Specifications

  • Product: Orion-Tr Smart DC-DC charger non-isolated
  • Power: 360/400 Watt
  • Battery Charge Algorithm: 3-stage
  • Website: www.victronenergy.com

Product Usage Instructions

Remote On/Off

A remote on/off switch or relay contact can be connected to a two-pole connector. Alternatively, the H terminal (right) of the two-pole connector can be switched to battery plus, or the L terminal (left) of the two-pole connector can be switched to battery minus (or the chassis of a vehicle, for example).

Short Circuit Protection and Parallel Connection

All models are short-circuit proof and can be paralleled to increase output current. An unlimited number of units can be connected in parallel.

Temperature and IP Protection

High temperature protected – The output current will reduce at high ambient temperature. IP43 protection when installed with the screw terminals oriented downwards.

Installation

Screw terminals – No special tools are needed for installation.

Input Fuse

The input fuse is not replaceable.

Specifications Overview

  • Input Voltage Range: 10-35 V
  • Nominal Output Voltage: 12.2 V (12V models), 24.2 V (24V  models)
  • Output Voltage Adjust Range: 10-15 V (12V models), 20-30 V (24V models)
  • Efficiency: 87% – 89%
  • Maximum Cable Cross-section: Depending on the model, up to 60 A
  • Weight: 1.6 kg – 1.8 kg
  • Dimensions: 130 x 186 x 80 mm
  • Protection Category: IP43 (electronic components), IP22 (connection area)

victron-energy-24-12-30A-Orion-TrSmart-DC-DC-Charger-
fig-1 victron-
energy-24-12-30A-Orion-TrSmart-DC-DC-Charger-fig-2 victron-energy-24-12-30A-Orion-TrSmart-DC-
DC-Charger-fig-3

Bluetooth Smart enabled

• Any Bluetooth-enabled smartphone, tablet, or another device can be used to monitor, change settings, and update the charger when new software features become available.
• Instant Readout: The VictronConnect App can display key data, including warnings and alarms, on the Device list page without the need to connect to the product.

Fully programmable

  • Battery charge algorithm (configurable) or fixed output.
  • Smart alternator compatibility: engine running detection mechanism.

Adaptive 3-stage charge algorithm: bulk – absorption – float

  • For lead acid batteries, it is important that during shallow discharges the absorption time is kept short in order to prevent overcharging of the battery. After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged.
  • For lithium batteries absorption time is fixed, default 2 hours.
  • Alternatively, a fixed output voltage can be chosen.

Remote on/off

  • A remote on/off switch or relay contact can be connected to a two-pole connector.
  • Alternatively, the H terminal (right) of the two-pole connector can be switched to battery plus, or the L terminal (left) of the two pole connector can be switched to battery minus (or the chassis of a vehicle, for example).
  • All models are short circuit proof and can be paralleled to increase output current
  • An unlimited number of units can be connected in parallel.

High temperature protected

The output current will reduce at high ambient temperatures.

IP43 protection

When installed with the screw terminals oriented downward.

Screw terminals

No special tools are needed for installation.

Input fuse (not replaceable)

victron-energy-24-12-30A-Orion-TrSmart-DC-DC-Charger-
fig-4

victron-energy-24-12-30A-Orion-TrSmart-DC-DC-Charger-
fig-5

Frequently Asked Questions (FAQ)

Q: Can I connect multiple units in parallel?

A: Yes, all models are designed to be paralleled to increase the output current. An unlimited number of units can be connected in parallel.

Q: Is the input fuse replaceable?

A: No, the input fuse is not replaceable.

Q: What is the operating temperature range of the product?

A: The operating temperature range is specified as per the user manual and should be adhered to for optimal performance.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

victron energy User Manuals

Related Manuals