Ruijie RG-RAP2260H Wireless Access Point User Manual
- June 9, 2024
- RuiJie
Table of Contents
Ruijie RG-RAP2260H Wireless Access Point
Package Contents
Item | Quantity |
---|---|
RG-RAP2260(H) Access Point | 1 |
Mounting Bracket | 1 |
Phillips Screw | 4 |
Wall Anchor | 4 |
User Manual | 1 |
Certificate of Quality | 1 |
Hardware Features
Top View
Bottom View
Note: RESET Hole LAN1/2.5G/PoE Port LAN2/2.5G Pot 48 V DC input plug
PoE power supply: Connect one end of the Ethernet cable to the LAN1/2.5G/PoE
port of the access point, and the other end to a PoE-capable switch or other
power source equipment (PSE).
DC power supply: Connect the DC power adapter (48 V/1A) to the DC input plug
on the access point.
Technical Specifications
Item | Specification |
---|
Dimensions (W x D x
H)
| 230 mm x 230 mm x 48mm (9.06 inch x 9.06 inch x
1.89 inch, without the mounting bracket)
Data Rate| 2.4 GHz: up to 1148 Mbps
5 GHz: up to 4804 Mbps
Combined: 5952 Mbps
Operating Radio| 802.11 b/g/n/ax: 2.4 GHz to 2.4835 GHz
802.11 a/n/ac/ax: 5.150 GHz to 5.350 GHz, 5.470 GHz to 5.850 GHz
Antenna| Built-in omnidirectional antenna
Service Ports| Two 10/100/1000/2500 Mbps self-adaptive Ethernet ports
Restart/Reset| Supported
Status LED| Supported
Power Supply| There are three power supply modes available:
• Standard PoE: IEEE 802.3bt standard, backward compatible with the IEEE 802.3at standard
• 60 W Passive PoE adapter (Optional accessory)
• Local power supply: 48 V DC /1 A
Note: The access point is not 802.3af-compliant. (See Appendix for power supply modes and respective data
rate.)
Max Power
Consumption
| 40W
Environment| Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: -40°C to 70°C (-40°F to 158°F)
Operating humidity: 5% to 95% (non-condensing)
Storage humidity: 5% to 95% (non-condensing)
Weight| 1.8 kg (3.97 lbs, without the mounting bracket)
Color| Warm white
LED and Reset Hole
LED
| Status| Description
---|---|---
Solid blue| The access point is functioning properly
with no alarms.
Off| The access point is not receiving power.
Slow blinking| The access point is functioning properly but
there is an alarm generated.
Fast blinking| Possible cases:
1. Restoring the access point to factory settings.
2. Upgrading the firmware.
3. Handling alarms automatically.
4. Starting up the access point.
Reset Hole| Press and hold the pin
to the Reset hole for less than 2 seconds.
| Restart the access point.
---|---|---
Press and hold the pin to the Reset hole for more than 5 seconds.| Restore the
access point to factory settings.
Tools (Customer-supplied)
Mounting the Access Point without Security Lock
To mount the AP with the security lock, see Mounting the Access Point with Security Lock.
- Drill four holes at 53 mm (2.09 in) spacing on the wall or ceiling.
- Take out the mounting bracket from the packaging material.
- Secure the mounting bracket on the ceiling or wall by using screws.
- Connect the Ethernet cable to the LAN port on the rear of the AP.
- Align the square feet on the rear of the AP over the mounting holes on the bracket. Slide the AP into the holes until it clicks into place.
Mounting the Access Point with Security Lock (Optional)
Loosen the security screw to engage the security lock.
Align the square feet on the rear of the AP over the mounting holes on the bracket. Slide the AP into the mounting holes.
Caution:
Slide the AP into the mounting holes in the opposite orientation of the arrow
(UP) indicated on the bracket until it clicks into place. Do not forcibly
slide the Pinto the mounting holes on the brackets. After installation, verify
that the AP is properly secured on the bracket.
Removing the Access Point
- If the security lock is used, keep the top of the key against the edge of the mounting bracket (with the Ruijie logo on the key pointed upwards). Slide the key along with the four edges of the mounting bracket.
- Attempt to insert the key into the keyhole. It can only be inserted into one marked keyhole.
Removing the Wall-Mount AP
Hold the AP in your hands and push it upward and away from the bracket. Removing the Ceiling-Mount AP
Hold the AP in your hands and attempt to push it away from the bracket in each
orientation.
The AP can only be pushed out in one of the four orientations.
Configuring the Access Point
Method 1 (Recommended)
Scan the QR-code in the manual or on the device to download Ruijie Cloud App.
Find First time use Ruijie Cloud? Follow the guide on the App to configure the
network.
Method 2
-
Connect the access point to the SSID. If multiple devices exist in the network, use SSID @Ruijie-mXXXX. If only one device exists in the network, use SSID @Ruijie-sXXXX. You can also create a wired connection by connecting your PC to the Ethernet port of the access point with an Ethernet cable.
-
If there is only one Reyee device in the network, access http:/1192.168.120.1 via the browser. Otherwise, access http:/110.44.77.253.
In the latter case, configure your phone or PC with an IP address in the same network segment as 10.44.77.253, for example, 10.44.77.250. -
Click Start Setup to create network projects.
Appendix
Power Input | Local power supply: 48 V DC/1 A |
---|
Standard PoE: IEEE 802.3bt standard, backward compatible with the IEEE 802.3at
standard
Power Supply Mode| 2.4 GHz| 5 GHz| Data Rate| Max. Power
Consumption
IEEE 802.3bt Standard (Recommended)| 4×4| 4×4| 5952 Mbps| 40W
60 W Passive PoE
Adapter (Optional Accessory)| 4×4| 4×4| 5952 Mbps| 40W
Local Power Supply
(48 V DC /1 A)
| 4×4| 4×4| 5952 Mbps| 40W
IEEE 802.3at
Standard
| 2×2| 2×2| 2976 Mbps| 25W
Note: The access point is not 802.3af-compliant.
Documents / Resources
|
Ruijie RG-RAP2260H Wireless Access
Point
[pdf] User Manual
RG-RAP2260H, Wireless Access Point, RG-RAP2260H Wireless Access Point, Access
Point
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>