TKB Home Smart Energy Plug In Switch TZ88 Manual
- June 8, 2024
- TKB HOME
Table of Contents
- TKB Home
- Smart Energy Plug In Switch
- SKU: TZ88
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Watt Meter Report Period
- Parameter 2: KWH Meter Report Period
- Parameter 3: Threshold of current for Load Caution
- Parameter 4: Threshold of KWh for Load Caution
- Parameter 5: Restore switch state mode
- Parameter 6: Mode of switch off function
- Parameter 7: LED indication mode
- Parameter 8: Auto off timer
- Parameter 9: RF off command mode
- Technical Data
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TKB Home
Smart Energy Plug In Switch
SKU: TZ88
Quickstart
This is a ****
On/Off Power Switch
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1. Put your Z-Wave controller into inclusion mode by following the
instructions provided by the controller manufacturer. 2.Pressing On/Off button
three times within 2 seconds will enter inclusion mode.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Thisplug-inON/OFFswitchTZ88isasecurityenabledwirelessswitch,basedon Z-WavePlustechnology.Z-WavePlusenableddevicesdisplayingtheZ-Wave Plus logo can also be used with it regardless of the manufacturer, and can also be used in other manufacturers Z-Wave enabled networks. Remote On/Off control of theconnectedloadispossiblewithothermanufacturerswirelessController.Each switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to ensurethatthesignalisreceivedbyitsintendeddestinationbyroutingthesignal around obstacles and radio dead spots. Because TZ88 supports Security Command Class, it can learn with Secured controller. Its functionality and supported command classes is identical when included as a secure and non-secure device. Thisplug-inON/OFFswitchisabletodetectinstancewattage(3000W/CE/CN, 1500W/UL/TW/JP)andoverloadcurrent(14.5A)ofconnectedlightsorappliances. When detecting overload state, the Switch will be disabled and its On/Off button will belockoutofwhichLEDwillflashquickly.However,unplugandre-connectthe switch will reset its overload condition to normal status.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Pressing On/Off button three times within 2 seconds will enter inclusion mode. 2. Within 1 second, press On/Off button again for 5 seconds until LED is off.3. IDs are excluded.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1. Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter inclusion mode.
Exclusion
1. Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer. 2.Pressing On/Off button three times within 2 seconds will enter exclusion mode. 3. Node ID has been excluded.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Z-Wave Plus LifelineTheSwitchcanbesettosendreportstocontrolassociatedZ-
Wavedevices.It supports one association group with one node support for
Grouping 1. For group 1, the Switch will report its latest status to Z-Wave
Controller.Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT,
ALARM_REPORT
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Watt Meter Report Period
If the setting is configured for 1hour (set value =720), the TZ88 will
report its instant powerconsumptionevery1hourtoGroup1node.
Themaximumintervalto report its instant power consumption is 45 hours
(5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720
SettingDescription
1 – 32767 | 720*5s=3600s=1 hour |
---|
Parameter 2: KWH Meter Report Period
Ifthesettingisconfiguredfor1hour(setvalue=6),theTZ88willreportits
AccumulatedPowerConsumption(KW/h)every1hourtoGroup1node.The maximum interval
to report its Accumulated Power Consumption (KW/h) is 227.55 days
(10min*32767/1440=227.55 days).
Size: 2 Byte, Default Value: 6
SettingDescription
1 – 32767 | 6*10min=1 hour |
---|
Parameter 3: Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value,
if the setting value is 1300, when the load current of Relay1 over this value,
TZ88 will send current meter report to warn the Group1 node, the Range of the
setting value is from 10 to 1300,and the default value is 1300.
Size: 2 Byte, Default Value: 1300
SettingDescription
10 – 1300 | 1300*0.01A = 13A |
---|
Parameter 4: Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If
the setting value is 10000, when the Accumulated Power Consumption of Relay1
over this value, TZ88 will send KWH meter report to warn the Group1 node,
minimum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000
SettingDescription
Parameter 5: Restore switch state mode
Whenever the AC power return from lost, TZ88 will restore the switch state
which could be SWITCH OFFLAST SWITCH STATESWITCH ON. The default setting is
LAST SWITCH STATE.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | 0 : Switch off |
---|---|
1 | 1 : Last switch state |
2 | 2 : Switch on |
Parameter 6: Mode of switch off function
When the mode of switch On/Off is set to 0, any command of switch off will
be disabledandtheOn/Offfunctionofincludebuttonwillbedisabled.Thedefault
setting is enable mode.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | 0 : Disable |
---|---|
1 | 1 : Enable |
Parameter 7: LED indication mode
1. Show Switch StateWhen switch is on, LED is on. When switch is off, LED
is off. The default setting is Show Switch State. 2. Show Night modeWhen
switch is on, LED is off. When switch is off, LED is on.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | 1 : Show switch state |
---|---|
2 | 2 : Show night mode |
Parameter 8: Auto off timer
Whenever TZ88 switches to on, the auto off timer begin to count down. After
the timer decrease to zero, it will switch to off automatically. However if
Auto off timer is set as 0, the auto off function will be disabled. The
default setting is 0.
Size: 2 Byte, Default Value: 0
SettingDescription
0 | 0 : Disable auto off function |
---|---|
1 – 32767 | 1-0x7FFF : 1s ~ 32767s |
Parameter 9: RF off command mode
_Wheneveraswitchoffcommand,BASIC_SETBINARY_SWITCH_SET SWITCH_ALLOFF, is
received, it could be interpreted as 4 variety of commands. 1. Switch OffIt
switches to OFF state. The default setting is Switch Off. 2. IgnoreThe switch
off command will be ignored. 3. Switch ToggleIt switches to the inverse of
current state. 4. Switch OnIt switches to ON state.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | 0 : Switch off |
---|---|
1 | 1 : Ignore |
2 | 2 : Switch toggle |
3 | 3 : Switch on |
Technical Data
Hardware Platform | SD3502 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.00 |
Certification ID | ZC10-15050018 |
Z-Wave Product Id | 0x0118.0x0001.0x0011 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>