Features
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 second
- No load power consumption<0.3W
- Miniature size and 1U low profile
- High operating temperature up to 70’C
- Protections: Short circuit/ Overload/Over voltage
- Cooling by free air convection
- Compliance to IEC/BS EN/EN 60335-1(PD3) and IEC/BS EN/EN61558-1, -2-16 for household appliances
- Operating altitude up to 5000 meters (Note.7)
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- LED indicator for power on
- Over voltage category II
- 100% full load burn-in test
- 3 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipment’s or apparatus
- Household appliances
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
LRS-75 series is a 75W single-output enclosed type power supply with 30mm of
love profile design. Adopting the full range 85-264VAC input, the entire
series provides an output voltage line of 5V, 12V, 15V, 24V, 36V and 48V.
In addition to the high efficiency up to 91.5%, the design of metallic mesh
case enhances the heat dissipation of LRS-75 that the whole series operates
from -30C through 70C under air convection without a fan. Delivering an
extremely low no load power consumption (less than 0.3W), it allows the end
system to easily meet the worldwide energy requirement. LRS-75 has the
complete protection functions and 5G anti- vibration capability; it is
complied with the international safety regulations such as TUV BS
EN/EN62368-1, BS EN/EN60335-1,BS EN/EN61558-1/-2-16, UL62368-1 and GB4943.
LRS-75 series serves as a high price-to-performance power supply solution for
various industrial applications.
Model Encoding
SPECIFICATION
NOTE
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- Tolerance: includes set up tolerance, line regulation and load regulation.
- Line regulation is measured from low line to high line at rated load.
- Load regulation is measured from 0% to 100% rated load.
- Length of set up time is measured at cold first start. Turning ONOFF the power supply very quickly may lead to increase of the set up time.
- The ambient temperature derating of 5C/1000m is needed for operating altitude greater than 2000m(6500ft).
- The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by
NOTE mounting the unit on a 360mm 360Omm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. (as available on http://www.meanwell.com)
Product Liability Disclaimer : For detailed information. please refer to https:/www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>