inim CPR-2741 Previdia Ultravox Fire Detection Control Panel Instruction Manual

June 17, 2024
INIM

CPR-2741 Previdia Ultravox Fire Detection Control Panel
Instruction Manual

CPR-2741 Previdia Ultravox Fire Detection Control Panel

CONTROL PANEL FOR FIRE DETECTION AND ALARM AND VOICE-EVACUATION SYSTEMSinim
CPR-2741 Previdia Ultravox Fire Detection Control Panel - Speaker
outputs

Technical specifications

Previdia-Ultravox

Dimensions 433 x 677 x 258 mm
Weight 23 Kg
Protection grade

FPMCPU
Power supply voltage| 19-30V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| stand-by| 130mA
maximum| 140mA
mains fault| 110mA
Maximum voltage on RS485-REPEATER| 1A @27.6V
Maximum voltage on RS485-BMS| 1A @27.6V
FPAMIAS
Power supply voltage| 20-30V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| maximum| 110mA
mains fault| 60mA
IFAMPSU
Power supply voltage| 50/60 Hz
230V~ (+10% -15%)
115V~ (+10% -15%)
Maximum current draw from mains| 5A @230V~
8.5A @115V~
Nominal output voltage| 26V  ±10%
Maximum output ripple| 200mV pp
 Maximum output current of the power group (Imax b according to EN54-4)| 38A @230V~
32A @115V~
Maximum current for external loads (Imax a according to EN54-4)| 35A @230V~
29A @115V~
Imin| 100mA
Power factor (at full load)|  0.95 @ 230V~
0.99 @ 115V~
Overvoltage protection (% of the declared potential)| CAT II 2500 V
Overvoltage category| 105 / 135
Overload protection| 29 / 33 V
Batteries| 2 x 12V 38Ah, NP38-121
2 x 12 V 24 Ah, NPL24-12I
2 x 12 V 17 Ah, NP 17 -12-FR
Maximum voltage charge adapted to temperature| 3A
Battery charger| 0.1Ohm
Maximum internal resistance of battery (Ri Max)| 19,5V
Battery shutdown voltage| -5°C +40°C
Operating temperature| 28V
Isolation class| I
Consumpt ion @ 27.6V| stand-by| 20mA
maximum| 40mA
mains fault| 30mA
Maximum voltage on OUT 1| 1.5A @27.6V
Maximum voltage on OUT 2| 1.5A @27.6V
Maximum voltage on RELAY| 5A, 30V
IFAMEVAC
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Consumption @ 27.6V| 100mA
A /B PAGER lines| micropho ne bases per line| Max 64
 current per line| Max 1 Vrms
total cable length per line| Max 1A
MUSIC 1/2 and AUX 1/2 input voltage| Max 500m
MUSIC 1/2 and AUX 1/2 input impedance| 10K Ohm
IFAMAMP
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| stand-by| 530mA
during mains failure and not in an
emergency situation|
maximum| Max 100mA (2.5W)
Speaker lines LINE A / B| voltage of outputs| 10A (250W + 14W)
maximum load| Max 100 Vrms
minimum resistance| 250W
Audio input LOCAL AUDIO| input voltage| 40Ohm
input impedance| Max 1 Vrms
Frequency response| 50 – 20000 Hz
Separate volume adjustment for MUSIC 1/2 sources, voice and emergency
announcements| +6 / -40 dB
Separate 3-band equalization for MUSIC 1/2 sources, voice and emergency
announcements| +6 / -40 dB
IFM2L
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Maximum number of devices managed by a loop| 240
Consumpt ion @ 27.6V| stand-by| 35mA
maximum| 50mA
Maximum voltage on Loop-A| 0.5A
Maximum voltage on Loop-B| 0.5A

inim CPR-2741 Previdia Ultravox Fire Detection Control Panel -
fig

Mains and grounding connectioninim CPR-2741 Previdia Ultravox Fire Detection
Control Panel - Batteries connectionBatteries connectioninim CPR-2741
Previdia Ultravox Fire Detection Control Panel - Cable
entryCable entryinim
CPR-2741 Previdia Ultravox Fire Detection Control Panel - polarized
devicesConnection of polarized devices (sirens, etc.) to OUT terminalsinim CPR-2741 Previdia Ultravox Fire Detection Control Panel -
Connection

Connection of nonpolarized devices (relays, coils, etc.) to OUT terminalsinim CPR-2741 Previdia Ultravox Fire Detection Control Panel -
Relay connectionRelay connection as generic indicationinim CPR-2741 Previdia
Ultravox Fire Detection Control Panel - fault signallingRelay connection as fault signalling (factory-assigned)inim CPR-2741 Previdia Ultravox Fire Detection Control
Panel - unbalanced audioConnection of unbalanced audio sources (MUSIC 1/2AUX 1/2)inim
CPR-2741 Previdia Ultravox Fire Detection Control Panel - Connection of
balancedConnection of balanced audio sources (MUSIC 1/ 2, AUX 1/2)inim
CPR-2741 Previdia Ultravox Fire Detection Control Panel - with
priorityConnection of audio sources (MUSIC 1/2, AUX 1/2) with priority requestinim CPR-2741
Previdia Ultravox Fire Detection Control Panel - supervised
speaker

100Vrms nonsupervised speaker outputinim CPR-2741 Previdia Ultravox Fire
Detection Control Panel - speaker output100Vrms supervised speaker output

inim CPR-2741 Previdia Ultravox Fire Detection Control Panel - Microphone
basesMicrophone bases connection
LINE A/B
2 pole cable, as required by the reference legislation
Cablesinim CPR-2741 Previdia Ultravox Fire Detection Control Panel - Speaker
outputs

Speaker outputs, single line connection
inim CPR-2741 Previdia Ultravox Fire Detection Control Panel - line
connectionSpeaker outputs, dual line connectioninim CPR-2741 Previdia Ultravox Fire Detection
Control Panel - Speaker outputs, loopSpeaker outputs, loop connection
LOCAL AUDIO
2 pole twisted shielded pair cable
Cables inim CPR-2741 Previdia Ultravox Fire Detection Control Panel -
Unbalanced sourceUnbalanced source with IAS-ADAPT1000inim CPR-2741 Previdia
Ultravox Fire Detection Control Panel - Balanced sourceBalanced source with IAS-ADAPT1000
Note
The cable segmentoutside of the shield must be short as possible inim
CPR-2741 Previdia Ultravox Fire Detection Control Panel - Loop
connection

IEC 62368-1
solation class

Terminal type / AC INPUT ES3, PS3
BATTERY ES1, PS3
RELAY ES1, PS2
OUT1, OUT2 ES1, PS2
EXPANSION BOARD ES1, PS2
RS485-BMS, RS485-REPEATER ES1, PS2
CAN-IN, CAN-OUT ES1, PS2
TAMPER ES1, PS1
USB ES1, PS1
CR2032 (J2) ES1, PS1
RS232 ES1, PS1
LOOP-A, LOOP-B ES1, PS2
ETHERNET ES1, PS1
MUSIC 1/2 ES1, PS1
AUX 1/2 ES1, PS1
A/B PAGERS ES1, PS2
LINE A/B ES3, PS3
LOCAL AUDIO ES1, PS1

Regulation (EU) No 305/2011 This product complies with requirements stated by standards listed here below in compliance with Regulation (EU) No. 305/2011.
Directive 2014/53/EU Hereby, INIM Electronics S.r.l. declares that the Previdia Ultra control panels are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. This product may be used in all EU Countries.
Documents for the users Declarations of Performance, Declarations of Conformity and Certificates concerning to INIM Electronics S.r.l. products may be downloaded free of charge from the web address www.inim.it, getting access to Extended Access and then selecting “Certifications” or requested to the e-mail address [email protected] or requested by ordinary mail to the address shown in this manual.
Manuals may be downloaded free of charge from the web address www.inim.it, getting access to Extended Access and then selecting “Manuals”.
0051
INIM Electronics s.r.l.
Via Dei Lavoratori 10 – Fraz. Centobuchi
63076 Monteprandone (AP) – Italy
22 0051-CPR-2741
EN 54-2:1997 + A1:2006
EN 54-4:1997 + A1:2002 + A2:2006
EN 54-16:2008
EN 54-21:2006
EN 12094-1:2003
PREVIDIA-ULTRAVOX
PREVIDIA-ULTRAVOXR
PREVIDIA-ULTRAVOXD
Control and signalling panel with power-supply equipment, alarm transmission and fault signalling equipment, automatic electrical device for control and management of switch off and delay, control and signalling equipment for integrated voice alarm systems for fire detection and signalling in buildings and for gas extinguishing systems installed in buildings as part of a complete operating system.

Essential features Performance
Performance in the event of fire PASS
Power supply performance PASS
Response delay (response time in the event of fire) PASS
Transmission performance PASS
Operating reliability PASS
Durability of operating reliability: Thermal resistance
Vibration resistance PASS
Humidity resistance PASS
Electrical stability PASS
Options provided in accordance with EN54-2 Performance
--- ---
7.8 Output to fire alarm devices PASS
7.9 Output to fire alarm routing equipment PASS
7.10 Output to fire protection equipment PASS
7.11 Delay on outputs PASS
7.12 Co-incidence detection (Type A, B and C) PASS
7.13 Alarm counter PASS
8.3 Point fault signal PASS
8.9 Output to remote fault or warning signalling devices PASS
9.5 Addressable points out-of-service PASS
10.0 Test condition PASS
Options provided in accordance with EN12094-1 Performance
4.17 Delay of extinguishing signal PASS
4.18 Signal representing the flow of extinguishing agent PASS
4.19 Monitoring of the status of components PASS
4.20 Emergency hold device PASS
4.21 Control of flooding time PASS
4.22 Initiation of secondary flooding PASS
4.24 Triggering signals to equipment within the system PASS
4.26 Triggering of equipment outside the system PASS
4.27 Emergency abort device PASS
4.28 Control of extended discharge PASS
4.29 Release of the extinguishing media for selected flooding zones PASS
Options provided in accordance with EN 54-16 Performance
7.3 Audible warning PASS
7.5 Phased evacuation PASS
7.6.2 Manual silencing of voice alarm status PASS
7.7.2 Manual reset of voice alarm status PASS
7.8 Output to fire signalling devices PASS
7.9 Voice alarm status output PASS
8.3 Fault signalling related to the transmission path to the CCS PASS
8.4 Fault signalling related to voice alarm zones PASS
9 Out-of-service condition PASS
10 Manual command of the voice alarm system PASS
12 Emergency microphone(s) PASS
13.14 Redundant power amplifiers PASS

Additional information according to EN 54-2
About information required at point 12.2.1, see data contained in this manual.
Additional information according to EN 54-4
For the information required by point 7.1, see data contained in this manual.
Additional information according to EN 54-21
For the information required by point 7.2.1, see data contained in this manual.
Additional information according to EN 12094-1
Environmental class: A
Degree of protection: IP30 Flooding zones: up to 24
Zones from 1 a 24 for CO2, inert gas or halogenated hydrocarbons. Response delay activation condition: max 3s
Response delay triggering of outputs: max 1s

This symbol indicates to installer to refer to the instructions manual.
Warranty Inim Electronics S.r.l.. (Seller, Our, Us) warrants the original purchaser that this product shall be free from defects in materials and workmanship under normal use for a period of 24 months.
As Inim Electronics does not install this product directly, and due to the possibility that it may be used with other equipment not approved by Us;Inim Electronics does not warrant against loss of quality, degradation of performance of this product or actual damage that results from the use of products, parts or other replaceable items (such as consumables) that are neither made nor recommended by Inim Electronics. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller’s option, any product not meeting the specifications. In no event shall Inim Electronics be liable to the purchaser or any other person for any loss or damage whether direct of indirect or consequential or incidental, including without limitation, any damages for lost profits, stolen goods, or claims by any other party caused by defective products or otherwise arising from the incorrect or otherwise improper installation or use of this product.
This warranty applies only to defects in parts and workmanship relating to normal use. It does not cover damage arising from improper maintenance or negligence, damage caused by fire, flood, wind or lightning, vandalism, fair wear and tear.
Inim Electronics S.r.l. shall, at its option, repair or replace any defective products. Improper use, that is, use for purposes other than those mentioned in this manual will void the warranty. Contact Our authorized dealer, or visit our website for further information regarding this warranty.
Limited warrantyInim Electronics S.r.l. shall not be liable to the purchaser or any other person for damage arising from improper storage, handling or use of this product.
Installation of this Product must be carried out by qualified persons appointed by Inim Electronics. Installation of this Product must be carried out in accordance with Our instructions in the product manual.
Copyright The information contained in this document is the sole property of Inim Electronics S.r.l.. Copying, reprinting or modification of this document, in part or as a whole, is not permitted without prior authorization in writing from Inim Electronics S.r.l.. All rights reserved.
WEEE Informative notice regarding the disposal of electrical and electronic equipment (applicable in countries with differentiated waste collection systems) The crossed-out bin symbol on the equipment or on its packaging indicates that the product must be disposed of correctly at the end of its working life and should never be disposed of together with general household waste. The user, therefore, must take the equipment that has reached the end of its working life to the appropriate civic amenities site designated to the differentiated collection of electrical and electronic waste. As an alternative to the autonomousmanagement of electrical and electronic waste, you can hand over the equipment you wish to dispose of to a dealer when purchasing new equipment of the same type. You are also entitled to convey for disposal small electronic-waste products with dimensions of less than 25cm to the premises of electronic retail outlets with sales areas of at least 400m2, free of charge and without any obligation to buy. Appropriate differentiated waste collection for the subsequent recycling of the discarded equipment, its treatment and its environmentally compatible disposal helps to avoid possible negative effects on the environment and on health and favours the re-use and/or recycling of the materials it is made of. Information about disposal of batteries and accumulators (applicable in Countries with separate collection systems)
This marking on batteries and/or their manual and/or their packaging, indicates that batteries of this products, at the end of their working life, should not be disposed of as unsorted municipal waste, but must be object of a separate collection. Where marked, the chemical symbols Hg, Cd o Pb indicate that the battery contains mercury, cadmium or lead above the reference levels of the directive 2006/66/EC. If batteries are not properly disposed of, these substances, together with other ones contained, can cause harm to human health and to the environment. To protect human health and the environment, to facilitate treatment and recycling of materials, separate batteries from other kind of waste and use the collection scheme stated in your area, in accordance to current laws. Before disposing of the above, it’s appropriate to remove them from their holders avoiding to damage them or causing short circuits.
Download

https://www.inim.biz/en/files/previdia-ultra-installation-manual- pdf

Inim Electronics S.r.l.
Centobuchi, via Dei Lavoratori 10
63076 Monteprandone (AP), Italy
Tel. +39 0735 705007 _ Fax +39 0735 704912
[email protected] 
www.inim.it
ISO 9001 Quality Management certified by BSI with certificate number FM530352inim CPR-2741 Previdia Ultravox Fire Detection Control Panel - bear