Blaze King AF20.2 Safety Clearances Instructions

March 18, 2024
Blaze King

**Blaze King AF20.2 Safety Clearances Instructions

**

This appliance must be installed in compliance with all local codes and regulations. Minimum clearances mayonly be reduced by means approved by the regulatory authority. Flue pipe must be 6” diameter and 24 MSG steel construction. Do not use aluminum or galvanized steel. Refer to local codes and pipe manufacturer specs for required minimum clearances. *In Canada, a minimum 18” (450 mm) clearance from single wall pipe is required.

RESIDENTIAL INSTALLATION| A| B| * C*| D| E**| F| J
---|---|---|---|---|---|---|---
Roof or Wall exit; Parallel or Corner min clearances| 12.75”324 mm| 6.5”166 mm| 26.125”664 mm| 15.875”404 mm| 6”153 mm| 18.125”461 mm| 37”940 mm
MOBILE HOME (USA) OR TRANSPORTABLE BUILDING (CAN) INSTALLATION
Roof exit only; Parallel or Corner min clearances
Outside Air Kit required| 12.75”324 mm| 6.5”166 mm| 26.125”664 mm| 15.875”404 mm| 6”153 mm| 18.125”461 mm| 37”940 mm

*
1 = 2.125″ (54 mm) in USA or 5.875″ (149 mm) in Canada                                                                      3ft recommended
2 =** 56.5″ (1435 mm) in USA or 58.5″ (1486 mm) in Canada

G = 2.625” (67 mm) in USA8” (203 mm) in Canada| H = 16” (406 mm) in USA18” (457 mm) in Canada| I = 0” (0 mm) in USA8” (203 mm) in Canada| * K = 18” (457 mm) for single wall pipe in Canada
---|---|---|---

FLOOR PROTECTION

This appliance does not require thermal hearth pad fl oor protection; however, if installed on a combustible fl oor, a non-combustible fl oor shield must be used. In the USA, this fl oor shield must extend 16” out from the front and 8” out from either side of the fuel-loading door. In Canada, to comply with CSA B365, any combustible covering beneath the appliance and/or within the area extending horizontally at least 18” (450 mm) beyond the appliance on any side equipped with a door, and at least 8” (200 mm) beyond the appliance on other sides, shall be protected by a continuous, durable, non-combustible pad that will provide ember protection. The 18” (450 mm) ember protection required on any side with a door shall extend for the full width of the appliance plus the 8” (200 mm) required on each side of the appliance without a door. Where an appliance is installed less than 8” (200 mm) from a wall, the ember pad need only extend to the base of the wall. An ember pad shall not be placed on top of a carpet unless the pad is structurally supported to prevent displacement and distortion.
A non-combustible shield is also required underneath the chimney connector and extend at least 2” on either side of the chimney connector. This shield does not need an insulation value, but must be listed under UL 1618-2009 (Type 1) and have a minimum size of:
32” x 40.125” (813 mm x 1019 mm) in USA or 42.75” x 50.125” (1086 mm x 1273 mm) in Canada.
Blaze King does not recommend adhesive based vinyl fl ooring in front of appliances due to thermal expansion and warping which could be permanent.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Blaze King User Manuals

Related Manuals