nuwave SENSORS AirSentric WB55 Wireless Indoor Air Quality Monitor User Manual
- June 9, 2024
- nuwave SENSORS
Table of Contents
AirSentric WB55 Wireless Indoor Air Quality Monitor
User Manual
Introduction
Before installing the AirSentric WB55 please give this manual a thorough read
through. The manual provides all of the important information to help you
successfully install the monitor and set up your online monitoring account.
Please retain this manual for future reference.
Hardware Configuration
The WB55 IAQ monitor comes equipped with a Zigbee wireless module, which
enables multiple monitors to be installed in a single environment/area. Each
unit then communicates back to a single internet enabled network point – the
Data Hub – which connects to the online monitoring account.
Hardware Installation
3.1 – Requirements for Installing the WB55 System
In order to install the system, there must be access to the following;
- Access to a power connection
- Access to a wired internet connection for the gateway
- Once power is supplied and the data gateway is connected the unit will need to be added to your online monitoring account. Please note that you only need to add the monitor device ID to the online software.
Note:
- Do not place your WB55 monitor near any heat source such as a radiator or at a window or direct sunlight.
- Place WB55 within range of your GY36 gateway.
- Place in an open space – avoid placing in areas where airflow may be obstructed
- Do not place where building occupants may be breathing directly at the monitor as this can have a disproportionate effect on sensor readings.
3.2 – Coverage Area and Placement
Monitor Installation Density:
Monitor installation density may vary depending on whether compliance with
a particular standard is being followed.
For example – The Well Building Standard guidelines recommend installing
monitors within a regularly occupied or common space in the building at the
following installation density:
- Projects with occupiable space of < 3250 m2 : 1 monitor per 325 m2 [3,500 ft2 ] in occupiable spaces (minimum 2)
- Projects with occupiable space of 3250-25,000 m2 : 1 monitor per 500 m2 [5,400 ft2 ] in occupiable spaces (minimum 10)
- Projects with occupiable space of > 25,000 m2 : 1 monitor per 1000 m2 [10,800 ft2 ] in occupiable spaces (minimum 50)
- Monitors must be distributed throughout the project and to the extent possible, representative of all HVAC zones, faces of a building, and regularly occupied spaces (e.g., open office areas, private offices, conference rooms and classrooms).
- For projects with multiple floors, monitors must be distributed across different floors, including the lowest and highest regularly occupied floor (excluding floors with only leased space in WELL Core and Core & Shell projects).
- Multifamily Residential projects may only utilize continuous monitoring pathways in nondwelling unit spaces—dwelling units must meet performance requirements through methods described in the Performance Testing Protocols for WELL section. To determine the monitor density for all other non-dwelling unit spaces, follow monitor density rate for the total area of the non-dwelling unit spaces only.
- For projects containing large open spaces (e.g., gyms, ball rooms, etc.), one monitor is sufficient for an area of up to 2,500 m2 [27,000 ft2 ] if there is evidence that the air is evenly mixed and contaminant sources are uniform (e.g., testing and balancing report indicating ventilation rate is even throughout the space, IAQ report indicating ventilation rate and contaminant levels are even throughout a space).
Installation Location Options:
-
Monitors are installed on a wall (vertically), at a height of 1.1-1.7 m [3.6-5.6 ft] above the finished floor.
-
Monitors are installed on a ceiling (horizontally). This placement option is only applicable in spaces, 1) with ceilings are no greater than 3.7 m [12 ft] above the finished floor, 2) that do not utilize displacement ventilation, and 3) there is evidence that the air is evenly mixed.
Evidence for evenly mixed air within a space is submitted in the sensor data package as a Letter of Assurance from an Engineer confirming that a space meets requirements of a ventilation guideline listed in A03: Ventilation Design Part 1: Ensure Adequate Ventilation. -
Monitors must be at least 1 m [3.3 ft] away from: doors, windows, air supply/exhaust outlets, air purifiers, or other potential influences (e.g., humidifiers, cleaning supplies, printers and photocopiers). To the extent possible, sampling points should be at least 5 m [16.4 ft] from exterior doors.
-
Additionally, monitors measuring temperature and relative humidity must be at least 1 m [3.3 ft] away from: direct sunlight, mechanical system supply outlets, fans, heaters or any other significant source of heat or cold.
Source: WELL Performance Verification Guidebook Q4 2021
3.3 – Mounting System
The WB55 can be wall mounted, using the included mounting plate. anchor
points on the baseplate.
It is recommended that where possible all 4 mounting holes are used when
securing the unit to a wall.
Please note: The unit is designed to be wall mounted vertically – long
term use of the unit in the incorrect orientation will result in dust build up
within the particle sensor (if a particle sensor is included in your
configuration).
Power Supply
The WB55 Sensor includes a 12V power supply adapter. The adapter converter can
operate at 100 – 240VAC (47-63Hz) and is compatible with the mains power
network of most continents.
Internet Connection
5.1 – Wireless Ethernet Gateway Connection
Your wireless monitor will need to be in range of the gateway – this can vary
per building from 20 metres to 100 metres depending on building fabric
- To set up the Gateway please connect the Ethernet cable provided to the DATA HUB and then connect to an Ethernet point or a spare Ethernet port on your router.
- Power on the device after connecting the supplied power supply. The device will power on automatically and establish a connection with the WB55 Sensor.
Please note: It can take up to 5 minutes for the gateway to pair with the monitor. You can check its status by viewing the sensor’s dashboard for data arriving online.
5.2 – Network Configuration
The DATA HUB will also by default automatically configure itself to your
network settings using DHCP. It is possible to configure the sensor to connect
to a static IP address. Please see page 12 of this manual to complete this
step.
Online Software Setup
Online Account Setup
To set up your online account to remotely monitor your IAQ monitor please
navigate to https://hex2.nuwavesensors.com/
on your computer internet browser.
On the webpage you will be prompted to sign in or create an account. As this
is your first time to access the account please click ‘Create Account’ just
under the sign in section. 6.2 – Account Registration
Please complete the form in order to complete the sign-up process. If you have
any issues, please contact support at:
info@nuwavesensors.com quoting the serial
number of your monitor and gateway (found on the sticker on the back of both
devices).
Create Account
Figure 4 → Account Registration Form
Setting up Your Sensor Using the Online Account
7.1 – Adding a monitor to your account
To add your new sensor, click ‘Add Device’ from the Manage Devices Page and
complete the form based on your sensor details;
- Device ID: Please enter the 16-digit sensor ID – this is the code on the sticker on the back of your sensor.
- Name: Example; Cleanroom 2A
- Label: Completing this field allows you to create groups of sensors based on your preference – example; 1st
Floor. You can also leave this blank if you do not wish to create a group.
Once you have competed the
above form click ‘Add Sensor’ button at the end of the form and your sensor
will be added. To add another sensor at any time please repeat the steps
above.
Viewing and Managing Sensor Data
After setting up the sensor and gateway correctly as well as adding your
sensor after logging in you should now start to see data arriving on the
sensor monitoring page. If you do not see data arriving after a period of 15
minutes please refer to the gateway configurations setting in the
troubleshooting section of this manual (page 17).
8.1 Sensor Status:
Here you can view the current VOC reading as well as the current temperature
and humidity reading from your sensor. 8.2 Graphing Options:
Data arriving on the website will be visible on the sensor graph. You can
change between graph views of 1 hour, 12 hour or 24 hours.
8.3 Sensor Indexes
Each sensor widget has a colour coded band that changes in response to
sensor measurements and indicates if this is considered to be good or bad air
quality on an air quality index. PM2.5:
The PM2.5 index changes colour in accordance with Now-Cast system used by the
World Air Quality Index Project. You can find more information here:
http://aqicn.org/here/
The index values are as follows:
AQI Category | Index Values | µg/m³ |
---|---|---|
Good | 0-50 | 0.0 – 12.0 |
Moderate | 51-100 | 12.1 – 35.4 |
Unhealthy for Sensitive Groups | 101-150 | 35.5 – 55.4 |
Unhealthy | 151 + | 55.5 + |
CO2:
The following index is used to determine the widget colour for the CO2 sensor
based on what is considered fair and poor levels of CO2. Temperature &
Humidity:
The following index is used to determine the optimal values for temperature
and humidity based on building occupant comfort levels and what is considered
to be healthy for the respiratory system.
| OK| Fair| Poor
---|---|---|---
Humidity| 35 – 65%| 25% – 35% /| <25% / >80%
65% – 80%
Temperature| 18 C -24 C| 15 C – 18 Cl| <15 C />28 QC
24 C- 28 C
8.4 Export CSV data:
For a longer-term view of the data or for detailed analysis you can
download a CSV file of your data at any time.
Due to download file size limitations this is limited at 1 weeks’ worth of
data per download. The link to download your data will be e-mailed to the
e-mail address registered with the account.
8.5 Sensor Management Settings
At the bottom of each sensor you will find the sensor management settings.
From here you can manage settings such as re-naming the sensor. Note: To save and
changes make sure and click ‘Submit Change’ at the bottom of the form.
User Profile Settings
On the settings page you can edit and manage your user account details
including;
- Change Password
- Change e-mail address associated with the account
- Address Location
Once any changes have been made click the ‘Save Changes’ button.
API
NuWave Sensors offers a RESTful API to monitor devices connected to our HEX
monitoring software.
Resources regarding the API for your installed monitors is available at the
following link address:
https://hex2.nuwavesensors.com/api/docs/
Gateway Network Configuration
The DATA HUB gateway is configured to use DHCP by default. This
automatically detects network settings on most standard networks and the
sensor will be able to send data online without changing any settings.
If you need to configure a port on your network for the gateway the port and
server address details are as follows:
Remote Port Number: 58122
Remote Server Address:
gateway2.nuwavesensordata.com
You can also edit the network settings and assign a static IP using the
gateway web interface of the gateway which is accessible using an internet
browser. To access the gateway you must know the IP address which can be found
using the MAC address of the gateway (located on the bottom of gateway).
When prompted, enter the following username and password;
Username: ‘admin’
Password: ‘admin’ or ‘alpha’
If you have any issues, please contact
info@nuwavesensors.com
Calibration
Our sensors come factory calibrated and in most cases your sensors can be
used for up to 3 years without calibration.
Calibration may be required in the following circumstances:
- You may require calibration for compliance purposes such as compliance with the Well Building Standard. In this case we recommend an annual calibration service
- If the devices are used in very polluted environments where a lot of dust is present this can have an impact on the particle sensor accuracy
- Exposure to high levels of chemicals can have an impact on the VOC or Formaldehyde sensor
- The temperature and humidity sensor will have a small amount of calibration drift annually which can be adjusted for with a calibration
Please contact us directly in order to arrange a calibration service at support@nuwavesensors.com
Important Precautions
Caution! This device is recommended for use indoors and in a dry location only.
- Avoid using WB55 in very dusty environments as dust build up may obstruct the air flow within the device.
- Take care when using WB55 to route the power cable in a way that reduces the risk of injury to others, such as by tripping or choking.
- Do not cover or obstruct vents around the WB55 sensor.
- Only use the power adapter supplied with WB55.
- Do not insert anything through the vents.
- Do not inject gas, dust or chemicals directly into the WB55 sensor.
- Do not use this device near water.
- Do not drop or subject the device to undue shock.
- Do not place in insect-infested areas. Insects can block vent openings to the sensors.
WB55 is designed to be maintenance free, but you should keep it clean and
avoid dust build up – especially around the air vents of the sensor which can
reduce performance.
To clean WB55:
- Turn off mains power and remove the power adapter plug from WB55.
- Wipe the outside with a clean, slightly damp cloth. Don’t use soap or solvents!
- Very gently vacuum around the vents of the WB55 sensor to remove dust obstructing the vent openings.
Note:
- Never use detergents or solvents on your WB55 sensor or spray air fresheners, hair spray or other aerosols near it.
- Do not place WB55 in water or let water get inside the WB55 sensor.
- Do not paint your WB55 sensor.
Recycling and disposal
The WEEE symbol on this product means that WB55 should be disposed of
separate from ordinary household waste at the end of its life in accordance
with local regulations. Please take WB55 to a collection point designated by
your local authority to be recycled to help conserve natural resources.
**Product Warranty:
**
Limited Product Warranty
THIS LIMITED WARRANTY CONTAINS IMPORTANT INFORMATION ABOUT YOUR RIGHTS AND
OBLIGATIONS, AS WELL AS LIMITATIONS AND EXCLUSIONS THAT MAY APPLY TO YOU AS
PART OF THE TERMS AND CONDITIONS OF SALE IN EFFECT AT THE TIME THAT YOU
PURCHASE A NUWAVE SENSOR TECHNOLOGY LIMITED PRODUCT.
What this warranty covers?
NuWave Sensor Technology Limited (“NuWave”) warrants to the original purchaser
of this WB55 sensor (the “Product”) shall be free of defects in design,
assembly material, or workmanship under normal use for a period of one (1)
year from the date of purchase (the “Warranty Period”). NuWave does not
warrant that the operation of the Product will be uninterrupted or error-free.
NuWave is not responsible for damage arising from failure to follow
instructions relating to the Product’s use. This Limited Warranty does not
cover software embedded in the Product and the services provided by NuWave to
owners of the Product. Refer to the licence agreement accompanying the
software for details of your rights with respect to their use.
Remedies
NuWave will repair or replace, at its option, any defective product free of
charge (except for shipping charges for the product). Any replacement hardware
product will be warranted for the remainder of the original warranty period or
thirty (30) days, whichever is longer. In the event that NuWave is unable to
repair or replace the product (for example, because it has been discontinued),
NuWave will offer either a refund or a credit towards the purchase of another
product from NuWave in an amount equal to the purchase price of the product as
evidenced on the original purchase invoice or receipt.
What is not covered by this warranty?
The warranty is null and void if the Product is not provided to NuWave for
inspection upon NuWave’s request, or if NuWave determines that the Product has
been improperly installed, altered in any way, or tampered with. The NuWave
Product Warranty does not protect against floods, lightning, earthquakes, war,
vandalism, theft, normal-use wear and tear, erosion, depletion, obsolescence,
abuse, damage due to low voltage disturbances such as brownouts, non-
authorised program or system equipment modification, alternation or other
external causes.
How to Obtain Warranty Service
Please review the online help resources at
nuwavesensors.com/support prior to seeking
warranty service. To get service for your WB55 sensor you must take the
following steps;
-
Contact NuWave Sensors customer support. Customer Support contact information can be found by visiting www.nuwavesensors.com/support
-
Provide the following to the customer support agent;
a. The serial number found on the back of your WB55 sensor
b. Where you purchased the product
c. When you purchased the product
d. Proof of payment -
Your customer service representative will then instruct you on how to forward your receipt and your WB55 as well as how to proceed with your claim.
It is likely that any stored data relating to the product will be lost or
reformatted during service and NuWave will not be responsible for any such
damage or loss.
NuWave reserve the right to review the damaged NuWave product. All costs of
shipping the Product to NuWave for inspection shall be borne by the purchaser.
Damaged equipment must remain available for inspection until the claim is
finalised. Whenever claims are settled NuWave reserves the right to be
subrogated under any existing insurance policies the purchaser may have.
Implied Warranties
EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES
INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE)
SHALL BE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
Some jurisdictions do not allow limitations on the duration of an implied
warranty, so the above limitation may not apply to you.
Limitation of Damages
IN NO EVENT SHALL NUWAVE BE LIABLE FOR INCIDENTAL, SPECIAL, DIRECT, INDIRECT,
CONSEQUENTIAL OR MULTIPLE DAMAGES SUCH AS, BUT NOT LIMITED TO, L OST BUSINESS
OR PROFITS ARISING OUT OF THE SALE OR USE OF ANY NUWAVE PRODUCT, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Statutory Rights
This warranty gives you specific legal rights, and you may have other rights,
depending on your jurisdiction. These rights are not affected by the
warranties in this Limited Warranty.
Appendix
16.1 – Troubleshooting
Problem | Possible Issue | Solution |
---|---|---|
No data arriving online | Outside of wireless range | The wireless range of the |
sensor can vary greatly depending on the building fabric and can vary by as
much as 20m to 100m. To test this please plug the WB55 SENSOR in close range
to the DATA HUB. Data should arrive
online after about 5 minutes. In this case the Data Hub will need to be re-
positioned closer to the sensor location.
| Ethernet Cable not firmly connected| Power off both the DATA HUB and WB55
SENSOR by plugging out the power supplies. Please ensure that the Ethernet
cable is firmly connected to both the DATA HUB gateway and the port on your
broadband router. Apply power to both devices and check to see if data
arrives after 5 minutes.
16.2 – WB55 Dimensions
16.3 – WB55 Specifications
The below specification is for SKU: AR10-B-120-A
Depending on your device / SKU individual sensors may not be included in your
configuration.
Particulate Matter | Particle Sizes | PM1.0, PM2.5, PM4.0, PM10 (0.3 – 10pm) |
---|---|---|
Mass concentration range | 0 — 1000 pg / m3 | |
PM Sensor Accuracy – PM1/2.5 | +/- 10% | |
PM Sensor Accuracy – PM4/ 10 | +/- 25% | |
Carbon Dioxide (CO2) | CO2 Sensor Range | 0 to 5000 ppm / 0.04 to 2% Volume CO2 |
CO2 Sensor Accuracy | +/-40ppm +/-3% of reading | |
TVOC Sensor | TVOC Sensor Range | 0-1000 ppb and VOC Index points (0-500) |
TVOC Sensor Accuracy | +/- 5 VOC Index points | |
Formatdhyde Sensor | CH2O Sensor Range | 0 to 5 ppm |
CH20 Accuracy | 10 ppb | |
Temperature | Temperature Range | 0 to 50°C |
Tempera ure Accuracy | (at-10 to 85 °C) ±1 °C (max) | |
Temp Sensor Stability | < 0.01 °C/Y | |
Humidity | RH Range | 5 to 95% RH continuous |
RH Accuracy | (at 0-90% RH) ± 5% RH (max) | |
RH Sensor Stability | < 0.25 %RH/yr | |
Size and Weight | Size | Size (LxWxD) – 4in (100mm) x 6in (150mm) x 1.8in (45mm) |
--- | --- | --- |
Weight | 320g (enclosure weight without power adapter) | |
Connectivity | Zigbee | Zigbee using GY36 Gateway (30m / 100ft range) |
Power | Power Supply | 100-240V International Adapter, DC 12V /- 10%, 42OmA |
Power Consumption | 250mA @ 12V | |
Operating Temperature | 0°C to 50°C ( 32 F to 122 F) | |
Accessories | Wall Mount Bracket is supplied | |
--- | --- | |
Calibration | Calibration service available (typically required every 3 years, |
annual service option available)
Software| Cloud Dashboard with no subscription fee for standard account
| API available
Additional Sensor Specifications:
CH20 Sensor Specifications:
Range | 0 – 5 ppm |
---|---|
Accuracy | 10 ppb |
Resolution | 0.01 ppm |
Warm up time | 3 minutes |
Sensor Lifetime | 2 years |
CH20 Sensor – Interfering Gases:
Gas | Concentration | Concentration output |
---|---|---|
NH3 | 5Oppm | Oppm |
C6H6 | 100ppm | 0.1ppm |
Cl2 | lOppm | 0.1ppm |
CH3CL | Sppm | 0.1ppm |
C3H60 | 100ppm | 0.2ppm |
C2H40 | lOppm | 0.5ppm |
SO2 | 2Oppm | 0.8ppm |
H2S | 100ppm | 3.7ppm |
H2 | 500ppm | S.Sppm |
C2HSOH | 131ppm | Sppm |
CH3OH | 42ppm | Sppm |
CH2O | Sppm | Sppm |
Technical Support
www.nuwavesensors.com/support
WB55 Manual — revision 2.3
References
- Worldwide Air Quality
- Contact Us - NuWave Sensors
- Contact Us - NuWave Sensors
- Nuwave | Login
- HEX API
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>