FLUKE 902 FC True-rms Wireless HVAC Clamp Meter User Guide

June 4, 2024
FLUKE

FLUKE 902 FC True-rms Wireless HVAC Clamp Meter

FLUKE 902 FC True-rms
Wireless HVAC Clamp Meter product

TECHNICAL DATA

Fluke 902 FC True-rms Wireless HVAC Clamp Meter

If you are an HVAC technician, you need a reliable clamp meter to keep up with your demanding world. The Fluke 902 FC delivers the features necessary to diagnose and repair HVAC systems. Additionally, with Fluke Connect® you can trend mea-surements, create and send reports right from the field, safely stay away from live equipment while taking measurements, and more.

Measurement capability

  • 600 A ac current measurement
  • 600 V ac and dc voltage measurement
  • Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F)
  • 1000 µF capacitance measurement
  • DC Current measurement to 200 µA
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Resistance measurement to 60 kΩ
  • Min and max recording to capture variations automatically

Features

  • Get more done faster and safer than before by connecting your meter to Fluke Connect and capture measurements wirelessly. Save your measurement to Fluke Cloud™ storage for further analysis or comparison to earlier inspection data.
    • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes the arc blast zone risks, not you.
    • Instantly trend and monitor measurements live on your phone screen for better troubleshooting results.

LOG AND TREND MEASUREMENTS
Transmit results wirelessly via
Fluke Connect®

SAFETY RATING
CAT III 600V / CAT IV 300V
BACKLIT DISPLAY
For working in low-lighting spaces

HVAC SPECIFIC FEATURES
Extended resistance range to measure a broad set of thermistors, μA DC current range to measure flame sensor current, contact temperature, and capacitance

WARRANTY
Three-years

Features (continued)

FLUKE 902 FC True-rms Wireless HVAC Clamp Meter fig
3

  • Create and email reports right from the field. When team collaboration is needed use Fluke Connect ShareLive™ video call to share live measurements and discuss next steps with colleagues.
  • Don’t risk transcription errors, save your measurements directly to your meter from your smartphone with the press of a button.
  • CAT III 600V / CAT IV 300V safety rating
  •  TPAK magnetic hanging strap (optional) allows you to conveniently hang the meter while using the probes
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display
  • Three-year warranty
  • Soft carrying case
  • Auto shut-off maximizes battery life so the meter works when you need it
  • Measurement range feature automatically changes switch positions

Specifications

FLUKE 902 FC True-rms Wireless HVAC Clamp Meter fig
4

Specifications (continued)FLUKE 902 FC True-rms Wireless HVAC Clamp Meter
fig 5

Ordering information

902 FC HVAC Clamp Meter

Included
902 FC HVAC Clamp Meter
One pair TL75 Test leads
One 80BK Integrated DMM Temperature Probe Two AA alkaline batteries
Soft carrying case
Users’ manual
Statement of Calibration Practices

Optional accessories
TPAK Magnetic Hanging StrapFLUKE 902 FC True-rms Wireless HVAC Clamp Meter
fig 6FLUKE 902 FC True-rms Wireless HVAC
Clamp Meter fig 7

Set up and sustain preventive maintenance practices with ease to help you oversee your complex world with the Fluke Connect® system of software and over 40 wireless test tools.

  • Maximize uptime and make confident maintenance decisions with data you can trust and trace.
  • Save measurements to the Fluke Cloud™ and associate with an asset so your team can consult both historical and current measurements from one location.
  • Collaborate with ease by sharing your measurement data with team members with ShareLive™ video calls and emails.
  • Wireless one-step measurement transfer with AutoRecord™ measurements eliminates transcription errors, clipboards, notebooks and multiple spreadsheets.
  •  Generate reports with multiple measurement types to provide status or next step recommendations.
    Find out more at flukeconnect.com

FLUKE 902 FC True-rms Wireless HVAC Clamp Meter fig 8

All trademarks are the property of their respective owners. WiFi or cellular service required to share data. Smartphone, wireless service and data plan not included with purchase. First 5 GB of storage is free. Phone support details can be viewed at fluke.com/phones.
Fluke Connect is not available in all countries, check with your local Fluke representative.
4 Fluke Corporation Fluke 902 FC True-rms Wireless HVAC Clamp Meter

Fluke. Keeping your world up and running.®

  • Fluke Corporation
    PO Box 9090, Everett, WA 98206 U.S.A.

  • Fluke Europe B.V.
    PO Box 1186, 5602 BD

  • Eindhoven, The Netherlands
    For more information call:

  • In the U.S.A. 800-443-5853 or

  • Fax 425-446-5116

  • In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222

  • In Canada (800)-36-FLUKE or

  • Fax 905-890-6866

  • From other countries +1 425-446-5500 or Fax +1 425-446-5116
    Web access: http://www.fluke.com
    ©2015 Fluke Corporation.

  • Specifications subject to change without notice.

  • Printed in U.S.A. 12/2015 6006670a-en Modification of this document is not permitted without written permission from Fluke Corporation.