- Eberle UTE 3500 UTE Universal Thermostat Inserts
- Specifications
- Area of use
- Installation site
- Electrical connection
- Dimensions
- Components
- Circuit diagram
- Technical Data
- Operation in normal use
- Installer Menu
- Error indication
- Matter WiFi Configuration
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Eberle UTE 3500 UTE Universal Thermostat Inserts
Specifications
- Model: UTE 3500, UTE 3800-U
- Power Supply: Variable
- Temperature Setting Range: 5 min / 60 min
- Connectivity: Programmable
- Programmable Switching Times: 5 min / 60 min
Important
- The device may only be opened by an electrically skilled person and must be installed as shown on the circuit diagram on the device and in these instructions. The existing safety regulations must be followed.
- The relevant installation measures must be taken to achieve the requirements of protection class II.
- This independently mountable electronic device is used to control the temperature in dry and enclosed rooms only, with a normal environment. This device conforms to EN 60730, it operates according to type 1Y (UTE 3500) and 1B (UTE 3800U).
Area of use
The electronic temperature controllers UTE 3500 and UTE 3800U can be used to control the floor and room temperature. They are suitable for waterbased and electric heating systems.
Installation site
- The controller should be mounted in a place in the room that is easy to access for operation.
- Mounting height: approx. 1.5 m above the floor.
- Preference should be given to installation on an internal wall. Avoid external walls and draughts from windows and doors.
- Ensure that the room’s normal convection air reaches the controller freely without restriction. The controller should therefore not be mounted inside shelf units or behind curtains and similar coverings.
- Extraneous heat has a negative influence on the control accuracy.
- Direct sunshine, and proximity to televisions, radios and heaters, lamps, stoves, and heating pipes must be avoided.
- Install in flush-mounting box 60mm
Electrical connection
Important: Disconnect the electric circuit from the mains
Connection in the following steps:
- Connect the power module according to the circuit diagram (see bottom of housing or circuit diagram in these instructions.)
- Note the mounting direction of the power module in the box (arrow pointing upwards)
- Mount the cover frame
- Fixate the cover frame with the decorative frame holder
- Insert the logic module
Attention: Only mount in non-conducting (plastic) flash-mounting boxes only.
Dimensions
Components
Circuit diagram
Abbreviations in the circuit diagram
- = Outer conductor (phase)
- = Neutral conductor (previously Mp)
- = Universal input (Setback/Presence)
- = Heating load connection
- = Cooling load connection
- = Heating/Cooling Change-over Input
UTE 3500
Attention: Risk of fatal injury, due to electric shock. The appliance is not a safety extra-low voltage device (SELV). The sensor cables are connected to 230 V AC mains voltage. Only use sensors with insulated cables. Failure to do so may result in serious injury or death.
UTE 3800-U
Attention: Risk of fatal injury, due to electric shock. Theappliance is not a safety extra-low voltage device (SELV). The sensor cables are connected to 230 V AC mains voltage. Only use sensors with insulated cables. Failure to do so may result in serious injury or death.
Status-LED
- red: Active Heating
- blue: Active Cooling
- green: Unoccupied Mode green
- flashing: Window open detection
- white: Matter WiFi Connection
- yellow: WiFi Connection Error
Note: The heating and cooling LED shows the difference to the setpoint, not the switching status of the output
Technical Data
Use case (depending on variant)
Selection after the first start
- P2: Hydronic Underfloor Heating – Room or inside the menu:
- P3: Hydronic Radiator – Room
- P4: Blow convector – Room (Attention: Use UTE 3500 only with external relay)
- P5: Electrical Radiator, Infrared – Room (Attention: Use UTE 3500 only with external relay)
- P6: Hydronic Underfloor Heating – Limiter
- P7: Electrical Underfloor heating – Floor Confirm the selection with [O]-Button.
- P8: Electrical Underfloor Heating – Limiter
Actuators NC / NO (only UTE 3500)
Via the installer menu, it can be adjusted whether the thermostat controls the
actuators normally closed (NC; default) or normally open (NO)
Universal input: setback input/presence sensor.
The function of the universal input can be adjusted in the Installer Menu
(default: setback input). When the setback input is energized, the controller
switches to unoccupied mode. When the presence sensor input is energized, the
controller switches to occupied mode.
SETPOINT
Heating / Cooling input
H/C-terminal connected to voltage means cooling mode, not connected means
heating mode. In case of cable used longer than 100m an anti-interference
capacitor (Capacitor 230 VAC 0,33µF or comparable) between control line H/C
and neutral line N can be installed at any position to avoid a malfunction.
Operation in normal use
Installer Menu
- Press and hold [+] and [O] buttons simultaneously for 5 seconds. The WiFi LED lights up purple.
- Browse through the menu items by pressing the [O] or [+] buttons.
- Confirm your selection by pressing the [O] button.
- To exit the menu without saving: Press and hold the [+] and [O] buttons or wait for 10 sec.
Installer Menu (Level 1): Selection of presets
Depending on the specific use case, preset values and functions can be adopted
at level 1.
Enter code: 19. The WiFi-LED lights up purple
Overview of preset values of each use case
Adjustable at Installer Menu (level 2)
Installer Menu (Level 2):
For advanced settings of individual menu items after confirming the Installer
menu (level 1) preset:
Enter code: 32
Error indication
In the event of sensor errors, the controller detects which sensor is faulty:
- E1 = room sensor error
- E2 = floor probe error
This product should not be disposed of with household waste. Please recycle the products where facilities for electronic waste exist. Check with your local authorities for recycling advice.
Matter WiFi Configuration
How-to Video:
- Via Matter, the thermostat can be connected to smart home apps and the respective controllers/hubs from Apple, Google, Amazon, and Samsung.
- To integrate the thermostat into a Smart Home App and the respective Matter WiFi network, scan the QR code on the back of the logic module with a smartphone or type in the eleven-digit Matter provisioning code.
Press the [O] button for 5 seconds until the thermostat displays „Jn“ for Join Mode. The WiFi LED lights up yellow
If an error occurs during connection, the controller displays „Er“ for Error: The WiFi LED lights up red.
Acknowledge with [O] and restart the Matter WiFi configuration.
User Menu
- To access the user menu, press and hold the [-] and [O] buttons simultaneously for 3 seconds. The WiFi LED lights up yellow.
- Browse through the menu items by pressing the [+] or [-] buttons.
- Confirm your selection by pressing the [O] button.
- To exit the menu without saving: Press the [-] and [O] buttons or wait for 10 sec
The following settings can be adjusted
This product should not be disposed of with household waste. Please recycle the products where facilities for electronic waste exist. Check with your local authorities for recycling advice.
FAQ
Frequently Asked Questions
- 1. How to reset the device?
- To reset the device, press [O] and restart the setup process.
- 2. How to adjust the brightness of the LEDs?
- In the standby mode, you can adjust the brightness of the LEDs from 0% to 100%.
- 3. How to activate the child lock?
- To activate the child lock, navigate to the settings and select the lock option.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>