levenhuk Ermenrich Zing TC14/TC17 Digital Multimeter User Manual
- July 29, 2024
- levenhuk
Table of Contents
levenhuk Ermenrich Zing TC14/TC17 Digital Multimeter User Manual
- NCV sensor
- Warning indicator
- Flashlight
- VA display
- FUNC (Function) button
- Battery compartment
- H (Data hold) button
- INPUT jack (+)
- COM jack (-)
- Flashlight button
- Power button
Please carefully read the safety instructions and the user manual before using this product. Use the device only as specified in the user manual. Keep away from children.
The kit includes: digital multimeter, test leads (red and black), user manual, and warranty.
Getting started
- Unscrew the battery compartment cover screws and remove the cover.
- Insert 2 AAA batteries according to the correct polarity.
- Replace the battery compartment cover and tighten the screws.
- Press and hold the Power button (11) for 2 seconds to turn the device on or off.
Safety instructions
The multimeter complies with the IEC61010-1, Cat. III 600V safety requirements for Category III measuring equipment when using in circuits up to 600V AC voltage and pollution level 2. To avoid electric shock or personal injury, strictly observe the following safety instructions:
- Use extreme caution when measuring voltages above 30V AC (RMS), 42V AC (peak), or 60V DC, it is life threatening.
- To avoid electrocution and device damage, do not measure voltages higher than 600V.
- Use only properly functioning probes and test leads with intact insulation. Keep your fingers behind the safety guards on the probes.
- Do not use the device in environments with explosive gases, vapors, or high humidity.
- Connect the neutral/ground wire first, then the phase wire. Disconnect in reverse order.
- Disconnect the test leads before opening the battery compartment. Do not use the device with the open battery compartment or when it is disassembled.
- Do not ground yourself when taking measurements. Avoid contact with possible ground sources.
- Follow local and national safety regulations. Use personal protective equipment when working with exposed live parts.
Data hold
During a measurement, press the H button (7) to turn on data hold function and
display the current reading. The H icon will appear on
the display. Press again to turn the function off and return to measurement
display.
Flashlight
Press the Flashlight button (10) to turn the flashlight on/off.
Auto power turn-off
When you press the Power button (11) to power on, the automatic turn-off
function is activated by default and the display shows the symbol. After 15
minutes without any key operation, the multimeter will turn off automatically
to save battery energy. To cancel the automatic turn-off function, press the
FUNC button (5) and the Power button (11) simultaneously. The symbol is not
displayed when the automatic turn-off function is cancelled.
Smart (Auto) measurement mode
The multimeter is turned on in Smart (Auto) measurement mode by default.
The symbol appears on the display. In this mode, DC voltage, AC voltage,
resistance, and continuity can be measured, and the multimeter can
automatically identify the measurement signal. Plug the black test lead into
the COM jack (9) and the red test lead into the INPUT jack (8).
Connect the probes to the measuring points or in parallel to the circuit to be
measured. The multimeter will automatically recognize the measured signal. If
the resistance is <50Ω, an acoustic signal will be emitted continuously. The
measurement results will appear on the VA display (4).
The minimum measured voltage in this mode is about 0.8V.
The minimum measured voltage in this mode is about 0.8V.
Professional (Manual) measurement mode
Press the FUNC button (5) to activate the manual mode. To return to the Smart
(Auto) mode, press and hold the FUNC button (5) for 3 seconds.
AC/DC voltage measurement
Press the FUNC button (5) to select the or function. symbol or symbol is
displayed accordingly. Plug the black test lead into the COM jack (9) and the
red test lead into the INPUT jack (8). Connect the probes to the measuring
points. The measurement results will appear on the VA display (4).
Resistance measurement
Press the FUNC button (5) to select the function. Plug the black test lead
into the COM jack (9) and the red test lead into the INPUT jack (8). Connect
the probes to the resistance measuring points of circuit or resistor. The
measurement results will appear on the VA display (4).
Continuity test
Press the FUNC button (5) to select the function. Plug the black test lead
into the COM jack (9) and the red test lead into the INPUT jack (8). Connect
the probes to the circuit or component to be tested. The measurement results
(circuit resistance) will appear on the VA display (4).
If the resistance is <50Ω, an acoustic signal will be emitted continuously and
the LED indicator (2) will glow.
Frequency measurement
Press the FUNC button (5) to select the Hz function. Plug the black test lead
into the COM jack (9) and the red test lead into the INPUT jack (8). Connect
the probes to the measuring points. The measurement results will appear on the
VA display (4).
Capacitance measurement (TC17 only)
Press the FUNC button (5) to select the function. Plug the black test lead
into the COM jack (9) and the red test lead into the INPUT jack (8). Connect
the probes to the capacitance to be measured. The measurement results will
appear on the VA display (4).
Diode test (TC17 only)
Press the FUNC button (5) to select the function. Plug the black test lead
into the COM jack (9) and the red test lead into the INPUT jack (8). Connect
the black test probe to the cathode side and the red test probe to the anode
side of the diode to be measured. If the polarity of the test probes is
reverse to the diode polarity, the OL (Overload) will appear on the display.
This can be used for distinguishing the anode and cathode side of a diode.
The measurement results will appear on the VA display (2). If the polarity of
the test probes matches the diode polarity, the measurement results (voltage
drop) will appear on the VA display (4).
Non-contact voltage detection (NCV)
Press the FUNC button (5) to select the NCV function. Slowly bring the NCV
sensor (11) close to the point to be detected. When the signal of a weak
electromagnetic field is detected, the “– – – L” will appear on the display,
the built-in buzzer will produce a slow beep sound, and the LED indicator (2)
will glow green. When the signal of a strong electromagnetic field is
detected, the “– – – H” will appear on the display, the built-in buzzer will
produce a quick beep sound, and the LED indicator (2) will glow red.
When using this function, remove the test leads from the jacks.
Live detection
Press the FUNC button (5) to select the Live function. Plug only the red test
lead into the INPUT jack (8). Connect the red test probe to the conductor to
be measured. When the signal of a weak electromagnetic field is detected, the
“– – – L” will appear on the screen, the built-in buzzer will produce a slow
beep sound, and the LED indicator (2) will glow green. When the signal of a
strong electromagnetic field is detected, the “– – – H” will appear on the
screen, the built-in buzzer will produce a quick beep sound, and the LED
indicator (2) will glow red.
Specifications
| TС14| TC17
---|---|---
DC voltage, range| 4V / 40V / 400V / 600V ±(0.5%+3)| 400mV / 4V / 40V / 400V /
600V ±(0.5%+3
AC voltage, range| 4V / 40V / 400V / 600V ±(0.8%+3
Resistance, range 1| 4000Ω / 40kΩ / 400kΩ / 4MΩ ±(1.0%+5)| 400Ω / 4kΩ / 40kΩ /
400kΩ / 4MΩ ±(1.0%+5)
Resistance, range 2| 40MΩ ±(1.5%+10)
Frequency, range| 4Hz / 40Hz / 400Hz / 4kHz / 40kHz / 200kHz ±(1.0%+3)| 4Hz /
40Hz / 400Hz / 4kHz / 40kHz / 400kHz / 4MHz ±(1.0% +3)
Capacitance, range| | 4nF / 40nF / 400nF / 4µF / 40µF / 400µF / 4mF ±(4.0%+5)
Operating temperature range| 0… +40°C / +32… 104°F0–80% RH–10… +60°C / +14…
140°F0–70% RH2pcs alkaline AAA batteries (1.5V)EN61010-1,-2-030;
EN61010-2-033; EN61326-1; Cat. III, 600V
Operating humidity range
Storage temperature range
Storage humidity range
Power supply
Safety rating
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Use the device only within the permitted range. Wipe the body regularly with
detergent or a damp cloth with detergent. Do not use solvent to clean the
device. Protect the device from sudden impact and excessive mechanical force.
Store the device in a dry cool place. Only use accessories and spare parts for
this device that comply with the technical specifications. If a part of the
device or battery is swallowed, seek medical attention immediately.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the
intended use. Always replace the whole set of batteries at one time; taking
care not to mix old and new ones, or batteries of different types. Clean the
battery contacts and also those of the device prior to battery installation.
Make sure the batteries are installed correctly with regard to polarity (+ and
–). Remove batteries from equipment that is not to be used for an extended
period of time. Remove used batteries promptly. Never short-circuit batteries
as this may lead to high temperatures, leakage, or explosion. Never heat
batteries in order to revive them. Do not disassemble batteries. Remember to
switch off devices after use. Keep batteries out of the reach of children, to
avoid risk of ingestion, suffocation, or poisoning. Utilize used batteries as
prescribed by your country’s laws.
Ermenrich Warranty
Ermenrich products, except for their accessories, carry a 5-year warranty
against defects in materials and workmanship. All Ermenrich accessories are
warranted to be free of defects in materials and workmanship for six months
from the purchase date. The warranty entitles you to the free repair or
replacement of the Ermenrich product in any country where a Levenhuk office is
located if all the warranty conditions are met. For further details, please
visit: levenhuk.com/warranty If warranty problems
arise, or if you need assistance in using your product, contact the local
Levenhuk branch.
References
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Levenhuk’s official website in Europe
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia