Westinghouse 5247000 14 Watt 100 Watt Equivalent 5 6 Inch Square Recessed LED Downlight Instruction Manual

June 17, 2024
Westinghouse

Westinghouse 5247000 14 Watt 100 Watt Equivalent 5 6 Inch Square Recessed

LED Downlight

Westinghouse-5247000-14-Watt-100-Watt-Equivalent-5-6-Inch-Square-Recessed-
LED-Downlight-product

Product Information

Specifications:

  • Model: W-787 032823
  • Type: LED Retrofit Trim
  • Compatibility: Suitable for Type IC or Non-IC luminaires
  • Installation: Suitable for wet locations

Product Usage Instructions

Parts Included:

  • LED retrofit luminaire conversion kit
  • Installation instructions
  • LED lamp
  • Field-applied label

Installation Steps:

  1. Turn off power at the circuit box to avoid electric shock.
  2. Thread the SOCKET ADAPTER into the SOCKET.
  3. Use the toggle switch to select your desired lamp color temperature.
  4. Choose between 5” or 6” installation based on the size of the recessed fixture and adjust the springs/clips accordingly.
  5. For the torsion spring option, squeeze both TORSION SPRING arms together and insert into the TORSION SPRING.

Safety Warnings:

  • Disconnect the main power at fuse or circuit breaker before installing or servicing the fixture.
  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Avoid exposing wiring to edges of sharp objects to prevent damage or abrasion.
  • Product must be installed by a qualified electrician in accordance with applicable electrical codes.

Additional Notes:

This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.

Frequently Asked Questions

Q: Can I install this retrofit trim in emergency exits?

A: No, this trim is not intended for use with emergency exits.

Q: What lamp color temperature options are available?

A: You can choose from Soft White (2700K), Warm White (3000K), Bright White (3500K), Cool White (4000K), or Daylight (5000K).

Q: What should I do if I am not qualified to install the LED retrofit kit?

A: Contact a qualified electrician for installation to prevent any risks of fire or electric shock.

Please read carefully and save these instructions, as you may need them at a later date.
GENERAL: All electrical connections must be in accordance with local and National Electrical  Code (N.E.C.) standards. If you are unfamiliar with proper electrical wiring connections obtain the services of a qualified electrician. Remove the trim from the box and make sure that no parts are missing by referencing the parts illustrations. The LED retrofit luminaire conversion kit includes installation instructions, LED lamp and a field- applied label. SUITABLE FOR TYPE IC OR NON-IC LUMINAIRES INSTALL THIS TRIM IN RECESSED HOUSINGS THAT HAVE DIMENSIONS SHOWN IN FIG. 1. THIS DEVICE IS NOT INTENDED FOR USE WITH EMERGENCY EXITS.SUITABLE FOR WET LOCATIONS. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN INACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS. FOR RETROFIT KITS CERTIFIED TO CANADIAN REQUIREMENTS.
WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

ASSEMBLY AND INSTALLATION

INCANDESCENT HOUSINGS

  1. Turn off power at circuit box to avoid possible electric shock.

  2. Thread the SOCKET ADAPTER into the SOCKET (FIG. 2).

  3. Use the toggle switch to select your desired lamp color temperature – Soft White (2700K), Warm White (3000K), Bright White (3500K), Cool White (4000K) or Daylight (5000K) (FIG. 3).

  4. According to the size of recessed fixture to choose 5” or 6” installation,slide the springs/clips to the position which marks 5” or 6” (Refer to Fig 5a, 6a, 7a & 8a).

    • For the torsion spring option, please follow below steps.

    • Squeeze both TORSION SPRING arms together and insert into the TORSION SPRING SLOTS (or RECEIVER BRACKETS) of the recessed housing. Tuck all wires into the recessed housing, carefully push the RETROFIT TRIM into recessed housing, then adjust the horizontal angle as requirement. (NOTE: To provide enough room in shallow cans, carefully position SOCKET ADAPTER and SOCKET adjacent to the long side of the LED DRIVER prior to inserting the RETROFIT TRIM into the recessed housing.) (FIG. 4a)
      Note: For 5″ installation, slide the springs to the position which marks 5″. (Refer to Fig 5a, 6a, 7a & 8a)

    • For the clip option, please remove torsion spring and replace with clips.

    • Squeeze both clip arms together and insert into the clip of the recessed housing. Tuck all wires into the recessed housing, carefully push the RETROFIT TRIM into recessed housing, then adjust the horizontal angle as required. (NOTE: To provide enough room in shallow recessed housing, carefully position SOCKET ADAPTER and SOCKET adjacent to the long side of the LED DRIVER prior to inserting the RETROFIT TRIM into the recessed housing.) (FIG. 4b)
      Note: For 5″ installation, slide the clips to the position which marks 5″. (Refer to Fig 5b, 6b, 7b, 8b & 9b)Westinghouse-5247000-14-Watt-100-Watt-
Equivalent-5-6-Inch-Square-Recessed-LED-Downlight-fig-1 Westinghouse-5247000-14-Watt-100-Watt-Equivalent-5-6-Inch-Square-Recessed-
LED-Downlight-fig-2

DIMMING

Although this product is compatible with most common residential-type dimmers, dimming performance depends on a dimmer, dimmer setting (for dimmers with brightness range adjustments), wiring method, and the number of LED modules. For best results, set the dimmer position at maximum before adjusting to a lower light level. Recommended Dimmers (minimum load for four LED modules may be required for optimal dimming performance): Levtion:6674-10W, IPL06-10Z, RDL06-10Z, R50-1PL06-10M. Lutron: DVCL-150PR-WH, CTCL-150PDH-WH, TGCL-153PH- WH, MACL-153MH-WH.

LIMITED WARRANTY

This lamp is warranted to be free from defects in materials and workmanship for 5 years. If the product fails during the warranty period, return the defective product to the seller. Warranty terms and conditions of the seller apply. If the replacement product is not available through the seller, please contact www.westinghouselighting.com/contact- us.

WARNING – RISK OF ELECTRIC SHOCK. DISCONNECT THE MAIN POWER AT THE FUSE OR CIRCUIT BREAKER BEFORE INSTALLING OR SERVICING THE FIXTURE.

Westinghouse Lighting, Philadelphia, PA 19154-1029, U.S.A.

and Westinghouse are trademarks of Westinghouse Electric Corporation. Used under license by Westinghouse Lighting. All Rights Reserved. Made in China

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals