Aquascape 45066 SLD Pond Pump Instruction Manual

May 15, 2024
Aquascape

Aquascape-logo

Aquascape 45066 SLD Pond Pump

Aquascape-45066-SLD-Pond-Pump-product

Specifications

  • Model Number: SLD Pond Pump
  • Maximum Flow Rate: 5,952 GPH/ 22,531 LPH (5000), 7,910 GPH/ 29,943 LPH (7000), 10,291 GPH/ 38,956 LPH (9000)
  • Maximum Head Height: 17′ / 5.2 m (5000), 25′ / 7.6 m (7000), 33′ / 10 m (9000)
  • Motor Type: Asynchronous
  • Wattage: 375 (5000), 605 (7000), 1006 (9000)
  • Amperage: 3.1 (5000), 5.2 (7000), 8.4 (9000)
  • Power Cord Length: 20′ / 6.1 m
  • Pump Discharge Diameter: 2 FPT
  • Pump Dimensions: 13L x 6.25W x 7H

Product Usage Instructions

Installation

  • NOTE:
    SLD pumps must always have constant, unrestricted access to water. Running the pump dry, or without sufficient water, can cause the internal components to overheat and damage the pump.

  • Recommended Accessories:
      Skimmer, Pondless Waterfall Vault

  • Tubing Size:
    It is recommended to use the largest diameter of tubing possible to achieve maximum water flow.

  • General Maintenance
    Regular maintenance of the SLD Pond Pump is essential for optimal performance. Ensure the pump is free from debris and check for any signs of wear or damage.

  • Troubleshooting
    If experiencing issues with the pump, refer to the troubleshooting section in the user manual for guidance on common problems and solutions.

  • Replacement Parts
    If replacement parts are needed, refer to the provided list of replacement parts in the user manual or contact Aquascape for assistance.

FAQ

  1. What is the warranty coverage for the SLD Pond Pump?
    The SLD Pond Pump comes with a 3-year warranty against manufacturing defects. Proof of purchase is required for warranty claims.

  2. Can I use an extension cord with the SLD Pond Pump?

  3. No, it is not recommended to use an extension cord with the SLD Pond Pump. Ensure the pump is connected to a properly grounded outlet.

  4. What should I do if the pump overheats?
    If the pump overheats, immediately turn it off and allow it to cool down before attempting to use it again. Ensure there is sufficient water flow to prevent overheating.

Thank you for choosing the Aquascape SLD Pond Pump.
At Aquascape, we connect people to water the way nature intended. Since 1991, we’ve been creating and field-testing water features in order to provide you with the most reliable products and best value in the water gardening industry.

Aquascape-45066-SLD-Pond-Pump- \(1\)

SLD Pond Pump
SLD Pond Pumps are professional-grade, solids-handling, submersible pumps made for continuous use in ponds, Pondless® Waterfalls, and other water feature applications. Asynchronous motor technology provides superior reliability, and a semi-vortex impeller design allows the pump to handle solids effectively, resulting in less maintenance and trouble-free performance. This instruction manual will guide you through the proper setup and recommended maintenance procedures to ensure long-term effectiveness.

Contact Us
For more information about our company or products, please visit our website at aquascapeinc.com or call US 866-877-6637 CAN 866-766-3426.

Find us on:

facebook.com/aquascapeinc
youtube.com/aquascape4
pinterest.com/aquascapeinc

SLD 5000, 7000 & 9000 Contents

No. Description
1. SLD Pond Pump

Aquascape-45066-SLD-Pond-Pump- \(3\)

Safety Information

WARNING : Risk of electric shock – This pump has not been approved for use in swimming pool or marine areas
WARNING: To provide continued protection against risk of electric shock, connect to properly grounded, ground fault circuit interrupter (GFCI) outlets only, using the following guidelines:

  • Have a qualified electrician install a properly grounded receptacle outlet, acceptable for outdoor use and protected from snow and rain.
  • Inspect cord before using.
  • Do not use an extension cord.
  • Any wiring of pumps should be performed by a qualified electrician to ensure code compliance and user safety.
  • Unplug pump at receptacle outlet when not in use or before removal from pond.
  • To reduce risk of electrical shock, all wiring and junction connections should be made per local codes. Requirements may vary depending on usage and location.
  • The power cable should be protected at all times to avoid punctures, cuts, bruises and abrasions.
  • Never handle power cords with wet hands.
  • Do not remove cord and strain relief. Do not connect conduit to pump.
  • Do not use power cable to lift pump.
  • Always operate the pump fully submerged; or if using in-line ensure a constant source of fresh water. Failure to do so may overheat the pump and cause it to fail, voiding the warranty.
  • Use only in fully assembled state, paying particular attention to ensure that both the outer and inner filter screens are attached to the pump. Failure to operate the pump without the filter screen will allow large debris to enter the pump and cause the pump to fail, voiding the warranty.
  • Do not wear loose clothing that may become entangled in the impeller or other moving parts.
  • Keep clear of suction and discharge openings. DO NOT insert fingers into pump with power connected.
  • Do not pump hazardous materials or liquids, such as oil, saltwater or organic solvents.
  • Do not block or restrict discharge.
  • Products returned must be cleaned, sanitized, or decontaminated, as necessary, prior to shipment to ensure that employees will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.

IMPORTANT: Aquascape, Inc. is not responsible for losses, injury, or death resulting from a failure to observe these safety precautions, misuse or abuse of pumps or equipment.

SLD Pond Pump Specs

Model Number 5000 7000 9000
Maximum Flow Rate 5,952 GPH/ 22 531 LPH 7,910 GPH/ 29 943 LPH 10,291 GPH/

38 956 LPH
Maximum Head Height| 17′ / 5,2 m| 25′ / 7,6 m| 33′ / 10 m
Motor Type| Asynchronous| Asynchronous| Asynchronous
Wattage| 375| 605| 1006
Amperage| 3.1| 5.2| 8.4
Power Cord Length| 20′ / 6,1 m| 20′ / 6,1 m| 20′ / 6,1 m
Pump Discharge Diameter| 2″ FPT| 2″ FPT| 2″ FPT
Pump Dimensions| 13″L x 6.25″W x 7″H| 13″L x 6.25″W x 7″H| 13″L x 6.25″W x 7″H

Installation

  • Do not submerge the pump directly in the pond. The pump is designed to be installed inside a skimmer, Pondless® Waterfall Vault, or large basin (Ex. 1).
    NOTE : SLD pumps must always have constant, unrestricted access to water. Running the pump dry, or without sufficient water, can cause the internal components to overheat and damage the pump.

  • Aquascape-45066-SLD-Pond-Pump- \(4\)SLD Pond Pumps provide a 2″ threaded discharge (FPT) which makes it easy to connect the pump to a wide variety of applications.

  • Attach a check valve or plumbing assembly to the discharge (Ex. 2).
    NOTE : Do not use tools to install the fittings into the pump discharge. Fittings need to be hand-tight only.
    NOTE : SLD pumps are designed to integrate Aquascape filters using the Dual Union Check Valve 2.0 – #48026 (Ex. 1 & Ex. 2). Aquascape-45066-SLD-
Pond-Pump- \(5\)

  • NOTE : It is recommended to use the largest diameter of tubing possible to achieve maximum water flow.

  • Plug the pump into an external GFI-rated electrical source (Ex. 3). Aquascape-45066-SLD-Pond-Pump- \(6\)

Winter Application

  • If running through winter conditions, check regularly to make sure it is functioning properly, and ice is not preventing water from reaching the pump.
  • In the event of a power failure, the pump should be removed to prevent any freeze damage to the pump or the piping.
  • If concerned about possible freeze damage, disconnect and remove the pump. Follow the maintenance/cleaning steps before storing the pump in a frost-free location.

General Maintenance

  • Remove the water chamber cover by removing the four Allen bolts (5mm Hex) and pulling gently (Ex. 4).Aquascape-45066-SLD-Pond-Pump- \(7\) NOTE : A gray gasket is installed on the impeller assembly (Ex. 5). Do not lose this gasket and ensure it is replaced upon re-installation.

  • Clean with fresh water, removing any existing debris or buildup.

  • Remove the impeller by pulling gently (Ex.6).
    Aquascape-45066-SLD-Pond-Pump- \(8\)

  • Clean with a sponge or soft-bristled brush and Aquascape Pump Cleaner Maintenance Solution (#91143) to keep your pump operating properly and maximize its lifespan.

  • Re-install the impeller, making sure the gasket is in place and the raised key on the impeller flange is aligned with the matching notch in the face of the pump flange (Ex. 7 & Ex. 8). Aquascape-45066-SLD-Pond-Pump- \(9\)

Troubleshooting

  • Reduced water flow
    • Follow maintenance procedures to clean the pump intake and water chamber cover
  • Pump hums but doesn’t push water
    • The pump or plumbing may be clogged
    • Make sure nothing is blocking the intake
    • Follow maintenance procedures to clean the intake and water chamber cover
    • Follow maintenance procedures to clean the impeller and internal pump body
    • Make sure the pump is receiving the correct voltage
    • Make sure the impeller blades are not worn or damaged
  • Pump not working
    • Verify the pump is plugged in and the outlet is on
    • Ground fault circuit interrupter (GFCI) may have tripped
    • The pump is not receiving the correct voltage

Replacement Parts

SLD 5000, 7000 & 9000 Replacement Parts

Aquascape-45066-SLD-Pond-Pump- \(10\)

Warranty Information

3 YEAR WARRANTY
Aquascape warrants that the SLD Pond Pump will be free of manufacturing defects for three years from date of purchase. Proof of purchase required. Warranty does not cover damage resulting from electrical supply problems, improper wiring, lightning, negligent handling, misapplication, misuse, or lack of reasonable maintenance or care. Warranty does not cover parts subject to normal wear, such as impellers. This product should only be operated with constant, unrestricted access to fresh water, without corrosive chemicals like chlorine or bromine. Running the pump dry, or without sufficient water, can cause the internal components to overheat and damage the pump. If upon Aquascape’s inspection, the pump shows evidence of a manufacturing defect, Aquascape’s liability is limited, at Aquascape’s option, to the repair of the defect, replacement of the defective product, or refund of the original purchase price. The warranty excludes costs of labor, removal of product, shipping and expenses related to the installation and re-installation of the product. All products that include plumbing (tubing, pumps, check valves) need to be properly drained and winterized otherwise warranty is null and void. No liability for loss or damage of any nature or kind, whether arising out of or from the use of the product, whether defective or not defective, is assumed by Aquascape, Inc. or its affiliates. Aquascape shall not be liable for any incidental, consequential or other damages arising under any theory of law whatsoever.

For more information about our company or products, please visit our website at aquascapeinc.com or call us at US 866-877-6637 CAN 866-766-3426

45066-45067-45068 – 12/23
©2023 Aquascape, Inc. • All Worldwide Rights Reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Aquascape User Manuals