electriQ ECOSILENT8-V2 Portable Air Conditioner
Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals
SETTLING IN OK
We hope this has been helpful to you. We would love to see how you’re getting on with your new purchase, so please share any snaps you have on the platform of your choice below. Our community awaits your uploads Snap, tag and hashtag away! WE’RE HERE TO HELP Should you have any problems or questions with your purchase, please contact a member of our customer service team.
- 0330 390 3061
- Support@electriQ.co.uk
- Mon-Fri | 9am to 5pm
Unit J6, Lowfields Business Park, Lowfields Way, Elland West Yorkshire, HX5 9DA
SAFETY INSTRUCTIONS
Important!
- Carefully read the instructions before operating the unit
- This appliance is for indoor use only.
- Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet.
- Installation must be in accordance with regulations of the country where the unit is used.
- If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
- This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
- Disconnect the power from the appliance before dismantling, assembling or cleaning.
- Avoid touching any moving parts of the appliance.
- Never insert fingers, pencils or any other objects though the guard
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Do not leave children unsupervised with this appliance.
- Do not clean the unit by spraying it or immersing it in water.
- Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
- Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
- A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
- Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty.
- Do not use the appliance for any purpose other than its intended use.
- The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
- Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
- Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF button located on the control panel.
- Always place the unit on a dry and stable surface.
- The appliance should not be installed in laundry or wet rooms.
- The appliance must be placed in a room without sources of ignition (for example: open flames, an operating gas appliance or an operating electric heater).
- R290 refrigerant gas complies with European environmental directives.
- R290 has a low GWP (Global Warming Potential) of 3.
- The ECOSILENT8 contains about 180 g of R290 refrigerant gas.
- The ECOSILENT10 contains about 240 g of R290 refrigerant gas.
- Do not use or store in an unventilated space with an area smaller than 8.7 m2 per unit (ECOSILENT8) or 11.5 m2 per unit (ECOSILENT10).
- The room must be such as to prevent stagnation of possible leaks of refrigerant gas as there could be a danger of fire or explosion should the refrigerant come into contact with electric heaters, stoves or other sources of ignition.
- Refrigerant gas may be odourless.
- Do not use the product and contact the retailer for advice, if damage has occurred to the unit which may have compromised the refrigerant system.
- Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer. Before opening and servicing the unit the authorised engineer must be in possession of a copy of the manufacturer’s service manual and must follow the safety information contained within it to ensure all hazards are minimized.
- The refrigerant system should not be perforated or punctured.
Energy Saving and Unit Safety Protection Tips
- Do not cover or restrict the airflow from the outlet or inlet grills.
- For maximum performance the minimum distance from a wall or objects should be 50cm.
- Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning maybe necessary, depending on the air quality.
- For the initial start-up set the fan speed to maximum and the thermostat to 5 degrees lower than the current room temperature. After, set appliance to your desired settings.
- To protect the unit, we recommend not using the cooling function when the ambient temperature is higher than 35oC.
FEATURES AND PARTS LIST
FEATURES
- 3 in 1 Cooling, Fan, Dehumidifier great for rooms up to 20 sqm.
- 5 speed fan: Balancing quiet operation with performance.
- 24 Hours Start / Stop Timer
- Digital Thermostat: Set the temperature between 17°C and 30°C.
- Remote Control.
- Castors and Handles for Enhanced Portability.
- Auto-Restart to retain the settings in the event of power failure.
PART LIST
INSTALLATION
WARNING : Before using this unit, please keep it upright for at least 3-4 hours.
This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface.
- Attach the fishtail connector to the end of the hose, by extending the end of the hose and twisting until firmly attached to the connector (At least 3 full rotations).
- Attach the Hose to the Outlet adaptor, in the same way by extending the end of the hose and twisting until firmly attached (At least 3 full rotations).
- Slide the Outlet adaptor into position on the rear of the unit. The two slips on the unit will hold it in place. (To remove the adaptor press the two clips down to release it from the unit)
- Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills, with at least 50cm of space to the sides and rear of the unit.
INSTALLATION OF WINDOW KIT
The window kit (slide bar and fishtail) can be used with sliding windows and
doors. For other types of window, the fishtail should be used on its own.
- Push the screw thread of the plate through the hole in the rear of the front slide bar section.
- Slide the rear section of the slide bar onto the front section lining up the plate so it runs within the groove. Extend the bar to the required length, and use the supplied wing nut to secure
- Partially open the window and place the extended slide bar in position before closing the window onto it.
- Fix the fishtail adaptor into the opening on the slide bar
NOTES:
- The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed to be used with any other style of windows.
- The fish tail adaptor can be used without the slide bar with most windows / doors.
- When using the air conditioner ensure that the opening around the fishtail adaptor is as small as possible to ensure the efficiency of the unit is not reduced.
- The best form of installation is through a wall duct. By properly venting you expel hot air from your room while efficiently cooling it.
- Your air conditioner should be used without the vent pipe in dry mode. When using dry mode ensure that an external water tank is used, monitored and regularly emptied before overflowing. Permanent plumbing can be also installed or an external uplift water pump can be set up to allow for uninterrupted use
IMPORTANT SAFEGUARDS
The length of the soft hose extends from approximately 30 cm to 180 cm. If hose is extended above this length, the unit may malfunction which can invalidate the warranty. The outlet vent must be well ventilated and not obstructed as this will cause the unit to overheat. Keep the hose as straight and short as possible and avoid bending the air hose by more than 30 degrees in order to maintain the performance of the unit. Excessive bends in the hose may prevent the unit from expelling the hot air, which can lead to internal damage which would invalidate the warranty.
OPERATION
REMOTE CONTROL
NOTE : The design of the remote may vary from the diagram, due to continuous product improvement.
MULTI PROTECTIVE FUNCTIONS
FROST PROTECTION
In COOL, DRY or AUTO modes, if the temperature of the exhaust is too low, the
machine will automatically stop operating until the temperature has risen.
OVERFLOW PROTECTION
When the water in the internal water tank exceeds the warning level, the
machine will stop operating and sound an alarm with the LCD display showing
“E4”. To resume operation empty the internal water tank. After the water is
emptied, the machine will automatically return to the original state.
AUTO-DEFROST
The machine has automatic defrosting function. If during operation the
temperature of the internal coils drops too low, the unit will enter auto
defrost and the heating symbol will flash on the control panel.
AUTOMATIC THERMAL PROTECTION
To protect the service life of the machine, the machine has automatic thermal
protection. If the temperature within the unit is outside of the specified
range, the compressor and the lower motor will stop operation. The appliance
will automatically return to normal operation after the temperature of the
machine recovers.
COMPRESSOR PROTECTION
To prevent damage to the compressor there is a 3 minute delay start protection
function.
MAINTENANCE AND CLEANING
PLEASE SHUT OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE
CLEAN THE SURFACE
Clean the surface of the machine with a wet soft cloth. Do not use chemicals,
such as benzene, alcohol, gasoline, etc; otherwise, as this may cause damage
to the surface and or the internal workings of the machine
AIR FILTER CLEANING
If the filter screen is clogged with dust, the effectiveness of the air
conditioner is reduced. The filter screen should be cleaned once every two
weeks or as often as necessarily in your environment.
CLEAN THE UPPER FILTER SCREEN FRAME
Remove the filter screen by pulling the base of it gently outwards, to unclip
it from the appliance. Once removed put the evaporator filter screen into warm
water with neutral detergent (about 40℃ /104℉) and dry it in the shade after
rinsing clean.
CLEAN THE LOWER FILTER SCREEN FRAME
Remove the filter screen by pulling the rear of it gently outwards, to unclip
it from the appliance. Put the filter screen into warm water with neutral
detergent (about 40℃ / 104 ℉) and dry it in the shade after rinsing clean
EMPTYING THE INTERNAL WATER TANK
MANUAL DRAINAGE:
When the internal water tank is full the unit will stop working, and the unit
will display E4. Turn off the unit and unplug. Try not to move the model
abruptly as this may cause the water in the internal tank to spill out. Place
a tray under the lower water plug or place the unit in a drainage area. Remove
the rubber stopper from the drain port – water will drain from the internal
tank. One the tank is empty, place the rubber stopper back in position.
CONTINUOUS DRAINAGE:
Remove the rubber stopper from the drain port on the base of the unit. Connect
a water pipe (12mm internal diameter) to the drain port. You can plumb this
pipe into your current plumbing system, lead it outside and use gravity fall
or use a water pump.
NOTE: This model has a self-evaporative function, which reduces the need to empty the water tank in cooling mode. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility
END OF SEASON MAINTENANCE
- Remove the rubber stopper from the drainage hole and empty the internal tank. You can also drain the water by leaning the unit backwards.
- Run the unit in fan mode, with a low fan speed, with the rubber stopper still removed, and a container under the drain port.
- Keep the unit in this mode for half day – until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mould from developing.
- Turn off the unit and pull out the plug.
- Replace the rubber stopper.
- Coil the wire and bind it together, then put it into the accessory space.
- Separate the vent pipe and store it safely.
- Cover the unit and keep it in a dry place.
- Take the batteries out of remote control and store or dispose of them safely. Keep all accessories with the unit ready for next season.
TROUBLESHOOTING
Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here.
Problems | Reasons | Solutions |
---|
The air conditioner does not work.
| There is no electricity.| Turn it on after connecting it to a socket with
electricity.
The display shows “E4”.| Discharge the water inside.
The ambient temperature is too low or too high| Only use to use the machine
within temperature range of 7-35⁰C (44-95⁰F).
In cooling mode, the room temperature is lower than the desired temperature|
Change the desired temperature.
In dry mode, the ambient temperature is low.| The ambient temperature must be
above 17 ⁰C. (62 ⁰F).
The cooling effect is not good
| There is direct sunlight.| Use curtains to reduce the direct sun heat
Doors or windows are open; there are a lot of people; or in cooling mode,
there
are other sources of heat (e.g. fridges)
| Close doors and windows; increase air conditioning power
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions; make sure venting is
correct as described in this user manual and hose is not bent
Loud Noise| The air conditioning is not placed on a flat surface.| Put the air
conditioning on a flat and hard place (to reduce noise).
Compressor does not work.| Overheat protection starts.| Wait for 3 minutes
until the temperature is lowered, and then restart the machine.
The remote control does not work.
| The distance between the machine and the remote control is too far.|
Let the remote control get close to the air conditioner, and make sure that the remote control directly faces the receiver.
The remote control is not aligned with the receiver.
Batteries are dead.| Replace batteries.
Others
| No refrigerant or there is very little refrigerant| Refer to Service Centre (check leakage, wielding, vacuum pump, charge refrigerant according to name plate)
Anti-freezing protection
| Waiting for defrosting.
Function will recover automatically. No user input
needed.
High pressure protection| After inside gas pressure comes down, it will function normally. No user input needed
If problems not listed in the table occur or recommended solutions do not work, please contact the service centre
ERROR CODES
CODE | CAUSE | SOLUTION |
---|---|---|
E2 | Room temperature sensor error | Check to ensure filters are clean, vent |
pipe is not restricted, and room temperature is within operational range.
E3| Air Temperature sensor Error
E4| Water Tank Full| Empty the water tank.
E5
| ****
Coil temperature sensor error
| Check to ensure filters are clean, vent pipe is not restricted, and room
temperature is within operational range.
MODE LIGHT FLASHING| Cool / dry / heating mode, the compressor has not
started, the mode light will flash. This is normal| The unit will start
operation when the protection period has finished ( approx. 3 minutes)
APPENDIX
Disposal: Do not dispose this product as unsorted municipal waste. Collection
of such waste must be handled separately as special treatment is necessary.
Recycling facilities are now available for all customers at which you can
deposit your old electrical products. Customers will be able to take any old
electrical equipment to participating civic amenity sites run by their local
councils. Please remember that this equipment will be further handled during
the recycling process, so please be considerate when depositing your
equipment. Please contact the local council for details of your local
household waste recycling centres.
electriQ UK SUPPORT
www.electriQ.co.uk/support Please, for
your own convenience, make these simple checks before calling the service
line. If the unit still fails to operate call the number below, or complete
the online form. 0330 390 3061
- Has the unit been standing upright for at least 2 hours?
- Is the unit plugged into the mains?
- Is the fuse OK?
- Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
- Check if the water tank is full
Office hours: 9AM – 5PM Monday to Friday www.electriQ.co.ukUnit J6, Lowfields Business Park Lowfields Way, Elland West Yorkshire, HX5 9DA
TECHNICAL DATA
Model | EcoSilent8-V2 | EcoSilent10-V2 |
---|---|---|
Capacity Cooling | 2350 W | 2930W |
Rated Input | 880 W | 1100W |
Running Current | 3.4 A | 4.8 A |
Fan | 5 Speeds | |
Airflow | 320m3/h | |
EER rate | A | |
Refrigerant | R290/180g | R290/240g |
Sound power level | 56dB(A) | |
Thermostat | 17-30oC |
Maximum working pressure of suction/exhaust side
| ****
1.0/3.5MPa
Maximum Allowable Pressure| 3.5Mpa
Power Supply| AC 220-240V/50Hz
Net Weight| 24kg| 24kg
Dimension(LDH)| 405315660mm
The unit must be vented outside when in Air Cooling mode. For the purposes of
EU regulation EN12102 this is a local air conditioner and produces less than
65dB(A) sound energy.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>