Intended use
The NC4+ Blue is a laser-based non-contact tool setting system that provides a
high-speed, high-precision measurement of cutting tools on a machining center
under normal operating conditions.
Safety
Information to the user
In all applications involving the use of machine tools or CMMs, eye protection
is recommended.
Information for the machine supplier/installer
It is the machine supplier’s responsibility to ensure that the user is made
aware of any hazards involved during operation, including those mentioned in
Renishaw product literature, and to ensure that adequate guards and safety
interlocks are provided.
Under certain circumstances, the probe signal may falsely indicate beam is not
blocked. Do not rely on probe signals to halt the movement of the machine.
Information to the equipment installer
All Renishaw equipment is designed to comply with the relevant EU and FCC
regulatory requirements. It is the responsibility of the equipment installer
to ensure that the following guidelines are adhered to, in order for the
product to function in accordance with these regulations:
- any interface MUST be installed in a position away from any potential sources of electrical noise (for example, power transformers, servo drives);
- all 0 V/ground connections should be connected to the machine “star point” (the “star point” is a single point return for all equipment ground and screen cables). This is very important and failure to adhere to this can cause a potential difference between grounds;
- all screens must be connected as outlined in the user instructions;
- cables must not be routed alongside high current sources (for example, motor power supply cables), or be near high-speed data lines;
- cable lengths should always be kept to a minimum.
Equipment operation
If this equipment is used in a manner not specified by the manufacturer, the
protection provided by the equipment may be impaired.
Warnings
Use of controls or adjustments or performance of procedures other than those
specified within this publication may result in hazardous radiation exposure.
Switch off the power supply before carrying out maintenance on the NC4+ Blue
system.
When using the NC4+ Blue system, basic safety precautions must always be
followed to reduce the risk of fire, electric shock and personal injury,
including the following:
- Read all instructions before operating this product.
- The device must only be installed and used by competent, trained personnel.
- Use eye protection to protect against mechanical hazards, coolant and swarf.
- Avoid inhalation of coolant vapor from the machine tool.
- Do not block the air exiting from the transmitter, receiver or air blast apertures.
- The sound power emitted by the air blast equipment can range from 70.3 dB at 3.0 bar (43.51 psi) to 78.2 dB at 6.0 bar (87.02 psi). It is the responsibility of the integrator to ensure a suitable noise assessment is performed when the equipment is put into use.
- Prevent direct exposure of the eyes to the laser beam. Ensure that the beam is not reflected into the eyes via any reflective surface.
Software and user information
For available software, see the Probe software for machine tools – programs
and features data sheet (Renishaw part no. H-2000-2298). For more information,
see www.renishaw.com.
Machine tool apps
Smartphone apps provide information at a user’s fingertips in a simple,
convenient format. Available globally in a wide range of languages, our free-
of-charge apps give users the following information:
NC4 app
Configuration (including wiring), maintenance, and troubleshooting of NC4
systems.
GoPro be app Programming of Renishaw probing systems (including NC4).
Renishaw apps are available in China via Baidu and Tencent.
On-machine apps can be seamlessly integrated with a wide range of CNC
controllers. Apps are installed onto a Microsoft® Windows® -based CNC
controller or a Windows tablet connected to the controller via Ethernet.
With touch interaction and intuitive design, smartphone and on-machine apps
provide significant benefits to machine tool probe users.
For more information, visit
www.renishaw.com/machinetoolapps.
http://www.renishaw.com/machinetoolapps
Probe status LED function
For more information on these LED sequences and modes of operation, see the NC4+ Blue non‑contact tool setting system installation and maintenance guide (Renishaw part no. H-6435-8501).
Laser safety and warning labels
*Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1
Ed. 3., as described in Laser Notice No. 56,
- Except for deviations pursuant to Laser Notice No. 50 dated June 24 2007 dated May 8, 2019.
Location of the laser aperture
CAUTION – Laser safety
The access panel is to be removed for service purposes only using the special
tool supplied.
Before removing the panel, switch off the electrical power to the transmitter
unit to avoid exposure to the laser beam.
CAUTION symbol
The caution symbol on the access panel denotes the following:
CAUTION – Class 3R Laser radiation when open. Avoid direct eye exposure.
This text is not included on the access panel due to the limited space
available.
© 2019–2021 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or
transferred to any other media or language, by any means, without the prior
written permission of Renishaw.
Renishaw plc. Registered in England and Wales. Company no: 1106260. Registered
office: New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR, UK.
Disclaimer
WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT
PUBLICATION, ALL WARRANTIES, CONDITIONS, REPRESENTATIONS, AND LIABILITY,
HOWSOEVER ARISING, ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW.
RENISHAW RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AND TO THE
EQUIPMENT, AND/OR SOFTWARE AND THE SPECIFICATION DESCRIBED HEREIN WITHOUT
OBLIGATION TO PROVIDE NOTICE OF SUCH CHANGES.
Trademarks
RENISHAW® and the probe symbol are registered trademarks of Renishaw plc.
Renishaw product names, designations, and the mark ‘apply innovation’ are
trademarks of Renishaw plc or its subsidiaries.
Google Play and the Google Play logo are trademarks of Google LLC.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S.
and other countries. App Store is a service mark of Apple Inc., registered in
the U.S. and other countries.
Other brands, products, or company names are trademarks of their respective
owners.
Warranty
Unless you and Renishaw have agreed and signed a separate written agreement,
the equipment and/or software are sold subject to the Renishaw Standard Terms
and Conditions supplied with such equipment and/or software, or available on
request from your local Renishaw office.
Renishaw warrants its equipment and software for a limited period (as set out
in the Standard Terms and Conditions), provided that they are installed and
used exactly as defined in associated Renishaw documentation. You should
consult these Standard Terms and Conditions to find out the full details of
your warranty.
Equipment and/or software purchased by you from a third-party supplier is
subject to separate terms and conditions supplied with such equipment and/or
software. You should contact your third-party supplier for details.
China RoHS
For more information, on China RoHS visit:
www.renishaw.com/mtpchinarohs
REACH regulation
Information required by Article 33(1) of Regulation (EC) No 1907/2006
(“REACH”) relating to products containing substances of very high concern
(SVHCs) is available at:
www.renishaw.com/REACH
Disposal of waste electrical and electronic equipment (WEEE)
The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, contact your local waste disposal service or Renishaw distributor.
EU declaration of conformity
Renishaw plc hereby declares that the NC4+ Blue non-contact tool setting system is in compliance with the essential requirements and other relevant provisions of:
- the applicable EU directives
- the relevant statutory instruments under UK law
The full text of the declaration of conformity is available at:
www.renishaw.com/mtpdoc
FCC Information to user (USA only)
47 CFR Section 15.19
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. 47 CFR Section 15.21
The user is cautioned that any changes or modifications not expressly approved
by Renishaw plc or an authorized representative could void the user’s
authority to operate the equipment.
47 CFR Section 15.105
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at their own expense.
ICES Information to user (Canada only)
This ISM device complies with Canadian ICES-001.
Cet appareil ISM est conforme à la norme ICES-001 du Canada.
Patents
Features of the NC4+ Blue non-contact tool setting system and features of
similar products are the subject of one or more of the following patents
and/or patent applications:
CN 100394139 | WO 2020/074866 |
---|---|
EP 1502699 | US 7312433 |
JP 4520240 |
Renishaw plc
New Mills, Wotton-under-Edge
Gloucestershire, GL12 8JR
United Kingdom
T +44 (0)1453 524524
F +44 (0)1453 524901
E uk@renishaw.com
www.renishaw.com
For worldwide contact details, visit
www.renishaw.com/contact
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>