MICHELIN MB2420 Air Compressor
Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before operating or maintaining this compressor. Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions, An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures, Basic safety precautions are outlined in the “SAFETY” section of this Instruction Manual and in the sections which contain the operation and maintenance instructions, Hazards that must be avoided to prevent bodily injury or machine damage are idenlified by “WARNINGS” on the compressor and in this Instruction Manual, Never use this compressor in a manner that has not been specifically recommended by manufacturer, unless you first confirm that the planned use will be safe for you and others.
MEANINGS OF SIGNAL WORDS
- WARNING: indicates a potentially hazardous situations which, if ignored, could result in serious personal injury.
- CAUTION: indicates a hazardous situations which, if ignored, couls result moderate personal injury, or could cause machine damage
- NOTE: emphasizes essential information.
SAFETY
IMPORTANT SAFETY INSTRUCTIONS FOR USE OF THE COMPRESSOR
WARNING:
DEATH OR SERIOUS BODILY INJURY COULD RESULT FROM IMPROPER OR UNSAFE USE OF
COMPRESSOR. TO AVOID THESE RISKS, FOLLOW THESE BASIC SAFETY INSTRUCTIONS. READ
ALL INSTRUCTIONS
-
NEVER TOUCH MOVING PARTS
Never place your hands, fingers or other body parts near the compressor’s moving parts -
NEVER OPERATE WITHOUT ALL GUARDS IN PLACE
Never operate this compressor without all guards or safety features in place and in proper working order. If maintenance or servicing requires the removal of a guard or safely features, be sure to replace the guards or safety feature before resuming operation of the compressor. -
ALWAYS WEAR EYE PROTECTION
Always wear safety goggles or equivalent eye protection. Compressed air must never be aimed at anyone or any part of the body. -
PROTECT YOURSELF AGAINST ELECTRIC SHOCK
Prevent body contact with grounded surfaces such as pipes, radiators, ranges and refrigeration enclosures. Never operate the compressor in damp or wet locations, -
DISCONNECT THE COMPRESSOR
Always disconnect the compressor from the power source and remove the compressed air from the air tank before servicing, inspecting, maintaining, cleaning, replacing or checking any parts. -
AVOID UNINTENTIONAL STARTING
Do not carry the compressor while it is connected to its power source or when the air tank is filled with compressed air. Be sure the knob of the pressure switch in the “OFF” position before connecling the compressor to its power source. -
STORE COMPRESSOR PROPERLY
When not in use, the compressor should be stored in dry place. Keep out of reach of children. -
KEEP WORK AREA CLEAN
Keep work area clean, clear all work areas of unnecessary tools, debris, furniture etc. Keep the work place properly ventilated. Never use the compressor in the presence of flammable liquids or gases, The compressor may generate sparks during operation, Do not use the compressor in the presence of paints, fuels, chemicals, adhesives, and any other combustible or explosive materials -
KEEP CHILDREN AWAY
Do not let visitors contact compressor extension cord. All visilors should be kept safely away from work area. -
DRESS PROPERLY
Do not wear loose clothing or jewelry. They can be caught in moving parts, Wear protective hair covering to contain long hair. -
DON’T ABUSE CORD
Never yank it to disconnect from receplacle. Keep cord away from heat, oil and sharp edges, -
MAINTAIN COMPRESSOR WITH CARE
Follow instructions for lubricating (does not apply to Oilless). Inspect cords periodically and if damaged, have repaired by authorized service facility. Inspect extension cords periodically and replace if damaged. Always contact the authorized service center. -
OUTDOOR USE EXTENSION CORDS
When compressor in used outdoors, use only extension cords intended for use outdoors and so marked. -
STAY ALERT
Watch what you are doing. Use common sense, Do not operate compressor when you are lired, Compressor should never be used by you if you are under the influence of alcohol, drugs or medication that makes you drowsy. -
CHECK DAMAGED PARTS AND AIR LEAK
Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended funclion. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service center unless olherwise indicated elsewhere in this Instruction Manual. Have defective pressure switches replaced by authorized service center.
DO NOT USE COMPRESSOR IF SWITCH DOES NOT TURN IT ON AND OFF. -
USE THE COMPRESSOR ONLY FOR THE APPLICATIONS SPECIFIED IN THE FOLLOWING INSTRUCTION MANUAL FOR THE APPLICATIONS SPECIFIED IN THE FOLLOWING INSTRUCTION MANUAL
The compressor is a machine that produces compressed air. Never use the compressor for applications other than those specified in the instruction manual. -
HANDLE COMPRESSOR CORRECTLY
Operale the compressor according to the instructions provided herein. Never allow the compressor lo be operated by children, individuals unfamiliar wilh ils operation or unauthorized personnel. -
KEEP ALL SCREWS, BOLTS AND COVERS TIGHTLY IN PLACE
Keep all screws, bolts, and plates tightly mounted. Check their condilions periodically. -
KEEP MOTOR AIR VENT CLEAN
The motor air vent must be kept clean so that air can freely flow at all times, Check for dust build-up frequenlly. -
OPERATE COMPRESSOR AT THE RATED VOLTAGE
Operate the compressor at voltages specified on their nameplates. If using the compressor at a higher voltage than the rated vollage, it will result in abnormally fast motor revolution and may damage the unit and burn out the motor. -
NEVER USE A COMPRESSOR WHICH IS DEFECTIVE OR OPERATING ABNORMALLY
If the compressor appears lo be operating unusually, making strange noises, or otherwise appears defective, stop using it immediately and arrange for repairs by an authorized service center. -
DO NOT WIPE PLASTIC PARTS WITH SOLVENT
Solvents such as gasoline, thinner, benzine, carbon tetrachloride, and alcohol may damage and crack plastic parts, Do not wipe them with such solvents, Wipe plastic parts with a soft cloth lightly dampened with soapy water and dry thoroughly. -
USE ONLY GENUINE REPLACEMENT PARTS
Replacement parts not original may void your warranty and can lead to malfunction and resulting injuries, Genuine parts are available from your dealer. -
DO NOT MODIFY THE COMPRESSOR
Do not modify the compressor, Always contact the authorized service center any repairs. Unauthorized modification may not only impair the compressor performance but may also result in accident or injury to repair personnel who do not have the required knowledge and technical expertise to perform the repair operations correctly. -
TURN OFF THE PRESSURE SWITCH WHEN THE COMPRESSOR IS NOT USED
When the compressor is not used, lurn the knob of the pressure switch “0” (OFF), disconnect it from the power source and open the drain cock to discharge the compressed air from the air tank. -
NEVER TOUCH HOT SURFACE
To reduce the risk of burns, do not touch tubes, heads, cylinder and motors, -
DO NOT DIRECT AIR STREAM AT BODY
Risk of injury, do not direct air stream at persons or animals, -
DRAIN TANK
Drain tank daily or after 4 hours of use. Open drain fitting and tilt compressor lo emoty accumulated waler. -
DO NOT STOP COMPRESSOR BY PULLING OUT THE PLUG
Use the “O/l” (ON/OFF) knob of pressure switch. -
PNEUMATIC CIRCUIT
Use recommended pipes, pneumatic tools that withstand a pressure greater than or equal lo the maximum operating pressure of the compressor.
REPLACEMENT PARTS
When servicing use only identical replacement parts. Repairs should be
conducted only by authorized service center.
WARNINGS GROUNDING INSTRUCTIONS
- This compressor should be grounded while in use to protect the operator from electric shock. The single-phase compressor is equipped with a two-pole plus ground cable.
- Never disassemble the compressor or perform other connections in the pressure switch. Any repairs must only be performed by authorized service centers or other qualified centres. The green or green and yellow conductor in the cord is the grounding wire. Never connect the green wire to a live terminal. Before replacing the plug of the power cord, make sure you have connected the ground wire. Should you have any doubts, call a qualified electrician and check the ground connection.
EXTENSION CORD
Use only extension cords that have three-prong grounding type plugs. Replace
or repair damaged cord. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough lo carry the
current your product will draw. An undersized cord will cause a drop in line
voltage resulting in loss of power and overheating. The diameter of the
extension cable must be in proportion to its length: see table (tab 1).
Tab.1 SECTION VALID FOR A MAX LENGHT OF 20 mt single-phase
WARNING
Avoid electrical shock hazard. Never use this compressor wilh a damaged or
frayed electrical cord or extension cord, Inspect all electrical cords
regularly. Never use in near water or in any environment where electric shock
is possible.
SAVE THESE INSTRUCTION AND MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL!
OPERATION AND MAINTENANCE
NOTE: The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or altachments that differ from those on your own compressor.
INSTALLATION
- Remove the compressor from ils packing (fig.1), makes sure it is in perfect condition, checking if it was damaged during transport, and carry out the following operations.
- Fit the wheels and rubber tab on the tanks on which they are not already fitted, observing the instructions in fig 2. In case of inflatable wheels, the maximum inflation pressure must be of 1,6 bar (24 psi).
- Position the compressor on a flal surface or with a maximum permissible inclination of 10° (fig. 3), in a well aired place, protected against almospheric agents and not in a place subject to explosion hazard. If the surface is inclined and smooth, check if the compressor moves white in operation – if it does, secure the wheels with two wedges. If the surface is a bracket or a shelf top, make sure it cannot fall, securing it in a suitable way.
- To ensure good ventilation and efficient cooling, the compressor’must be at least 100 cm from any wall (fig, 4)-
USE INSTRUCTIONS
- Take care to transport the compressor correctly, do not overlurn it or lift it with hooks or ropes (fig. 5 – 6)
- Replace the plastic plug on the housing, with the oil plug supplied and check oil level (fig.7)
ELECTRICAL CONNECTION
Single-phase compressors are supplied with an electrical cable and a two-pole
- earth plug. The compressor must be connected to a grounded power socket
(fig.8).
NOTE: The equipment must be connected lo a maximum impedance of 0.37 Q.
STARTING
- Check that the mains power matches that indicated on the electrical data-plate (fig.9) the permissible tolerance range is +/-5%.
- Turn or press into position “0” (according to the type of pressure switch fitled on the appliance) the knob located on the upper section (fig.10). Fit the plug in the power socket and start the compressor, turning the pressure switch knob into position “I”,
- The compressor is fully automatic, and is controlled by the pressure switch which stops it when tank pressure reaches maximum value and restarts it when it falls lo minimum value. The pressure difference between maximum and minimum values is usually about 2 bar (29 psi). E.g.: lhe compressor stops when it reaches 8 bar (116 psi – maximum operating pressure) and restarts automatically when the pressure inside the tank drops lo 6 bar (87 psi), After connecting the compressor to the power line, load it to maximum pressure and check exactly how the machine is operaling.
- When the temperalure is <10 ° C it is recommended to make the first start with the tank unloaded (0 bar); il is recommended to depressurize the tank again, in case the compressor has stopped at low temperature within 30 minutes from the first start up.
NOTE: The head/cylinder/delivery tube unit can reach high temperatures. Take care when working near these parts, and do not touch them to avoid possible burns (fig.17),
IMPORTANT
The electro-compressors must be connected to a power socket protected by a suitable differential switch (thermal-breaker). The motor of compressors is equipped with an automatic thermal breaker located inside the winding – his slops the compressor when motor temperature reaches excessively high values. If the breaker is tripped, the compressors restarts automatically after 10 to 15 minutes, The same instruclions apply to compressors powered at 60 Hz.
ADJUSTING OPERATING PRESSURE (fig. 14)
You do not have to use the maximum operating pressure at all times. On the
contrary, the pneumatic tool being used often requires less pressure. On
compressors supplied with a pressure reducer, operaling pressure must be
correctly adjusted, Release the pressure reducer knob by pulling it up, adjust
pressure to the required value by turning the knob clockwise to increase
pressure and anti-clockwise to reduce it. When you have obtained optimum
pressure, lock the knob by pressing it downward. For pressure reducers
equipped without a pressure gauge, the set pressure can be seen on the
graduated scale located on the reducer body. On pressure reducers equipped
with a pressure gauge, pressure can be seen on the gauge itself.
WARNING: Some pressure regulators do not have “push to lock” therefore
simply turn the knob to adjust the pressure.
MAINTENANCE
- Before attempting any maintenance jobs on the compressor, make sure of the following:
- Master power switch in position “0”.
- Pressure switch and the control unit switches all off, in posilion “0”.
- No pressure in the air lank.
- Every 50 hours of duty: we advise you to dismantle the suction filter and clean the filtering element by blowing compressed air on it (fig. 13). You are recommended to replace the filter element at least once if lhe compressor operates in a clean environment, but more frequently if in a dusty environment.
- The compressor generates condensate water which accumulates in the tank. The condensate in the tank must be drained at least once a week, by opening the drain tap (fig. 12) under the tank. Take care
- if there is compressed air inside the cylinder, and waler could flow out with considerable force. Recommended pressure: 1 ÷ 2 bar max. Condensate of compressors that are oil lubricated must not be drained inlo the sewer or dispersed in the environment as it contains oil.
OIL CHANGES – TOPPING UP WITH OIL
- The compressor is filled with oil “GSP High-Performance”. We recommend a full change of oil in the pumping element within the first 100 hours of duty.
- Unscrew the oil plug on the housing cover, allow all the oil to low out, and re-screw the plug. Pour oil into the upper hole of the housing cover until it reaches the correct level showed by oil level light (fig. 13).
- Once a week check oil level of the pumping element and see if it needs topping up.
- For operation at ambient temperalure in the range -5°C to +40°C, use synthelic oil. The advantage of this oil is that is does not lose its characteristics either in winter or summer. Do not drain used oil into the sewer or dispose of it in the environment.
OBSERVE THIS TABLE FOR OIL CHANGES
WHAT TO DO IF SMALL MALFUNCTIONS OCCUR
-
Loss of air in valve under pressure switch
This trouble depends on poor tightness of the check valve – take the following action (fig. 16):- Discharge all pressure from the tank
- Unscrew the hexagon-head of the valve (A)
- Carefully clean both the rubber disk (B) and its seat
- Refit all parts accurately.
-
Air losses
These can be caused by poor lightness of a union – check all unions, wetting them with soapy water. -
Compressor turns but does not load
- This may be due to failure of the valves or of a seal (fig. 15): replace the damaged part
- Check if there is too much condensate water inside the tank.
-
Compressor no starting
If the compressor has trouble starting, check the following :- Does mains power match that of the data-plate? (fig, 9)
- Are power cable extensions of adequate diameter or length?
- Is the work environment too cold? (under 0°C)
- Is there oil in the housing lo ensure lubrication?
- Is power supplied to the electrical line (sockets well connected, thermal- breaker, fuses in good condition).
-
Compressor not stopping
If the compressor does not stop when maximum pressure is reached, the tank safety valve comes into operation, To repair the valve, contact your nearest service centre.
IMPORTANT-
Do not on any account unscrew any connection while the tank is pressurised always check if the tank is pressure free.
-
Do not drill holes, weld or purposely deform the compressed air tank.
-
Do not do any jobs on the compressor unless you have disconnected the power plug
-
Temperature in operaling ambient: 0°C +35°C.
-
Do not aim jets of water or inflammable liquids on the compressor.
-
Do not place inflammable objects near the compressor
-
During down-times, lurn the pressure switch to position “0” (OFF).
-
Never aim the airjet at people or animala.
-
Do not transport the compressor while the tank is pressurised.
-
Be careful with regard to some parts of the compressor such as the head and delivery lubes, as they can reach high temperatures. Do not touch these parts to avoid burns. (fig. 17)
-
Transport the compressor, lifting or pulling il with the appropriate grips or handles
-
Keep children and animals well away from the machine operaling area.
-
If using the compressor for painting:
-
Do not work in closed environments or near to naked flames;
-
Make sure there is adequate exchange of air at the place of work;
-
Protect your nose and mouth with an appropriale mask. (fig. 35)
-
If the electrical cable or plug are damaged, do not use the compressor and contact an authorised service centre to replace the faulty element with an original spare part.
-
If the compressor is located on a shelf or on a lop above floor height, it must be secured to prevent it falling while in operation.
-
Do not put objects or your hands inside the protective grilles lo avoid injury to yourself or damaging the compressor.
-
Do not use the compressor as a blunt object loward things or animals, to avoid serious damage.
-
When you have finished using the compressor, always remove the plug from the power socket.
NOTE: For the European market, the compressor tanks are manufactured to meet Directive CE2009/105. For the European market, the compressors are manufactured to meet Directive CE2006/42. -
Acoustic pressure measured free-field at a distance of 4m: +3dB(A) at maximum operating pressure
-
INSTRUCTION FOR USE AND MAINTENANCE OF THE PRESSURE VESSEL
The pressure vessel is intended to be used for storage of compressed air or nitrogen. It has been designed for mainly static applications. No account has been taken of loads due to wind, earthquakes or to reaclion moments or forces caused by the connections or piping. To ensure operalion of compressed air vessel under safe conditions, the proper use of same must be guaranteed. To this purpose, the user should proceed as follows:
- use the vessel properly, within the pressure and temperature limits stated on the nameplate and on the testing report, which must be kept with care;
- welding on the vessel is forbidden;
- assure that the vessel is complete with suitable and adequate safety and control fittings and replace them with equivalent ones in case of necessity. In particular, the safety valve must be correctly applied directly to the container with no possibility of interposition; it must also feature a discharge capacity greater than the amount of air that can be introduced into the container, it must be calibraled and sealed to the maximum allowable pressure indicated on the raling plate;
- fit the pressure vessel with vibration damping supports in order to avoid risk of the vessel being subject to detrimental vibrations during operation which could lead to fatigue failure.
- Corrosion must be prevented: depending on the conditions of use, condensation may accumulate inside the tank, and this must be emptied out every day. This may be done manually, by opening the draining tap, or by means of the automalic condensalion drainer, if fitled to the tank. During maintenance, periodically, the user or a Client Service expert must check the presence of internal corrosion and perform an external visual control. If the receiver is used with an Oilless compressor, or in surroundings that have a high level of humidity, or in adverse conditions (poor ventilation, corrosive agents,
- the inspections should be made more frequently. The legal checks have to be made in accordance with the local laws and rules where the receiver is used.
- Proceed sensibly and carefully, according to the existing prescriptions.
TAMPERING AND IMPROPER USE OF THE VESSEL ARE FORBIDDEN.
The users must comply with the laws on the operation of pressure equipment in
force in the relalive countries
HINTS FOR EFFICIENT OPERATION
- For efficient operation of the machine at full continuing load and al maximum operating pressure, make sure the temperature of the work environment indoors does not exceed +25°C.
- We advise you to use the compressor at 30% maximum duty per hour at full load as this ensures efficient operation of the product long term.
STORING THE PACKED AND UNPACKED COMPRESSOR
- For the whole time that the compressor is not used before unpacking it, store it in a dry place at a temperalure between +5°C and + 45°C and sheltered away from weather.
- For the whole time that the compressor is not used after unpacking it, while waiting to start it up or due to production stoppages, place sheets over it to protect it from dust, which may settle on the components.
- The oil is to be replaced and the operational efficiency of the compressor is to be checked if it is not used for long periods.
PNEUMATIC CONNECTIONS
Make sure you always use pneumatic lubes for compressed air with maximum
pressure characteristics that are adequate for the compressor. Do not attempt
to repair tubes if faulty.
WE RESERVE THE RIGHT TO MAKE ANY MODIFICATIONS WITHOUT PRIOR NOTICE WHENEVER
NECESSARY.
WIRING DIAGRAM
- A POWER SUPPLY
- P PRESSURE SWITCH
- T AUTOMATIC THERMAL PROTECTION SWITCH
- TM MANUAL AMPEROMETRIC PROTECTION
- C CONDENSER
- M MOTOR
- AU AUXILIARY WINDING
- AM STARTING WINDING
WARRANTY
- The electro-compressors are warranted for 24 months as from duly documented date of sale. This warranty is granted only to clients who are up to date with their payments. The compressor is warranted for normal operational duty, in a suitable place. The compressor must bo expertly installed. In the event of trouble caused by manufacturing faults occurling during the warranty period, the manulacturer shall replace free of charge parts recognised as faulty. Travelling and labour costs shall be, in any event, charged to the client.
- The following are excluded from the warranty: damage caused by poor maintenance, negligence and use under unsuitable conditions. The guarantee does not cover motors and all other electrical parts as well as parts subject to wear