TSI 9515 Air Velocity Digital Meter Low Temperature Range Instruction Manual
- June 1, 2024
- tsi
Table of Contents
- TSI 9515 Air Velocity Digital Meter Low Temperature Range
- Product Usage Instructions
- Start Seeing the Benefits of Registering Today
- LIMITATION OF WARRANTY AND LIABILITY
- Unpacking and Parts Identification
- Setting up
- Operation
- Maintenance
- Troubleshooting
- Specifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TSI 9515 Air Velocity Digital Meter Low Temperature Range
Specifications:
- Product Name: VelociCalcTM Air Velocity Meter
- Model: 9515
- Manufacturer: TSI Incorporated
- Warranty: 24 months for most components, specific warranty durations for sensors and pumps
- Website: www.tsi.com
- Address: 500 Cardigan Road, Shoreview, MN 55126, USA
- Fax Number: 651-490-3824
Product Usage Instructions
Warranty Information:
The VelociCalc Air Velocity Meter comes with a limited warranty covering defects in workmanship and materials. Refer to the operator’s manual for specific warranty durations for different components.
Calibration:
Ensure that the instrument is properly calibrated before use. If
calibration is required, follow the instructions provided in the manual.
Maintenance:
Regularly clean and maintain the meter according to the manual’s
recommendations to ensure accurate readings and prolong the lifespan of the
product.
Operating Instructions:
Follow the step-by-step operating instructions outlined in the operator’s
manual to accurately measure air velocity using the meter.
Troubleshooting:
If you encounter any issues while using the meter, refer to the
troubleshooting section in the manual for guidance on identifying and
resolving common problems.
Frequently Asked Questions (FAQ):
-
Q: What is the warranty period for hot-wire or hot-film sensors?
A: Hot-wire or hot-film sensors used with research anemometers are warranted for 90 days from the date of shipment. -
Q: Does the warranty cover calibration requirements?
A: This warranty does not cover calibration requirements. The seller warrants only that the instrument is properly calibrated at the time of manufacture. -
Q: Can I open the instrument for maintenance without voiding the warranty?
A: Opening the instrument by anyone other than a factory-authorized service centre may void the warranty unless specifically allowed in the manual for consumable replacement or cleaning.
P/N 1980555, Revision G
August 2023
Start Seeing the Benefits of Registering Today
Thank you for your TSI® instrument purchase. Occasionally, TSI® releases
information on software updates, product enhancements and new products. By
registering your instrument, TSI® will be able to send this important
information to you.
http://register.tsi.com
As part of the registration process, you will be asked for your comments on
TSI products and services. TSI’s customer feedback program gives customers
like you a way to tell us how we are doing.
Copyright
TSI Incorporated / 2007–2023 / All rights reserved.
Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA
Fax No.651-490-3824
LIMITATION OF WARRANTY AND LIABILITY
Effective February 2015
(For country-specific terms and conditions outside of the USA, please visit
www.tsi.com.)
Seller warrants the goods, excluding software, sold hereunder, under normal
use and service as described in the operator’s manual, to be free from defects
in workmanship and material for 24 months, or if less, the length of time
specified in the operator’s manual, from the date of shipment to the customer.
This warranty period is inclusive of any statutory warranty. This limited
warranty is subject to the following exclusions and exceptions:
- Hot-wire or hot-film sensors used with research anemometers, and certain other components when indicated in specifications, are warranted for 90 days from the date of shipment;
- Pumps are warranted for hours of operation as outlined in product or operator’s manuals;
- Parts repaired or replaced as a result of repair services are warranted to be free from defects in workmanship and material, under normal use, for 90 days from the date of shipment;
- Seller does not provide any warranty on finished goods manufactured by others or on any fuses, batteries or other consumable materials. Only the original manufacturer’s warranty applies;
- This warranty does not cover calibration requirements, and the seller warrants only that the instrument or product is properly calibrated at the time of its manufacture. Instruments returned for calibration are not covered by this warranty;
- This warranty is VOID if the instrument is opened by anyone other than a factory-authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning;
- This warranty is VOID if the product has been misused, neglected, subjected to accidental or intentional damage, or is not properly installed, maintained, or cleaned according to the requirements of the manual. Unless specifically authorized in a separate writing by Seller, Seller makes no warranty concerning and shall have no liability in connection with, goods which are incorporated into other products or equipment, or which are modified by any person other than Seller.
The foregoing is instead of all other warranties and is subject to the
LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR
PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. CONCERNING SELLER’S BREACH OF
THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO CLAIMS
OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED
INFRINGEMENTS. BUYER’S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE
PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER’S OPTION
REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND
THE LIMIT OF SELLER’S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES
CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT,
STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE
REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR
REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, THE SELLER WILL REPAIR OR
REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE
PRICE OF THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS,
BUSINESS INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL
DAMAGES. SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR
REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought
against Seller more than 12 months after a cause of action has accrued. The
goods returned under warranty to Seller’s factory shall be at Buyer’s risk of
loss, and will be returned, if at all, at Seller’s risk of loss.
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY
AND LIABILITY, which contains the complete and exclusive limited warranty of
Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified
or its terms waived, except by writing signed by an Officer of Seller.
Service Policy
Knowing that inoperative or defective instruments are as detrimental to TSI as they are to our customers, our service policy is designed to give prompt attention to any problems. If any malfunction is discovered, please contact your nearest sales office or representative, or call TSI’s Customer Service department at 800-680-1220 (USA) or (001 651) 490-2860 (International) or visit www.tsi.com.
Trademarks
TSI and the TSI logo are registered trademarks of TSI Incorporated in the
United States and may be protected under other country’s trademark
registrations.
Unpacking and Parts Identification
Carefully unpack the instrument and accessories from the shipping container. Check the individual parts against the list of components below. If anything is missing or damaged, notify TSI® Incorporated immediately.
- Carrying case
- Instrument
Setting up
Supplying Power to the Model 9515 VelociCalc™ Air Velocity Meter
The Model 9515 is powered with four size AA batteries.
Installing the Batteries
Insert four AA batteries as indicated by the diagram located on the inside of
the battery compartment. The Model 9515 is designed to operate with either
alkaline or NiMH rechargeable batteries, although it will not recharge NiMH
batteries. Battery life will be shorter if NiMH batteries are used. Carbon-
zinc batteries are not recommended because of the danger of battery acid
leakage.
Using the Telescoping Probe
The telescoping probe contains the velocity and temperature sensors. When
using the probe, make sure the sensor window is fully exposed and the
orientation dimple is facing upstream.
NOTICE
For temperature measurements, make sure that at least 3 inches (7.5 cm) of the
probe is in the flow to allow the temperature sensor to be in the air stream.
Extending the Probe
To extend the probe, hold the handle in one hand while pulling on the probe
tip with the other hand. DO NOT hold the cable while extending the probe as
this prevents the probe from extending.
Retracting the Probe
To retract the probe, hold the handle in one hand while pulling gently on the
probe cable with the other hand.
Operation
Keypad Functions
ON/OFF Key| Press to turn the Model 9515 on and off. During the power up
sequence, the display will show the following: Model Number, Serial Number,
Software Revision, and Last Date Calibrated.
---|---
ft/min / m/s Key| Pressing this key changes the display to read air
velocity.
°C / °F Key| Pressing this key changes the display to read temperature.
Changing Units| To change units, first put the desired measurement (air
velocity or temperature) on the display. Then press and hold the left,
unlabelled key for five seconds. Finally, use the pq and ENTER key to
select the units.
Maintenance
The Model 9515 requires very little maintenance to keep it performing well.
Recalibration
To maintain a high degree of accuracy in your measurements, TSI® recommends
that you return your Model 9515 to TSI® Incorporated for annual recalibration.
Please contact one of TSI’s offices or your local distributor to make service
arrangements and to receive a “Service Request” number. To fill out an online
“Service Request” form, visit TSI’s website at tsi.com/service.
U.S. & International
TSI Incorporated 500 Cardigan Road Shoreview MN 55126-3996
Tel : 800-680-1220
651-490-2860
Fax: 651-490-3824
Cases
If the instrument case or storage case needs cleaning, wipe it off with a soft
cloth and isopropyl alcohol or a mild detergent. Never immerse the Model 9515.
If the enclosure of the Model 9515 becomes broken, it must be replaced
immediately to prevent access to hazardous voltage.
Storage
Remove the batteries when storing the unit for more than one month to prevent
damage due to battery leakage.
Troubleshooting
Table 5-1 lists the symptoms, possible causes, and recommended solutions for
common problems encountered with Model 9515. If your symptom is not listed, or
if none of the solutions solves your problem, please contact TSI®
Incorporated.
Table 5-1: Troubleshooting the VelociCalc™ Model 9515
Symptom | Possible Causes | Corrective Action |
---|---|---|
No Display | Unit not turned on | Switch unit on. |
Low or dead batteries | Replace batteries. | |
Dirty battery contacts | Clean the battery contacts. | |
Velocity reading fluctuates unstable | Fluctuating flow | Reposition probe in |
less-turbulent flow
Instrument Error message appears| Fault in instrument| Factory service is
required on the instrument.
WARNING
Remove the probe from excessive temperature immediately: excessive heat can
damage the sensor. Operating temperature limits can be found in Appendix A,
Specifications.
Specifications
Specifications are subject to change without notice.
Velocity:
- Range: 0 to 4000 ft/min (0 to 20 m/s)
- Accuracy1&2: ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater
- Resolution: 1 ft/min (0.01 m/s)
Temperature:
- Range: 0 to 200°F (-18 to 93°C)
- Accuracy3: ±0.5°F (±0.3°C)
- Resolution: 0.1°F (0.1°C)
Instrument Temperature Range:
- Operating (Electronics): 40 to 113°F (5 to 45°C)
- Operating (Probe): 0 to 200°F (-18 to 93°C)
- Storage: -4 to 140°F (-20 to 60°C)
External Meter Dimensions:
3.3 in. × 7.0 in. × 1.8 in. (8.4 cm × 17.8 cm × 4.4 cm)
Meter Weight:
Weight with batteries: 0.6 lbs (0.27 kg)
Power Requirements:
Four AA-size batteries (included)
- Temperature compensated over an air temperature range of 40 to 150°F (5 to 65°C).
- The accuracy statement of ±5.0% of reading or ±5 ft/min (±0.025 m/s), whichever is greater, begins at 30 ft/min through 4000 ft/min (0.15 m/s through 20 m/s).
- Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F (0.03°C/°C) for change in instrument temperature.
TSI Incorporated – Visit our website www.tsi.com for more information.
- USA Tel: +1 800 680 1220
- UK Tel: +44 149 4 459200
- France Tel: +33 1 41 19 21 99
- Germany Tel: +49 241 523030
- India Tel: +91 80 67877200
- China Tel: +86 10 8219 7688
- Singapore Tel: +65 6595 6388
P/N 1980555 Rev G ©2023 TSI Incorporated Printed in U.S.A.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>