Westinghouse WH22 Saynet EI Valeria Fan Saint Lact Owner’s Manual
- May 15, 2024
- Westinghouse
Table of Contents
- Westinghouse WH22 Saynet EI Valeria Fan Saint Lact
- Product Usage Instructions
- FAQ
- SAFETY TIPS
- TOOLS REQUIRED
- PREPARING FOR INSTALLATION
- MOUNTING BRACKET INSTALLATION ****
- WIRING OPTIONS
- DOWNROD MOUNT
- SECURE TO CEILING
- BLADES INSTALLATION
- LIGHT FIXTURE INSTALLATION
- REMOTE CONTROL
- HOW TO OPERATE YOUR CEILING FAN
- OPERATION & MAINTENANCE
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Westinghouse WH22 Saynet EI Valeria Fan Saint Lact
Specifications
- Model: Saynet-EI-Valeria-WH22
- Usage: Indoor
- Installation Height: Minimum 2.3m from the blades to the floor
- Switch Requirement: 2-pole switch with a 3mm contact opening
- Safety Rating: IP20 (Not suitable for bathroom or damp areas)
Product Usage Instructions
Safety Tips:
- Read all instructions before starting the installation.
- Use only with a 2-pole switch with specific contact opening.
- Installation should be done by an authorized electrician.
- Maintain a minimum distance of 2.3m between the fan blades and the floor.
- Avoid placing inflammable materials near the lamp as indicated.
- Securely fasten the fan to the ceiling.
- Avoid using a dimmer switch to control fan speed.
- Ensure blades are not bent and no objects are in the rotation area to prevent injuries.
- Avoid using the fan simultaneously with gas or fuel-burning fires without proper testing.
- Supervise children and individuals with limited capabilities when using the appliance.
- Only suitable for indoor use.
- Disconnect the power supply before disassembling or replacing light bulbs.
- Avoid removing the lampshade while power supply is on.
- Replace light bulb only when the light kit is cooled down and power supply is disconnected.
- Ensure lampshade is in fixed position during operation.
- Incorporate means for full disconnection in fixed wiring according to national rules.
Features:
DOWNROD INSTALLATION – Suitable for normal ceilings.
FAQ
- Q: Can the fan be used in damp areas like bathrooms?
- A: No, the fan is designed for indoor use only and should not be installed in damp areas like bathrooms.
- Q: Is it necessary to use a specific type of switch with this fan?
- A: Yes, the fan should only be operated with a 2-pole switch having a 3mm contact opening for safety reasons.
SAFETY TIPS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING
- Proceed with caution. Read all instructions before beginning the installation.
- WARNING! This fan may be operated only with a 2-pole switch with a 3mm contact opening each.
- Only an authorized electrician should execute the installation.
- The installation height, i.e. the distance between the blades and the floor, should be at least 2.3 m.
- Always maintain the distance between the lamp and inflammable materials (curtains, wall, etc.), as indicated on the pictogram.
- Make sure the fan is securely fastened at the ceiling.
- WARNING! Do not use a dimmer-type switch to control the fan speed.
- WARNING! To prevent injuries, make sure the blades are not bent and that there are no objects with in the area of rotation.
- WARNING: Do Not use this fan in the same room at the same time as a gas or fuel-burning fire, unless the flue has been tested under these conditions of use by a competent person.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- Suitable for use indoors.
- Before disassembling light kit, make sure the power supply is disconnected from the main supply. Power supply can be on only after installation is completed.
- The lampshade should not be removed from the light bulb when the power supply is on.
- Replacement of the light bulb is only possible when the light kit has cooled down, and the power supply is disconnected from the main supply.
- Make sure the lampshade is in a fixed position when operating the product.
- This means that all pole disconnections having a contact separation that provides full disconnection under over-voltage category III conditions must be incorporated in the fixed wiring in accordance with national wiring rules.
- IP20 The fan is designed for indoor use. It is not designed for installation in a bathroom or any damp area. Please ensure that the lamp does not come into contact with water.
TOOLS REQUIRED
- Phillips Screwdriver
- Wire Cutters
- Pliers
- Step Ladder
FEATURES
PREPARING FOR INSTALLATION
Unpack and inspect fan carefully to be certain all contents are included. Turn off power at fuse box to avoid possible electrical shock.
MOUNTING BRACKET INSTALLATION ****
Remove the screws and star washers from the two mating holes (1) on the canopy. Loosen (do not remove) the screws in the mating slots (2) on the canopy. Rotate the mounting bracket and remove from the canopy.
Note: This step is for Solid Wood construction ceiling installation, for concrete ceiling installation, skip to step 4.
Drill two mounting holes in the ceiling joist and securely screw the mounting bracket to the ceiling using the washers and wood screws provided. The mounting plate should be able to hold a weight of at least 15.9kgs (35 lbs). NOTE – Proper care must be taken when mounting to concrete ceilings. For safe mounting, these ceilings may require stronger screws and plastic plugs or anchors than supplied with the product.
Note: Proper care must be taken when mounting to concrete ceilings and add the expansion anchors installation step for mounting bracket.
Drill one hole on each side of the supply mains for the expansion anchors. Measure this distance using the oval slots in the mounting bracket (1) as a guide
Drive the expansion anchors (1) into the holes. (Note: do not detach hex nut (2), spring washer (3) and metal washer (4) for this step).
Tighten hex nut until feel the metal expansion anchor is not working loose.
Remove the hex nut, spring washer, metal washer, keep them for next step usage.
Pull the supply mains (1) through the center of the ceiling, and align the two oval holes in the mounting bracket with the expansion anchors (1), re-install metal washer, spring washer and hex nut, tighten the hex nut until the mounting bracket is fix stably.
Repeat for another one of the expansion anchors.
WIRING OPTIONS
DOWNROD MOUNT
Remove clamp pin (2) and cross pin (1) from down rod. Loosen set screw in down rod ball (3) until ball moves easily up and down the down rod. Slide down rod ball off the down rod, exposing cross pin (4). Remove cross pin and save for later use.
Insert the downrod through the canopy and coupling cover. Carefully thread lead wires and plug though the downrod and ball assembly. Note: Avoid damaging the wire and plug, and smoothly assemble the lead wire, separately push the connector with light wire, motor wire and ground wire through the down rod for assembling
Re-install cross pin into downrod and slide downrod ball up until cross pin fits firmly into ball. Tighten set screw in ball
Loose (but do not remove) the set screws from the down rod coupling. Insert downrod (1) into downrod coupling (2). Make sure to align hole in downrod with the hole in downrod coupling. Install cross pin (3) through coupling and downrod. Insert clamp pin (4) into cross pin until it snaps into place. Tighten set screws (5) in coupling. Slide coupling cover (6) over the downrod coupling
Carefully lift fan assembly onto mounting bracket. Rotate fan until notch on downrod ball (1) engages the ridge (2) on the mounting bracket. This will allow for hands free wiring.
After hanging fan onto the mounting bracket, make sure plug connectors from the ceiling fan and terminal block (1) are moved away from the space located above the downrod ball (2). Slide the remote receiver into the space above the downrod ball as shown
While fan is hanging on bracket, plug 3-pole & 2-pole male connector from the fan into the 3-pole & 2-pole female connector from the remote receiver (1). Plug the 3-pole female connector from the terminal block into the 3-pole male connector from the receiver (2). Attach the ground wire single pin (3) together from the down rod ball to the mounting bracket.
SECURE TO CEILING
The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy, allowing the two screws to slide into the mating slots. Rotate the canopy until both screws from the mounting bracket drop into the slot recesses. Tighten screws securely. Install two screws and star washers into the mating holes of the canopy and tighten to secure the canopy to the mounting bracket
BLADES INSTALLATION
If plastic shipping stabilizer tabs are attached to motor, remove and discard. Attach blade assembly to motor using the motor screws, spring washers and flat washers provided. Tighten screws securely. NOTE: Some models do not utilize motor gaskets, washers, or stabilizer tabs.
LIGHT FIXTURE INSTALLATION
Remove one of the screws on the switch housing plate (1), and loosen, (do not remove) the other three (2).
Insert the wires with plug from the fan through the middle hole in the metal decorative shade (1). Position three slots on the metal decorative shade directly under and in line with the three screws in the switch housing mounting plate. Lift the metal decorative shade, allowing the three screws to slide into the mating slots. Rotate the metal decorative shade until three screws from the switch housing mounting plate drop into the slot recesses. Install the screw removed in step 20 into the closed hole of the metal decorative shade and tighten all 4 screws securely
Remove the 3 screws on the metal decorative shade (1). Find the wire plugs from the light kit and from the motor and slide them together
The light kit (1) has 3 closed holes, align the holes on the light kit to the screw holes from the metal decorative shade. Raise the light kit to the metal decorative shade and tighten three screws removed on last step to secure the light kit.
Locate the indentations on the neck of the glass (2) and align with the protrusions from the light kit (1). Lift the glass up allowing the protrusions to engage the indentations on the glass, and twist the glass clockwise to lock into place.
REMOTE CONTROL
Mount the transmitter holder onto the wall using screws provided. Place the transmitter into the holder
HOW TO OPERATE YOUR CEILING FAN
Restore electrical power to the outlet box by turning the electricity on at
the main fuse box. To make the fan operational,
install 2 AAA 1.5V batteries by removing the battery cover on back of the
transmitter, installing the battery, and replacing the battery cover.
- Adopt RF wireless digit emission technique, biunique controlled, coincident code rate is less than one millionth.
- The receiver can be controlled by any angles of the transmitter in prescriptive space, unrestricted by direction with the memory function, the controller can save the status (light and direction) while the supply power OFF and resume to the original after re-load the power supply.
- The transmitter and receiver are matched at the factory. Please follow point 5 for a re-match when the match is failed.
- The matching process can be done by fan without the blades, the same transmitter can control another identical model ceiling fan.
- Learning code matching mode is used between transmitter and receiver. Turn ’ on’ the supply power within 30 seconds and press the transmitter’s fan switch button ‘ ‘ for 5 seconds, it can load normally after hearing a long sound ‘bee’, which means learning successfully and it can works normally.
- Learning mode is not accepted after turn ‘ON’ the supply power for 30 seconds.
- When the transmitter can’t control the receiver, please check the battery switch touching normally or not, correct the positive and negative, full or empty of the power.
- When the transmitter can’t control the receiver, please check if any similar remote control is controlling the products nearly, then check whether they are working, because remote-controlled products with the same frequency will disturb each other.
- Low voltage of battery will affect the sensitivity of the transmitter and the signal reception accordingly, (the indicated light will flash out its warning when the battery with the low voltage), and must replace if the battery is getting low voltage.
- Please take out the battery from the transmitter when left unused for long time.
- The maximum load of lighting will be 140W. Please connect the ground wire correctly, otherwise, it may cause the light micro-light or flash.
- When installing the fan, the fan ceiling cover don’t press the antenna (or other wire), it is easy to break down the wire and short-circuit.
Remote Control Operation
-
Reversible switch- press and release the button controls direction, forward or reverse.
-
Fan switch– press and release the button, the remote turns fan off.
-
Speed switch-press and release the button. The remote operates the fan speed as follows:
- 1-lowest fan speed,2-Med low fan speed,
- 3-Low fan speed;
- 4-Med fan speed;
- 5-Med high fan speed; 6-Highest fan speed.
-
Timing control of the fan.
-
Light switch-Short press and release the button, the remote turns light ON.
-
Light switch-Short press and release the button, the remote turns light OFF.
Note: Quickly turn Light ON/OFF, it will change Color Temperature. -
Light dimmer’+’, continuous pressure on the light button dims light from dark to light.
-
Light dimmer ‘-’, continuous pressure on the light button dims light from light to dark.
-
LED indicated light. Pressed the button, the LED lighting
OPERATION & MAINTENANCE
Operation
- Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls direction, forward or reverse.
- Warm weather/down position – (Forward) Fan turns counterclockwise direction. A downward air flow creates a cooling effect as shown in illustration A.
- This allows you to set your air conditioner on a higher temperature setting without affecting your comfort.
- Cool-weather/up position – (Reverse) Fan turns clockwise direction. An upward airflow moves warm air off the ceiling area as shown in illustration B. This allows you to set your heating unit on a lower setting without affecting your comfort.
- NOTE: Turn off and wait for fan to stop before changing the setting of the forward/reverse slide switch.
Maintenance
- Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure.
- Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning. This could damage the motor, or the wood, or possibly cause electrical shock.
- Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer coating to minimize discolouration or tarnishing.
- There is no need to oil your fan. The motor has permanently lubricated bearings.
TROUBLESHOOTING
Meaning of crossed-out wheeled dustbin:
- Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.
- Contact you local government for information regarding the collection systems available.
- If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.
- When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least free of charge.
Westinghouse Lighting,
- Philadelphia, PA 19154-1029, U.S.A.
- www.westinghouselighting.com
References