not affect sensitivity when the probe is in
damped mode. Please consult your CM M supplier before making any adjustment to
the PI 200-3 settings. All stylus tips must be re-qualified after changing the
trigger level.
Issued 02 2024
27
TP200 user’s guide
www.renishaw.com
Installation procedure – SCR200 rack
M ounting the SCR200 rack on the CM M
Place the location piece over a threaded insert at the desired location on the
CM M table and screw down using a M 8 or M 10 bolt and hexagon key (supplied).
A special location piece with integral bolt is available for M 12 inserts
(Renishaw part number M -1371-0298). If using this tighten using an S1 `C’
spanner supplied with the probe kit. Locate the base of the SCR200 rack over
the location piece and partially tighten the fixing screw using the 1.5 mm AF
hexagon key (supplied). Before fully tightening the fixing screw, rotate the
rack and align with the CM M axes as described in the following procedure.
NOTES: Your CM M supplier’s instructions will indicate the preferred method of
alignment. Alignment of the SCR200 with the CM M axes may be essential for
some measurement programs or may be desirable for ease of programming.
Issued 02 2024
28
TP200 user’s guide
www.renishaw.com
Aligning the SCR200 rack to the CM M axes
Align the rack approximately by eye. Take points P1 and P2 see `Datuming the
SCR200 rack’. Carefully rotate the rack until the runout between points P1 and
P2 is less than 0.2 mm. Tighten the fixing screw using the 1.5 mm AF hexagon
key (supplied).
Datuming the SCR200 rack
Renishaw recommends that the PS2R stylus (supplied) is used to datum the
SCR200 rack.
NOTE: For racks previously supplied with a PS35R stylus, the instructions are
identical.
If a different stylus is used, the length (L) (minimum 20 mm) and the ball
radius (R) must be used to calculate offsets. The following instructions
assume uncompensated probing points are taken. Therefore, the target positions
for stylus module changing are given in absolute machine coordinates. The X,
Y, Z axis system refers to the rack axes indicated in the following figure:
Issued 02 2024
29
TP200 user’s guide
www.renishaw.com
IM PORTANT: The SCR200 rack must NOT be connected to the PI 200-3 interface
when performing the datuming procedure.
Remove the electrical connector before datuming the rack Open the lids of
ports 1 and 6 and latch in position by sliding towards the centre of the rack
Establishing the docking depth (Y)
Take point P3 The docking depth for all ports is: {Y = P3 + R (1 mm) + 14.0
mm}
Establishing the docking height (Z)
Take point P4 on the top face, ensuring that the point is not taken on the
label The docking height for all ports is: {Z = P4 L 20 mm R 1 mm 18.6
mm}
Issued 02 2024
30
TP200 user’s guide
www.renishaw.com
Establishing the X-axis docking centres for ports 1, 2 and 3 (X1, X2, X3)
Take points P5 and P6 using the stylus shank to gauge the edges of the module
retention plate in port 1 The docking centre for port 1: {X1 = centre point
P5/ P6} The docking centre for port 2: {X2 = X1 + 30 mm} The docking centre
for port 3: {X3 = X1 + 60 mm}
Establishing the X-axis docking centres for ports 4, 5 and 6 (X4, X5, X6)
Take points P7 and P8 using the stylus shank to gauge the edges of the module
retention plate in port 6 The docking centre for port 6 is: {centre point P7/
P8 = X6} The docking centre for port 4: {X4 = X6 – 60 mm} The docking centre
for port 5: {X5 = X6 – 30 mm}
Summary of docking target coordinates
Port 1 = X1, Y, Z Port 2 = X2, Y, Z Port 3 = X3, Y, Z Port 4 = X4, Y, Z Port 5
= X5, Y, Z Port 6 = X6, Y, Z
CAUTION: The constant Y value assumes the SCR200 is aligned to your CM M axes
or is using its own coordinate system.
After datuming the rack
Close the lids of ports 1 and 6 Select the operating mode (Tamper proof ON or
OFF, refer to the ‘Operating modes’ section) Connect the cable to the PI 200-3
interface and observe the POWER and STATUS LEDs for correct indication Refer
to the ‘Loading stylus modules into the rack’ section
Issued 02 2024
31
TP200 user’s guide
www.renishaw.com
SCR200 electrical connection
Suitable cables for connection of the SCR200 rack to the PI 200-3 interface are available from Renishaw in three standard lengths:
Cable name
PL63 PL64 PL65
Part number A- 1016- 7630 A- 1016- 7631 A- 1016- 7632
Lengt h
5 m (196.85 in) 10 m (393.7 in) 15 m (590.55 in)
For applications requiring a second rack, a dual rack splitter cable is available.
Cable name
PL97
Part number A- 1016- 7660
Lengt h 260 mm (10.24 in)
NOTE: 2 × standard rack cables of the correct length will be required in addition to the dual SCR200 adaptor cable, which must be installed at the PI 200-3 end.
Issued 02 2024
32
TP200 user’s guide
www.renishaw.com
SCR200 rack operation
Operating modes
The SCR200 may be operated in either of two modes depending on the application
requirements and whether the SCR200 is accessible in normal operation. With
TAM PER PROOF ON selected, the stylus change cycle is initiated by moving the
probe across the face of the Hall sensor, for the rack to detect the presence
of the probe before entering a docking port. In this mode, interruption of the
light beams alone does not inhibit probe triggering and therefore the probe
cannot be accidentally inhibited during normal operation. For example by
placing fingers in the light beam or by operating a port lid. With TAM PER
PROOF OFF selected, direct entry to the rack ports is allowed. The light beams
detect the probe entering a module docking port and inhibit probe triggers. In
this mode faster stylus changing is possible but Renishaw recommend that it is
used only in situations where access to the rack is restricted when the CM M
is operating automatically.
To select the operating mode
Remove the electrical connector M ove the mode selection slide switch (see ‘M
ounting the SCR200 rack on the CM M ‘) – LEFT for tamper proof ON, RIGHT for
tamper proof OFF Replace the electrical connector Confirm that the POWER and
STATUS lamps are indicating the correct mode
Loading stylus modules into the rack
Renishaw recommends that the stylus modules are mounted on the probe body by
hand. An automatic stylus change routine is completed prior to tip
qualification then the stylus module is loaded into the rack. The CM M should
be used to load the stylus modules into the rack by following the ‘Stylus
module changing procedure’. It is possible to load the rack by hand but care
must be taken to ensure correct rotational alignment, as there is no warning
if a module is incorrectly seated on the probe sensor and gross measurement
errors will occur.
Issued 02 2024
33
TP200 user’s guide
www.renishaw.com
Power and status indicators
Two LEDs are located on the top face of the rack: 1. POWER – green 2. STATUS –
red
Power OFF OFF ON ON ON
Flashing
St at us Flashing for 10 s Flashing for 5 s
OFF ON Flashing Flashing
SCR200 mode Self-test, tamper proof ON Self-test, tamper proof OFF Rack idle,
tamper proof ON Rack idle, tamper proof OFF
Stylus changing Self-test failed
Stylus module changing procedure
Storing a stylus module – tamper proof ON
Refer to the ‘Datuming the SCR200 rack’ section for definitions of coordinate
X(n), Y, Z. 1. M ove to the START coordinate for activating the Hall sensor:
{Xs, Ys, Z}, where Xs = X1 + 82 mm and Ys = P3 + R (1 mm) – 7.5 mm. 2. M ove
along the X- axis to: {Xs – 12 mm} at a minimum speed of 5 mm/ s. 3. M ove
along the X axis to the centre line of the required vacant port (n): {X(n),
Ys, Z}.
NOTE: If the stylus assembly has an offset or star component projecting along
the Y+ axis, it is permissible (after step 1) to move out along the Y- axis
and exit the light beam for a maximum of 5 s, to avoid a collision with the
SCR200 leg or another stored st ylu s.
4. M ove along the Y+ axis to the docking target coordinate for port (n):
{X(n), Y, Z} 5. M ove along the Z+ axis to the release coordinate: {X(n), Y,
Zr} where Zr = Z + 3 mm. 6. M ove along the Y- axis to a coordinate clear of
the port lid: {X(n), Ys, Zr}
Issued 02 2024
34
TP200 user’s guide
www.renishaw.com
Storing a stylus module – tamper proof OFF
Refer to the previous procedure (‘Storing a stylus module – tamper proof ON’)
omitting steps 1 and 2. NOTE: It is not necessary to stop CM M motion at the
start coordinate in this mode, provided that the port is entered along the Y+
axis at the specified X(n) and Z axis positions.
Issued 02 2024
35
TP200 user’s guide
www.renishaw.com
Picking up a stylus module
This procedure is applicable to both operating modes. Refer to the section
‘Datuming the SCR200 rack’ for definitions of coordinate X(n), Y, Z. 1. From
the previous port coordinate: {X(n), Ys, Zr}, move along the X axis to the
port (n) containing the required stylus module: {X(n), Ys, Zr} 2. M ove along
the Y+ axis to the port centre: {X(n), Y, Zr} 3. M ove along the Z- axis to
the docking target coordinate for port (n): {X(n), Y, Z} 4. M ove along the Y-
axis to a coordinate clear of the port lid: {X(n), Ys, Z} Proceed with the
part measurement program.
Issued 02 2024
36
TP200 user’s guide
www.renishaw.com
TP200 maintenance
TP200 probe body and stylus module
The kinematic coupling mechanism, connecting the probe body to the stylus
module, incorporates precision ball / V groove seatings. The coupling
mechanism has been tested in a wide range of environments and is highly
tolerant of non-metallic dust, but regular inspection and cleaning with the
CK200 material (supplied) is recommended to ensure continued high performance.
Instructions for use are included with the cleaning material (Renishaw part
number A-1085-0016). The user should determine the frequency of cleaning
according to the conditions of use. Stylus balls, threads and mating faces
should be cleaned with a proprietary cleaning cloth or solvent. Stylus modules
that are not in use should be stored in spare ports in the SCR200 rack or in
their transport boxes.
SCR200 rack
Periodic cleaning of the rack ports, lids and outer surfaces using a
proprietary cleaning cloth, is recommended to prevent contamination of the
modules.
Issued 02 2024
37
TP200 user’s guide
www.renishaw.com
TP200 fault finding
The CM M will not register a probe trigger, but the probe operates normally when the stylus is deflected by hand:
PI 200-3 indicators
‘STOP’ lamp ON ‘TP200’ lamp ON ‘SEATED’ LED operates normally
Possible causes
The CM M controller or a Renishaw system has activated STOP signal. SCR200
overtravel mechanism is deflected.
Remedy
Check status of Renishaw motorised probe head or other systems. Clear
obstruction and allow overtravel mechanism to reset.
The probe fails to trigger and the probe LEDs glow only dimly when the stylus touches the workpiece, but the probe operates normally when the stylus is deflected by hand:
PI 200-3 indicators ‘SEATED’ LED ON
Possible causes
The trigger speed is too slow. The stylus is too heavy.
Remedy
Probe normally to the workpiece surface. Increase gauging speed.
The probe will not arm or the probe does not stay armed when the RESET button is released. The probe LEDs are always OFF:
PI 200-3 indicators
‘STD’ LED ON ‘SEATED’ LED OFF
Possible causes
Probe sensor faulty. Probe wiring open circuit.
Remedy
Remove probe and test by substitution. Check wiring from probe to PI 200-3
interface.
The probe will not arm or the probe does not stay armed when the RESET button is released. The probe LEDs are always ON:
PI 200-3 indicators
‘TP200’ LED ON ‘SEATED’ LED OFF
Possible causes
Remedy
Probe sensor faulty or damaged by collision. Remove probe and test by substitution.
Issued 02 2024
38
TP200 user’s guide
www.renishaw.com
False `air’ triggers occur while the CMM is stationary and the probe LEDs flicker:
PI 200-3 indicators
‘TP200’ LED ON ‘SEATED’ LED operates normally
Possible causes
Probe sensor faulty Probe loose in probe head Excessive vibration from
external source Excessive vibration from CM M
Remedy
Remove probe and test by substitution Correctly tighten probe Remove cause or
isolate CM M Check CM M air supply M aintain CM M air bearing system
False `air’ triggers occur at gauging speed and the probe LEDs flicker:
PI 200-3 indicators
‘DAM PED’ LED is OFF ‘SEATED’ LED operates normally
Possible causes
Stylus is too large or heavy Excessive vibration from CM M
Remedy
Use stylus arrangements within recommendations. Check CM M air supply M
aintain CM M air bearing system
False `air’ triggers occur at traverse speed and the probe LEDs flicker:
PI 200-3 indicators
‘DAM PED’ LED is ON ‘SEATED’ LED operates normally
Possible causes
Stylus is too large or heavy Excessive vibration from CM M Traverse speed is
too high
Remedy
Use stylus arrangements within reco m m end at io ns Check CM M air supply M
aintain CM M air bearing system Reduce traverse speed
The probe triggers during an SCR200 stylus change:
PI 200-3 indicators ‘SEATED’ LED operates normally
Possible causes
Remedy
The SCR200 is not connected to the PI 200-3 Check SCR200 indicator lamps
Incorrect SCR200 operating mode
Re-connect cable
Issued 02 2024
39
TP200 user’s guide
www.renishaw.com
There is an unexpected loss of accuracy: PI 200-3 indicators ‘TP200’ LED ON
‘SEATED’ LED operates normally
Deflection alarm active: PI 200-3 indicators Audible indicator ON
Possible causes
Stylus ball is damaged or dirty. Stylus is too large or heavy. The probe is
loose or not correctly assembled. The kinematic coupling is damaged or dirty.
The gauging speed has been changed. The trigger threshold has been changed.
Remedy
Inspect and clean stylus ball, or replace and re-qualify the stylus. Use
stylus arrangements within recommendations. Check the stylus joints. Ensure
the module is correctly seated and the probe is tight in the probe head.
Inspect and clean the kinematic coupling. Re-qualify stylus tips.
Possible causes
The stylus is or was deflected for > 10 s. Stylus module was changed manually.
Remedy
M ove the stylus clear of any obstruction and press the RESET button
Issued 02 2024
40
TP200 user’s guide
www.renishaw.com
TP200 accessories
High performance styli
For applications requiring styli longer than 40 mm, the Renishaw range of
lightweight GF’ styli and extension pieces are recommended. These are available individually or as a boxed kit (Renishaw part number A-5003-2310). See the stylus catalogue (Renishaw part number H1000-3200) for further information. Extension bars and adaptors Probe reach may be extended, with minimal loss of accuracy using probe extension bars. These are available in M 8 – M 8 or autojoint – M 8 connector versions according to the type of probe head in use. See the
Probing systems
for coordinate measuring machines’ catalogue Renishaw part number H-1000-5050
for details.
Issued 02 2024
41
TP200 user’s guide
www.renishaw.com
Part number summary
Probes
D escript ion TP200 probe body TP200B probe body
Part number A- 1207- 0020 A- 1207- 0056
Probe kits
D escript ion TP200 probe kit 1 (including standard force module) TP200 probe
kit 2 (including low force module) TP200B probe kit 1 (including standard
force module) TP200B probe body only
Part number A- 1207- 0001 A- 1207- 0002 A- 1207- 0055* A- 1207- 0056
TP200 stylus modules
D escript ion TP200 standard force stylus module TP200 low force stylus module
TP200 extended overtravel stylus module
Part number A- 1207- 0010 A- 1207- 0011 A- 1207- 0012
PI 200-3 probe interface
D escript ion PI 200-3 probe interface for TP1, TP2, TP6, TP20 and TP200
Part number A- 5707- 0100
SCR200 stylus changing rack
D escript ion
Part number
SCR200 kit- active six port change rack for use with TP200 (including A-1207-0030# 3 × standard force stylus modules
SCR200 kit – active six port change rack for use with TP200 including 3 × low force stylus modules
A- 1207- 0070#
SCR200 only
A- 1207- 0260
Issued 02 2024
42
TP200 user’s guide
www.renishaw.com
TP200 accessories
D escript ion M 12 location piece (re: SCR200) PL63 (5 m) SCR200 to PI 200-3 cable PL64 (10 m) SCR200 to PI 200-3 cable PL65 (20 m) SCR200 to PI 200-3 cable PL97 0.26 m dual adaptor cable for connecting 2 × SCR200 racks to PI 200-3 requires 2 × cables PL63 / PL64 / PL65 in addition
Part number M -1371-0298 A- 1016- 7630 A- 1016- 7631 A- 1016- 7632 A- 1016- 7660
Rep lacem ent s
D escript ion CK200 cleaning material S1 ‘C’ spanner S9 double ended ‘C’ spanner S7 stylus tool Hexagon key 1.5 mm AF
- TP200 / TP200B probe kit contents:
TP200 probe body Stylus module Tools / cleaning kit Test certificate User’s guideSCR200 stylus change rack kit contents:
SCR200 rack Stylus modules ×3 Mounting kit Datuming stylus
Part number A- 1085- 0016 A- 1042- 1486 A- 1047- 3932 M -5000-3540 P- TL03- 0150
Issued 02 2024
43
Renishaw plc New Mills, Wotton-under-Edge Gloucestershire, GL12 8JR United Kingdom
T +44 (0)1453 524524 F +44 (0)1453 524901
www.renishaw.com/cmmsupport
For worldwide contact details, please visit our main website at
www.renishaw.com/contact
Issued 02 2024
References
- declaration.au
- Domain parking page
- AU declarations of conformity
- China RoHS - CMM products
- EU declarations of conformity - CMM products
- UKCA declarations of conformity - CMM products
- Renishaw: enhancing efficiency in manufacturing and healthcare
- Contact us
- AU declarations of conformity
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>