SUB-ZERO ICBCL3650R Classic Stainless Flush User Guide

June 17, 2024
SUB-ZERO

SUB-ZERO ICBCL3650R Classic Stainless Flush

Classic Series Models
For the Classic series refrigeration, Sub-Zero designers and engineers took a fresh look at everything, inside and out. Exterior refinements include redesigned grilles and lowerprofile hinges. Inside, new technology in food preservation makes the Classic series refrigeration nothing short of revolutionary.

SUB-ZERO ICBCL3650R Classic Stainless Flush 1

Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm

SUB-ZERO ICBCL3650R Classic Stainless Flush 2

Overall Dimensions

SUB-ZERO ICBCL3650R Classic Stainless Flush 3

Overall Dimensions

SUB-ZERO ICBCL3650R Classic Stainless Flush 4

OVER-AND-UNDER

SUB-ZERO ICBCL3650R Classic Stainless Flush 5

SIDE-BY-SIDE

SUB-ZERO ICBCL3650R Classic Stainless Flush 6

Wine StorageSUB-ZERO ICBCL3650R Classic Stainless Flush
7

Dimensions are based on the stainless steel model. For flush inset applications, add 13 mm to the door clearance dimensions.

Electrical Requirements
Installation must comply with all applicable electrical codes. International models from the factory require a 220-240 V AC, 50/60 Hz electrical supply, fused at the correct rating for the unit. If required by local or national codes, the power cord can be easily replaced using the power inlet device. The electrical supply should be easily accessible and positioned either in a cabinet above the refrigerator, a minimum of 2200mm above the floor or in adjacent cabinet. If freestanding then locate the powerpoint as per the diagram below.

  • Electrical Supply 220-240 V AC, 50/60 Hz
  • Service 10 amp
  • Receptacle 3-prong grounding-type (earthed)

Plumbing Requirements

Installation must comply with all applicable plumbing codes. For Classic Series models with an automatic ice maker, a pressure limiting valve and 5 metres of flexible 6mm pipe with fittings is included in the refrigerator carton. Connect the pressure limiting valve close to the water tap, checking the water flow is in the right direction. Ensure water connection is 1/2″ BSP male threaded outlet. Fix the 6mm water line to the wall and floor to ensure it is not compressed when the refrigerator is pushed into the cavity. The water tap should be easily accessible and positioned either in a cabinet above the refrigerator, a minimum of 2200mm above the floor, or in adjacent cabinet. The water line must not interfere with installation of the anti-tip brackets. A reverse osmosis system can be used provided there is constant water pressure of 2.4–8.3 bar supplied to the unit at all times. A copper line is not recommended for this application.

  • Water Supply Line 6.4 mm OD copper, braided
  • stainless steel, or PEX tubing
  • Water Pressure 2.4–8.3 bar
  • Excess Line for Connection .9 m

SUB-ZERO ICBCL3650R Classic Stainless Flush 8

Stainless Flush Inset Application
It is necessary to consider the following points when planning for a fl ush inset application:

  • The flush inset depth is 56 mm deeper than the standard opening depth.
  • The flush inset width is 46 mm wider than the standard opening width.
  • The flush inset height is 22 mm higher than the standard opening height.
  • Must allow a 15 mm reveal around the perimeter of the unit and grille to allow for proper door swing and airfl ow.
    IMPORTANT NOTE : The fl ush inset application is not a separate model. The same model is used in a standard or flush inset application of stainless steel fridge

SUB-ZERO ICBCL3650R Classic Stainless Flush 9

Stainless Flush Inset Application

SUB-ZERO ICBCL3650R Classic Stainless Flush 10

Flush Inset Opening Widths A B
ICBCL3050W 749 mm 795 mm

ICBCL3650R, ICBCL3650F

ICBCL3650U, ICBCL3650UFD

| 902 mm| 948 mm
ICBCL4250S(ID), IBCL4250UFD| 1054 mm| 1100 mm
ICBCL4850S(ID), ICBCL4850SD ICBCL4850UFD| 1206 mm| 1252 mm

Dual Installation

STAINLESS FLUSH INSET APPLICATION
Installing two built-in models side by side in a stainless fl ush inset application will require adjustments to the dimensions of your fi nished rough opening. It will also require a dual installation kit, avail able through your authorized Sub-Zero dealer. Dual installations without a filler strip can only be accomplished using two units with opposite hinges as shown in illustration A below and dual installation kit. The dual installations shown in illustrations B and C require a 50mm wide fil ler strip. Illustration A is the only application that will accommodate the dual wide grille as part of the dual installation kit.SUB-ZERO ICBCL3650R Classic Stainless Flush
11

STAINLESS FLUSH INSET INSTALLATION – WITH ACCESSORY DUAL INSTALLATION KIT

SUB-ZERO ICBCL3650R Classic Stainless Flush 12

Opening Widths A B
Two 762 mm Models 1518 mm 1564 mm
762 mm and 914 mm Models 1670 mm 1716 mm
Two 914 mm Models 1822 mm 1868 mm

French Door models can not be dual installed.

SUB-ZERO ICBCL3650R Classic Stainless Flush 13

Warranty

b-Zero International Limited Warranty

FOR RESIDENTIAL USE
These Warranty Terms and Conditions (‘Warranty’) constitute your agreement with Sub-Zero Group Australia Pty Ltd (ACN 610 807 899) (‘Sub-Zero’) and will apply to your service order. The benefits given by this Warranty are in addition to all consumer guarantees and other rights and remedies prescribed by the Australian Consumer Law and any other applicable laws. Our products come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

In addition to your rights and remedies under the Australian Consumer Law, Sub-Zero provides customers with a Warranty where, if any part of a Sub-Zero Product is found upon inspection by an authorised Sub-Zero representative or an associated licensed technician supplied by either Sub-Zero or a relevant approved supplier (including a Sub-Zero factory certified service) (‘Service Representative’) to be defective in materials or workmanship, Sub-Zero will repair or replace the part free of charge as follows:

*FULL TWO YEAR WARRANTY (Outdoor product full one year warranty)
For two years from the date of original installation, this Sub-Zero product warranty covers all parts and labour to repair or replace, under normal residential use, any part of the product that proves to be defective in materials or workmanship. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Where the Service Representative is unable to identify any fault in the product, Sub-Zero may require the consumer to provide proof that the product is defective. For the avoidance of doubt, defective products or parts become Sub-Zero’s property. Service will be provided during normal business hours.

**FULL FIVE YEAR SEALED SYSTEM WARRANTY***
For five years from the date of original installation, this Sub-Zero product warranty covers all parts and labour to repair or replace, under normal residential use, these parts that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier and all connecting tubing. All service provided by Sub-Zero under the above warranty must be performed by Sub-Zero factory certified service, unless otherwise specified by Sub-Zero, Inc. Where the Service Representative is unable to identify any fault in the product, Sub-Zero may require the consumer to provide proof that the product is defective. For the avoidance of doubt, defective products or parts become Sub-Zero’s property. Service will be provided during normal business hours.

**TERMS APPLICABLE TO EACH WARRANTY***
The warranty applies only to products installed for normal residential use. This warranty does not cover any parts or labour to correct any defect caused by negligence, accident or improper use, maintenance, installation, service or repair.

**CLAIM PROCEDURE***
In order to claim the Warranty, you must cease using the product when a fault arises, contact Sub-Zero or authourised Sub-Zero dealer where the product was purchased to report the issue and follow Sub-Zero’s directions regarding what to do next. Sub- Zero’s general contact details are as follows:

Sub-Zero Group Australia
11-19 Bank Place
Melbourne VIC 3000
Phone: 03 9600 2218
Email: serviceAU@subzero.com

**CLAIM PROCEDURE***
Except to the extent required by law, all consumer guarantees, representations, warranties, terms and conditions in relation to the products (whether implied or otherwise) are hereby excluded to the maximum extent permitted by law. To the fullest extent permitted by law, Sub-Zero excludes all liability for damage or injury to any person, damage to any property and any indirect consequential or other loss or damage.

  • Stainless steel (doors, panels, handles, product frames and interior surfaces) are covered by a limited 60-day parts and labour warranty for cosmetic defects.
  • Replacement water filters and air purification cartridges are not covered by the product warranty.
  • Full one year warranty applies to outdoor product. Product must be approved for outdoor use, designated by model and serial number.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals