TSI 854051 Environmental Enclosure Installing Metrology Station User Guide

May 15, 2024
tsi

TSI 854051 Environmental Enclosure Installing Metrology Station

Product Information

Specifications:

  • Model: Lufft WS300/WS500 Metrology Station
  • Manufacturer: Lufft
  • Connector: MSTB 2,5/ 3-ST5,08 (P/N 1757022)
  • Power Connector: SPDB 2,5/ 2 (P/N 3040410)

Product Usage Instructions

Unpacking the Metrology Station:

  1. Unpack and verify that all items are present as per the list provided.

Installation:
NOTICE: Disconnect power from the instrument before starting the installation process.

  1. Remove the hole plug in the enclosure and install the cable gland and jam nut.
  2. Insert the green connector into the Thiamis 1000 Node RS-485 socket.
  3. Install the connector on the DIN rail inside the enclosure.
  4. Insert one end of the connection cable through the gland and tighten it around the cable.
  5. Attach the other end of the cable to the weather station using a 14-mm wrench.
  6. Insert the red and black wires into the connector.
  7. Attach RS-485/SDI-12 Communication Wires to the green connector using a small flat blade screwdriver.
  8. Refer to the weather station manual for mounting instructions and specifications.
  9. Reapply power to the instrument once installation is complete.
  10. Use Environet to pair the weather station to the Thiamis 1000 following the provided steps.

Frequently Asked Questions (FAQ):

  • Q: What tools are needed for installing the Metrology Station?
    A: You will need a small flat blade screwdriver and a 14-mm wrench for installation.

  • Q: How do I connect the Metrology Station to the weather station?
    A: Follow step 5 in the installation instructions to attach the RS-485/SDI-12 Communication Wires to the green connector.

  • Q: Where can I find the mounting instructions for the weather station?
    A: Refer to the weather station manual for detailed mounting instructions and specifications.

Quick Start Guide
This guide will help you quickly attach the 10 m connection cable included with the Lufft WS300 (TSIS PIN 854050)/ Lufft WSSOO (TSI’ PIN 854051) to the DustTrak”‘ Environmental Monitor.

CAUTION
Refer to the Manufacturer’s Manual and follow all instructions regarding; setup, installation, proper use, maintenance, safe , and troubleshooting

Tools Needed for Installation

  • Small Flat Blade Screw Driver (not included)
  • 14-mm Wrench

TSI-854051-Environmental-Enclosure-Installing-Metrology-Station-
fig-3

www.phoenixcontact.com

Installation

NOTICE
Disconnect power from the instrument. The instrument SHOULD NOT have power during this installation procedure.

  1. Remove the hole plug in the enclosure and install the cable gland and jam nut.
  2. One end of the 10 m connection cable for the metrology station has been stripped back and ends added for connections inside the enclosure.
  3. Insert the wire end of the cable through the gland. Tighten (hand tight) the gland around the cable to prevent leakage.
  4. Insert the red and black wires into the connector as shown.
  5. Attach RS-485/SDl-12 Communication Wires to green connector as shown. A small flat blade screw driver can be used to tighten the connector to the wires.
  6. . Insert the green connector into the Thiamis 1000 Node RS-485 socket.
  7. Install the connector as shown to the DIN rail inside the enclosure.
  8. Attach the other end of the cable to weather station. Tighten (hand tight) with a 14-mm open ended wrench (see figure to right).
  9. See the weather station manual for mounting instructions and specifications.
  10. Reapply power to the instrument.
  11. Environet can be used to pair the weather station to the Thiamis 1000.
    a. Click Add Sensor in the device configuration.
    b. Select Lufft from the pull-down menu andTSI-854051-Environmental-
Enclosure-Installing-Metrology-Station-fig-11

Knowledge Beyond Measure.

TSI Incorporated — Visit our website www.tsi.com for more information.
USA Tel: +1 800 680-1220
Tel: +44 149 4 459200
France Tel: +33 1 41 19 21 99
Germany Tel: +49 241 523030
India Tel: +91 80 67877200
China Tel: +86 10 8219 7688
Singapore Tel: +65 6595 6388
TSI and the TSI logo are registered trademarks of TSI Incorporated in the United States and may be protected under other country’s trademark registrations. Thiamis is a trademark of Netronix Inc.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals