MEAN WELL LRS-100-3-3 100W Single Output Switching Power Supply Instructions

June 4, 2024
MEAN WELL

MEAN-WELL-logo

MEAN WELL LRS-100-3-3 100W Single Output Switching Power Supply

MEAN-WELL-LRS-100-3-3-100W-Single-Output-Switching-Power-Supply-
product

Features

  • Universal AC input/ Full range
  • Withstand 300VAC surge input for 5 second
  • Protections: Short circuit/ Overload/Over voltage
  • Cooling by free air convection
  • Miniature size and 1U low profile
  • Compliance to IEC/BS EN/EN 60335-1(PD3) and
  • IEC/BS EN/EN61558-1,2-16 for household appliances
  • Operating altitude up to 5000 meters (Note.7)
  • Withstand 5G vibration test
  • LED indicator for power on
  • No load power consumption<0.3W
  • Overvoltage category 11
  • 100% full load burn-in test
  • High operating temperature up to 70’C
  • High efficiency, long life, and high reliability
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipment or apparatus
  • Household appliances

Description

LRS-100 series is a 100W single-output enclosed type power supply with 30mm of low profile design. Adopting the full range 85-264VAC input, the entire series provides an output voltage line of 3.3V, 5V, 12V, 15V, 24V, 36V and 48V.

In addition to the high efficiency up to 91%, the design of the metallic mesh case enhances the heat dissipation of LRS-100 and the whole series operates from -30’C through 70’C under air convection without a fan. Delivering an extremely low no-load power consumption (less than 0.3W), it allows the end system to easily meet the worldwide energy requirement. LRS-100 has complete protection functions and 5G anti-vibration capability; it complies with international safety regulations such as TUV BS EN/EN2368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, UL62368-1, and GB4943. LRS-100 series serves as a high- price-to-performance power supply solution for various industrial applications.

Model Encoding SPECIFICATION

MODEL| LRS-100-3.3| LRS-100-5| LRS-100-12| LRS-100-15| LRS-100-24| LRS-100-36| LRS-100-48
---|---|---|---|---|---|---|---






OUTPUT

| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 36V| 48V
RATED CURRENT| 20A| 18A| 8.5A| 7A| 4.5A| 2.8A| 2.3A
CURRENT RANGE| 0 ~ 20A| 0 ~ 18A| 0 ~ 8.5A| 0 ~ 7A| 0 ~ 4.5A| 0 ~ 2.8A| 0 ~ 2.3A
RATED POWER| 66W| 90W| 102W| 105W| 108W| 100.8W| 110.4W
RIPPLE & NOISE (max.) Note.2| 100mVp-p| 100mVp-p| 120mVp-p| 120mVp-p| 150mVp-p| 200mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 2.97 ~ 3.6V| 4.5 ~ 5.5V| 10.2 ~ 13.8V| 13.5 ~ 18V| 21.6 ~ 28.8V| 32.4 ~ 39.6V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION Note.4| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION Note.5| ±2.0%| ±1.0%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 500ms, 30ms/230VAC        500ms,30ms/115VAC at full load
HOLD UP TIME (Typ.)| 55ms/230VAC      10ms/115VAC at full load



INPUT

| VOLTAGE RANGE| 85 ~ 264VAC         120 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 84.5%| 86%| 88%| 88.5%| 90%| 90.5%| 91%
AC CURRENT (Typ.)| 1.9A/115VAC         1.2A/230VAC
INRUSH CURRENT (Typ.)| COLD START 50A/230VAC
LEAKAGE CURRENT| <0.75mA / 240VAC



PROTECTION

| OVER LOAD| 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 18.75 ~ 21.75V| 28.8 ~ 33.6V| 41.4 ~ 48.6V| 55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover



ENVIRONMENT

| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OVER VOLTAGE CATEGORY| Ⅲ; Compliance to BS EN/EN61558, BS EN/EN50178, BS EN/EN60664-1, BS EN/EN62477-1; altitude up to 2000 meters




SAFETY & EMC

(Note 8)

| ****

SAFETY STANDARDS

| UL 62368-1, TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16,CCC GB4943.1,BSMI CNS14336-1, EAC TP TC 004,S/NZS62368.1(by CB),KC K60950-1(for LRS-100-12/24 only), BIS IS13252(Part1):

2010/IEC 60950-1: 2005 approved

WITHSTAND VOLTAGE| I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.25KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN55014, BS EN/EN61000-3-2,-3, GB/T 9254, BSMI CNS13438, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020,KC KN32,KN35(for LRS-100-12/24 only)


OTHERS

| MTBF| 720.6K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION| 1299730mm (LWH)
PACKING| 0.34Kg ; 40pcs/14.6Kg/0.92CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25C of ambient temperature.

  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

  3. Tolerance: includes set up tolerance, line regulation and load regulation.

  4. Line regulation is measured from low line to high line at the rated load.

  5. Load regulation is measured from 0% to 100% rated load.

  6. Length of set up time is measured at cold first start. Turning ONOFF the power supply very quickly may lead to an increase of the set up
    time.

  7. The ambient temperature derating of 5C/1000m is needed for an operating altitude greater than 2000m(6500ft).

  8. The power supply is considered a component that will be installed into the final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets
    EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.
    (as available on http://www.meanwell.com.

Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN-WELL-LRS-100-3-3-100W-Single-Output-Switching-Power-Supply-
fig-2

Derating Curve

MEAN-WELL-LRS-100-3-3-100W-Single-Output-Switching-Power-Supply-
fig-3

Static Characteristics

Mechanical Specification

MEAN-WELL-LRS-100-3-3-100W-Single-Output-Switching-Power-Supply-
fig-5

Installation Manual

Please refer to: http://www.meanwell.com/manual.html.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals