TSI 9545 VelociCalc Air Velocity Meter Instruction Manual
- June 4, 2024
- tsi
Table of Contents
9545 VelociCalc Air Velocity Meter
VelociCalc® Air Velocity Meter
Model 9545/9545-A
Operation and Service Manual
P/N 1980564, Revision F July 2022
www.tsi.com
Start Seeing the Benefits of Registering Today!
Thank you for your TSI® instrument purchase. Occasionally, TSI® releases
information on software updates, product enhancements and new products. By
registering your instrument, TSI® will be able to send this important
information to you.
http://register.tsi.com
As part of the registration process, you will be asked for your comments on
TSI products and services. TSI’s customer feedback program gives customers
like you a way to tell us how we are doing.
Copyright TSI Incorporated / 2007-2022 / All rights reserved.
Address TSI Incorporated / 500 Cardigan Road / Shoreview, MN 55126 / USA
Fax No. 651-490-3824
LIMITATION OF WARRANTY AND LIABILITY (effective February 2015) (For country-
specific terms and conditions outside of the USA, please visit www.tsi.com.)
Seller warrants the goods, excluding software, sold hereunder, under normal
use and service as described in the operator’s manual, to be free from defects
in workmanship and material for 24 months, or if less, the length of time
specified in the operator’s manual, from the date of shipment to the customer.
This warranty period is inclusive of any statutory warranty. This limited
warranty is subject to the following exclusions and exceptions:
a. Hot-wire or hot-film sensors used with research anemometers, and certain
other components when indicated in specifications, are warranted for 90 days
from the date of shipment;
b. Pumps are warranted for hours of operation as set forth in product or
operator’s manuals;
c. Parts repaired or replaced as a result of repair services are warranted to
be free from defects in workmanship and material, under normal use, for 90
days from the date of shipment;
d. Seller does not provide any warranty on finished goods manufactured by
others or on any fuses, batteries or other consumable materials. Only the
original manufacturer’s warranty applies;
e. This warranty does not cover calibration requirements, and seller warrants
only that the instrument or product is properly calibrated at the time of its
manufacture. Instruments returned for calibration are not covered by this
warranty;
f. This warranty is VOID if the instrument is opened by anyone other than a
factory authorized service center with the one exception where requirements
set forth in the manual allow an operator to replace consumables or perform
recommended cleaning;
g. This warranty is VOID if the product has been misused, neglected, subjected
to accidental or intentional damage, or is not properly installed, maintained,
or cleaned according to the requirements of the manual. Unless specifically
authorized in a separate writing by Seller, Seller makes no warranty with
respect to, and shall have no liability in connection with, goods which are
incorporated into other products or equipment, or which are modified by any
person other than Seller.
The foregoing is IN LIEU OF all other warranties and is subject to the
LIMITATIONS stated herein. NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR
PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO SELLER’S BREACH
OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID WARRANTY IS LIMITED TO
CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED
INFRINGEMENTS. BUYER’S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE
PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER’S OPTION
REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.
TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER OR BUYER, AND
THE LIMIT OF SELLER’S LIABILITY FOR ANY AND ALL LOSSES, INJURIES, OR DAMAGES
CONCERNING THE GOODS (INCLUDING CLAIMS BASED ON CONTRACT, NEGLIGENCE, TORT,
STRICT LIABILITY OR OTHERWISE) SHALL BE THE RETURN OF GOODS TO SELLER AND THE
REFUND OF THE PURCHASE PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR
REPLACEMENT OF THE GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR
REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO, WILL REFUND THE PURCHASE
PRICE OF
THE SOFTWARE. IN NO EVENT SHALL SELLER BE LIABLE FOR LOST PROFITS, BUSINESS
INTERRUPTION, OR ANY SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES.
SELLER SHALL NOT BE RESPONSIBLE FOR INSTALLATION, DISMANTLING OR
REINSTALLATION COSTS OR CHARGES. No Action, regardless of form, may be brought
against Seller more than 12 months after a cause of action has accrued. The
goods returned under warranty to Seller’s factory shall be at Buyer’s risk of
loss, and will be returned, if at all, at Seller’s risk of loss.
Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY
AND LIABILITY, which contains the complete and exclusive limited warranty of
Seller. This LIMITATION OF WARRANTY AND LIABILITY may not be amended, modified
or its terms waived, except by writing signed by an Officer of Seller.
Service Policy Knowing that inoperative or defective instruments are as
detrimental to TSI as they are to our customers, our service policy is
designed to give prompt attention to any problems. If any malfunction is
discovered, please contact your nearest sales office or representative, or
call Customer Service department at
800-680-1220 (USA) or (1)
651-490-2860 (International).
Trademarks TSI, the TSI logo, and VelociCalc are registered trademarks of TSI
Incorporated in the United States and may be protected under other country’s
trademark registrations. LogDat2 is a trademark of TSI Incorporated.
CONTENTS
CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION ………… 1
CHAPTER 2 SETTING-UP ……………………………………………………… 3 Supplying Power to the Model
9545/9545-A ……………………………. 3 Installing the Batteries ……………………………………………………… 3
Using the Optional AC Adapter …………………………………………. 3 Using the Telescoping Probe
………………………………………………… 3 Extending the Probe ………………………………………………………… 3 Retracting
the Probe………………………………………………………… 4 Connecting to a
Computer…………………………………………………….. 4
CHAPTER 3 OPERATION………………………………………………………. 5 Keypad Functions
………………………………………………………………… 5 Common Terms …………………………………………………………………… 5 Menus
………………………………………………………………………………… 6 DISPLAY SETUP ……………………………………………………………………… 6
SETTINGS …………………………………………………………………………….. 6 FLOW SET UP
………………………………………………………………………… 6 ACTUAL/STANDARD SETUP……………………………………………………….. 6
DATA LOGGING ……………………………………………………………………… 7 Measurements
………………………………………………………………… 7 Log Mode/Log Settings ……………………………………………………. 7
Delete Data…………………………………………………………………….. 7 % Memory ………………………………………………………………………
7 LogDat2TM Downloading Software …………………………………………. 8
CHAPTER 4 MAINTENANCE …………………………………………………. 9 Recalibration
……………………………………………………………………….. 9 Cases…………………………………………………………………………………. 9
Storage ………………………………………………………………………………. 9
CHAPTER 5 TROUBLESHOOTING……………………………………….. 11
APPENDIX A SPECIFICATIONS …………………………………………… 13
iii
(This page intentionally left blank) iv
Chapter 1 Unpacking and Parts Identification
Carefully unpack the instrument and accessories from the shipping container.
Check the individual parts against the list of components below. If anything
is missing or damaged, notify TSI® Incorporated immediately.
1. Carrying case 2. Instrument 3. USB cable 4. Downloading software
(available on TSI® website:
http://www.tsi.com/SoftwareDownloads).
1
(This page intentionally left blank)
2
Chapter 1
Chapter 2
Setting-up
Supplying Power to the Model 9545/9545-A The TSI® Model 9545/9545-A
VelociCalc® Air Velocity Meter is powered with four size AA batteries.
Installing the Batteries Insert four AA batteries as indicated by the diagram
located on the inside of the battery compartment. The Model 9545/9545-A is
designed to operate with either alkaline or NiMH rechargeable batteries,
although it will not recharge NiMH batteries. Battery life will be shorter if
NiMH batteries are used. Carbon-zinc batteries are not recommended because of
the danger of battery acid leakage.
Using the Optional AC Adapter When using the AC adapter, the batteries (if
installed) will be bypassed. Be sure to provide the correct voltage and
frequency, which is marked on the back of the AC adapter. The AC adapter will
not recharge the batteries.
Using the Telescoping Probe The telescoping probe contains the velocity,
temperature, and humidity sensors. When using the probe, make sure the sensor
window is fully exposed and the orientation dimple is facing upstream.
NOTICE For temperature measurements, make sure that at least 3 inches (7.5 cm)
of the probe is in the flow to allow the temperature sensor to be in the air
stream.
Extending the Probe To extend the probe, hold the handle in one hand while
pulling on the probe tip with the other hand. DO NOT hold the cable while
extending the probe as this prevents the probe from extending.
3
Retracting the Probe To retract the probe, hold the handle in one hand while
pulling gently on the probe cable with the other hand.
Connecting to a Computer Use the Computer Interface USB Cable provided with
the Model 9545/9545-A to connect the instrument to a computer for downloading
stored data.
For more information on how to download stored data see Chapter 3 section
titled LogDat2TM Downloading Software.
CAUTION This symbol is used to indicate that the data port of the Model
9545/9545-A IS NOT intended for connection to a public telecommunications
network. Connect the USB data port only to another USB port.
4
Chapter 2
Chapter 3 Operation
Keypad Functions
ON/OFF Key
Arrow () Keys (Enter) Key Arrow ( or ) and Menu Soft Keys
Press to turn the Model 9545/9545-A on and off. During the power up sequence
the display will show the following: Model Number, Serial Number, Software
Revision and Last Date Calibrated.
Press to scroll through choices while setting a parameter.
Press to accept a value or condition.
Press arrow keys to change choices while setting a parameter. Press the Menu
soft key to select the Menu selections, which are Display Setup, Settings,
Flow Setup, Actual/Std Set up, Data Logging and Calibration.
Common Terms
In this manual there are several terms that are used in different places. The
following is a brief explanation of the meanings of those terms.
Sample Test ID
Time Constant
Consists of all of the measurement parameters stored at the same time.
A group of samples. The statistics (average, minimum, maximum, and count) are
calculated for each test ID. The maximum number of test IDs is 100.
The time constant is an averaging period. It is used to dampen the display. If
you are experiencing fluctuating flows, a longer time constant will slow down
those fluctuations. The display will update every second, but the displayed
reading will be the average over the last time constant period. For example,
if the time constant is 10 seconds, the display will update every second, but
the displayed reading will be the average from the last 10 seconds. This is
also referred to as a “moving average”.
5
Menus
DISPLAY SETUP
Display setup menu is where you will setup the desired parameters to be
displayed on the running screen. With a parameter highlighted you can then use
the ON soft key to have it show up on the running screen or select the OFF
soft key to turn off the parameter. Use PRIMARY soft key to have a parameter
show up on the running screen in a larger display. Only one parameter can be
selected as a primary, and up to 2 secondary parameters can be selected at one
time.
SETTINGS
Settings menu is where you can set the general settings. These include
Language, Beeper, Select Units, Time Constant, Contrast, Set Time, Set Date,
Time Format, Date Format, Number Format, Backlight and Auto Off. Use the or
soft keys to scroll through the settings for each option and use the key to
accept settings.
FLOW SET UP
In Flow Setup mode, there are 4 types: Round Duct, Rectangle Duct, Duct Area,
and Horn. Use the or soft keys to scroll through the types and then press the
key to accept the desired type. To change the value, highlight the Enter
Settings option and press the key. Use the instructions below to change the
value of the type that you selected.
NOTICE
The horn numbers are the models of the horns. For example, 100 refers to a
horn model number AM 100. Only horns with Model numbers as follows can be used
with this function: AM 100, AM 300, AM 600, and AM 1200. If a horn model
number is chosen, the instrument will return to measuring mode and use a
preprogrammed curve to calculate flow rate from velocity.
ACTUAL/STANDARD SETUP
Choose Actual/Standard measurements and parameters in the Act/Std Setup menu.
Within this menu, the user can also select Standard Temperature, Standard
Pressure and a source for the actual temperature. The actual barometric
pressure must be entered to convert air velocity and volume measurements to
actual conditions.
6
Chapter 3
DATA LOGGING
Measurements
Measurements to be logged are independent of measurements on the display, and
must therefore be selected under DATA LOGGING Measurements.
Log Mode/Log Settings
You can set Log Mode to Manual, Auto-save or Cont-key.
· Manual mode does not automatically save data, but instead prompts the user
to save a sample.
· In Auto-save mode, the user manually takes samples that are automatically
logged.
· In Cont-key mode, the user starts taking readings and logging by pressing
the key. The instrument will continue taking measurements until the key is
pressed again.
· Auto-save and Cont-Key modes have the following additional Log Settings:
Mode
Log Settings
Auto-save
Log Interval
Cont-key
Log Interval
· Pressing the keys simultaneously will lock the keypad to
prevent unauthorized adjustments to the instruments. To unlock the keypad, press the keys simultaneously.
Delete Data Use this to delete all data, delete test or delete sample.
% Memory
This option displays the memory available. Delete All, under Delete Data, will
clear memory and reset the memory available.
Operation
7
LogDat2TM Downloading Software The Model 9545/9545-A comes with special
software called LogDat2TM Downloading Software, which is designed to provide
you with maximum flexibility and power.
LogDat2TM software and updates are available from the TSI® website at
http://www.tsi.com/SoftwareDownloads. Follow online instructions to download
software.
To download data from the Model 9545/9545-A, connect the supplied computer
interface USB cable to the Model 9545/9545-A and to a computer USB port. Then
run the LogDat2TM software. Within the LogDat2TM software, either select the
tests to be downloaded or double-click on a test to open it.
8
Chapter 3
Chapter 4
Maintenance
The Model 9545/9545-A requires very little maintenance to keep it performing
well.
Recalibration To maintain a high degree of accuracy in your measurements, we
recommend that you return your Model 9545/9545-A to TSI® Incorporated for
annual recalibration. Please contact one of TSI’s offices or your local
distributor to make service arrangements and to receive a “Service Request”
number. To fill out an online “Service Request” form, visit TSI’s website at
tsi.com/service.
U.S. & International TSI Incorporated 500 Cardigan Road Shoreview MN
55126-3996 Tel: 800-680-1220
651-490-2860 Fax:
651-490-3824
The Model 9545/9545-A can also be recalibrated in the field using the
CALIBRATION menu. These field adjustments are intended to make minor changes
in calibration to match a user’s calibration standards. The field adjustment
IS NOT intended as a complete calibration capability. For complete, multiple-
point calibration and certification, the instrument must be returned to the
factory.
Cases If the instrument case or storage case needs cleaning, wipe it off with
a soft cloth and isopropyl alcohol or a mild detergent. Never immerse the
Model 9545/9545-A. If the enclosure of the Model 9545/9545-A or the AC adapter
becomes broken, it must be replaced immediately to prevent access to hazardous
voltage.
Storage Remove the batteries when storing the unit for more than one month to
prevent damage due to battery leakage.
9
(This page intentionally left blank)
10
Chapter 4
Chapter 5
Troubleshooting
Table 5-1 lists the symptoms, possible causes, and recommended solutions for
common problems encountered with the Model 9545/9545-A. If your symptom is not
listed, or if none of the solutions solves your problem, please contact TSI®
Incorporated.
Table 5-1: Troubleshooting the Model 9545/9545-A
Symptom No Display
Possible Causes Unit not turned on Low or dead batteries
Dirty battery contacts
Velocity reading fluctuates / unstable
Fluctuating flow
Instrument Error Memory is full message appears
Fault in instrument
Corrective Action
Switch unit on.
Replace batteries or plug in AC adapter.
Clean the battery contacts.
Reposition probe in less-turbulent section or use longer time constant.
Download data if desired, then DELETE ALL memory.
Factory service required on instrument.
WARNING
Remove the probe from excessive temperature immediately: excessive heat can
damage the sensor. Operating temperature limits can be found in Appendix A,
Specifications.
11
(This page intentionally left blank)
12
Chapter 5
Appendix A
Specifications
Specifications are subject to change without notice.
Velocity Probe:
Range:
0 to 6000 ft/min (0 to 30 m/s)
Accuracy1&2: ±3% of reading or ±3 ft/min (±0.015 m/s),
whichever is greater
Resolution: 1 ft/min (0.01 m/s)
Duct Size: Range:
1.0 to 500 inches in increments of 0.1 in. (2.5 to 1270 cm in increments of 0.1 cm)
Volumetric Flow Rate:
Range:
Actual range is a function of actual velocity, and
duct size
Temperature from Velocity Probe:
Range:
14 to 140°F (-10 to 60°C)
Accuracy3: ±0.5°F (±0.3°C)
Resolution: 0.1°F (0.1°C)
Relative Humidity from Velocity Probe:
Range:
5 to 95% RH
Accuracy4: ±3% RH
Resolution: 0.1% RH
Wet Bulb Temperature from Velocity Probe:
Range:
40 to 140°F (5 to 60°C)
Resolution: 0.1°F (0.1°C)
Instrument Temperature Range:
Operating (Electronics): 40 to 113°F (5 to 45°C)
Operating (Probe): 14 to 140°F (-10 to 60°C)
Storage:
-4 to 140°F (-20 to 60°C)
Instrument Operating Conditions When Using the Optional AC Adapter: Altitude up to 4000 meters Relative humidity up to 80% RH, non-condensing Pollution degree 1 in accordance with IEC 664 Transient over voltage category II
13
Data Storage Capabilities:
Range:
12,700+ samples and 100 test IDs (one sample can
contain fourteen measurement types)
Logging Interval:
Intervals:
1 second to 1 hour
Time Constant: User selectable
Response Time: Velocity: Temperature: Humidity:
200 msec 2 minutes (to 66% of final value) <1 minute (to 66% of final value)
External Meter Dimensions: 3.3 in. 7.0 in. 1.8 in. (8.4 cm 17.8 cm 4.4 cm)
Meter Probe Dimensions:
Probe length:
40 in. (101.6 cm)
Probe diameter of tip: 0.28 in. (7.0 mm)
Probe diameter of base: 0.51 in. (13.0 mm)
Articulating Probe Dimensions:
Articulating section length:
6.0 in (15.24 cm)
Diameter of articulating knuckle: 0.38 in (9.5 mm)
Meter Weight: Weight with batteries: 0.6 lbs (0.27 kg)
Power Requirements: Four AA-size batteries (included) or AC adapter (optional) 9 VDC, 300 mA min.
1 Temperature compensated over an air temperature range of 40 to 150°F (5 to
65°C).
2 The accuracy statement of ±3.0% of reading or ±3 ft/min (±0.015 m/s),
whichever is greater, begins at 30 ft/min through 6000 ft/min (0.15 m/s
through 30 m/s).
3 Accuracy with instrument case at 77°F (25°C), add uncertainty of 0.05°F/°F
(0.03°C/°C) for change in instrument temperature.
4 Accuracy with probe at 77°F (25°C). Add uncertainty of 0.1% RH/°F (0.2%
RH/°C) for change in probe temperature. Includes 1% hysteresis.
14
Appendix A
Notes
Specifications
15
Notes
16
Appendix A
(This page intentionally left blank)
Specifications
17
TSI Incorporated Visit our website www.tsi.com for more information.
USA
Tel: +1 800 680 1220
UK
Tel: +44 149 4 459200
France Tel: +33 1 41 19 21 99
Germany Tel: +49 241 523030
India
Tel: +91 80 67877200
China
Tel: +86 10 8219 7688
Singapore Tel: +65 6595 6388
P/N 1980564 Rev F
©2022 TSI Incorporated
Printed in U.S.A.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>