Specifications

  • Product Name: HydroTap Classic CS Tap
  • Available Finishes: Chrome, Brushed Chrome, Matte Black
  • Product Order Codes:
    • Chrome: 01034214
    • Brushed Chrome: 01034215
    • Matte Black: 01034216
  • Style : HydroTap Classic Tap (CS)
  • Hole Size: 1 – 3/8 / 35mm
  • Tap Height: 8 1/4 (209mm) or 13 13/16 (351mm) when installed with the optional font extension
  • Installation : Over sink as a secondary tap or on optional font/drip tray 10392 260
  • Flow Rate: Max 1.8 GPM / 6.81 pm
  • Sparkling Water Flow Rate: 0.4 gpm / 1.51 pm
  • Product Certifications: IAPMO – NSF/ANSI 372, 42, 53, CSA
  • B438.1, ASSE 1087; cUL; CEC ADA Compliant: Yes

Product Usage Instructions

Installation Requirements

The HydroTap is a pump-driven system, so the installation of the Tap must be within 3′ (0.9m) of the base command center. Installation on most countertops is straightforward; however, some stone countertops may require a specialized cutting service.

If using a drip tray (font) accessory, suitable drainage to trapped waste is required within 3′ (0.9m) of the installation. Sufficient space and clearance to install the HydroTap as detailed in the product installation guidelines is required.

Installation and connection of your HydroTap must be carried out by a qualified person, observing all local, state, & federal regulations.

Installation Steps

  1. Choose the desired location for the HydroTap installation, ensuring it is within 3′ of the base command center.
  2. If installing over a sink as a secondary tap, ensure there is enough space and clearance according to the product installation guidelines.
  3. If using a drip tray (font) accessory, ensure suitable drainage to a trapped waste is available within 3′ of the installation.
  4. Securely install the HydroTap following the provided installation guidelines.
  5. If installing on an optional font/drip tray, follow the additional installation instructions provided for the specific accessory.
  6. Connect the HydroTap to the base command center using the provided hose, ensuring proper sealing and connection.
  7. Test the HydroTap for functionality by turning on the water supply and checking for filtered chilled and sparkling water flow.

FAQ

  • Q: What finishes are available for the HydroTap Classic CS Tap?
  • A: The HydroTap Classic CS Tap is available in Chrome, Brushed Chrome, and Matte Black finishes.
  • Q: What are the product order codes for the HydroTap Classic CS Tap in different finishes?
  • A: The order codes are as follows:
    • Chrome: 01034214
    • Brushed Chrome: 01034215
    • Matte Black: 01034216
  • Q: Can the HydroTap Classic CS Tap be installed as a secondary tap?
  • A: Yes, the HydroTap Classic CS Tap can be installed over the sink as a secondary tap or on optional font/drip trays.
  • Q: What are the flow rates of the HydroTap Classic CS Tap?
  • A: The maximum flow rate is 1.8 gpm (6.81 lpm) for regular water and 0.4 gpm (1.51 lpm) for sparkling water.
  • Q: Is the HydroTap Classic CS Tap ADA compliant?
  • A: Yes, the HydroTap Classic CS Tap is ADA-compliant.

HydroTap Classic Chilled/Sparkling (CS) Tap

  • Elevate your home hydration with the HydroTap Classic CS Tap and enjoy instant access to filtered chilled and sparkling water from the tap.
  • This HydroTap Classic can be installed over the sink as a secondary tap or over either of our optional Classic Range Font/Drip Trays (Integrated or Raised).
  • The HydroTap Classic is available in three finishes: Chrome, Brushed Chrome, and Matte Black.

HydroTap Classic CS Tap – Available Finishes

Product Order Codes for HydroTap Classic CS Taps

  • HydroTap Classic CS Tap in Chrome: 01034214
  • HydroTap Classic CS Tap in Brushed Chrome: 01034215
  • HydroTap Classic CS Tap in Matte Black: 01034216

Installation Requirements
The HydroTap is a pump-driven system so the installation of the Tap must be within 3’ (0.9m) of the base command center. Installation on most countertops is straightforward however, some stone countertops may require a specialized cutting service.

If using a drip tray (font) accessory, suitable drainage to trapped waste is required within 3’ (0.9m) of the installation. Sufficient space and clearance to install the HydroTap as detailed in the product installation guidelines is required.

Installation and connection of your HydroTap must be carried out by a qualified person, observing all local, state,

HydroTap 120V CS G5 Command Center – Product Specs

Style: HydroTap Classic Tap (CS)
Hole Size: 1 – 3/8” / 35mm
Tap Height: 8 1/4” (209mm) or 13 13/16” (351mm) when installed with

the optional font extension
Installation:| Over sink as a secondary tap or on optional font/drip tray
Flow Rate:| Max 1.8 gpm / 6.81 lpm
Sparkling Water Flow Rate| 0.4 gpm / 1.51 lpm
Product Certifications:| IAPMO – NSF/ANSI 372, 42, 53, CSA B438.1, ASSE 1087; cUL; CEC
ADA Compliant:| Yes

Zip-WATER-01034214-HydroTap-Classic-CS-Tap-fig-11

Installation Requirements

  • Installation and connection of your HydroTap must be carried out by a qualified person, observing all local, state, & federal regulations.
  • You will require a suitable 110 -120V 50-60Hz, 15 amp power supply with a NEMA 5-15 electrical outlet within 5′ 9* (1.75m) of the product.
  • The HydroTap is a pump-driven system so the installation of the Tap must be within 3′ (0.9m) of the base command center. The
  • HydroTap is an air-cooled system so discrete cabinetry cut-outs are required for ventilation. Installation on most countertops is straightforward however, some stone countertops may require a specialized cutting service.
  • If using a drip tray (font) accessory, suitable drainage to trapped waste is required within 3′ (0.9m) of the installation. If you live in an area with hard water (more than 150 ppm), we recommend the installation of a scale filtration kit or a water softener. Sufficient space and clearance to install the HydroTap as detailed in the product installation guidelines is required,

Zip-WATER-01034214-HydroTap-Classic-CS-Tap-fig-13

Scan QR code to view the installation guide

Installation by Zip Professional Service is available in select metro areas and can be arranged with a phone call to 1-833-233-2358 or by emailing wecare@na.zipwater.com. Technical Installation assistance over the phone or video call can be obtained by calling our customer care line at 1-833-233-2358, Monday through Friday 8 am – 5 pm Central Time

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals