inim CPR-2741 Previdia Ultravox Fire Detection Control Panel Instruction Manual
- June 17, 2024
- INIM
Table of Contents
CPR-2741 Previdia Ultravox Fire Detection Control Panel
Instruction Manual
CPR-2741 Previdia Ultravox Fire Detection Control Panel
CONTROL PANEL FOR FIRE DETECTION AND ALARM AND VOICE-EVACUATION SYSTEMS
Technical specifications
Previdia-Ultravox
Dimensions | 433 x 677 x 258 mm |
---|---|
Weight | 23 Kg |
Protection grade |
FPMCPU
Power supply voltage| 19-30V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| stand-by| 130mA
maximum| 140mA
mains fault| 110mA
Maximum voltage on RS485-REPEATER| 1A @27.6V
Maximum voltage on RS485-BMS| 1A @27.6V
FPAMIAS
Power supply voltage| 20-30V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| maximum| 110mA
mains fault| 60mA
IFAMPSU
Power supply voltage| 50/60 Hz
230V~ (+10% -15%)
115V~ (+10% -15%)
Maximum current draw from mains| 5A @230V~
8.5A @115V~
Nominal output voltage| 26V ±10%
Maximum output ripple| 200mV pp
Maximum output current of the power group (Imax b according to EN54-4)| 38A
@230V~
32A @115V~
Maximum current for external loads (Imax a according to EN54-4)| 35A @230V~
29A @115V~
Imin| 100mA
Power factor (at full load)| 0.95 @ 230V~
0.99 @ 115V~
Overvoltage protection (% of the declared potential)| CAT II 2500 V
Overvoltage category| 105 / 135
Overload protection| 29 / 33 V
Batteries| 2 x 12V 38Ah, NP38-121
2 x 12 V 24 Ah, NPL24-12I
2 x 12 V 17 Ah, NP 17 -12-FR
Maximum voltage charge adapted to temperature| 3A
Battery charger| 0.1Ohm
Maximum internal resistance of battery (Ri Max)| 19,5V
Battery shutdown voltage| -5°C +40°C
Operating temperature| 28V
Isolation class| I
Consumpt ion @ 27.6V| stand-by| 20mA
maximum| 40mA
mains fault| 30mA
Maximum voltage on OUT 1| 1.5A @27.6V
Maximum voltage on OUT 2| 1.5A @27.6V
Maximum voltage on RELAY| 5A, 30V
IFAMEVAC
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Consumption @ 27.6V| 100mA
A /B PAGER lines| micropho ne bases per line| Max 64
current per line| Max 1 Vrms
total cable length per line| Max 1A
MUSIC 1/2 and AUX 1/2 input voltage| Max 500m
MUSIC 1/2 and AUX 1/2 input impedance| 10K Ohm
IFAMAMP
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Consumpt ion @ 27.6V| stand-by| 530mA
during mains failure and not in an
emergency situation|
maximum| Max 100mA (2.5W)
Speaker lines LINE A / B| voltage of outputs| 10A (250W + 14W)
maximum load| Max 100 Vrms
minimum resistance| 250W
Audio input LOCAL AUDIO| input voltage| 40Ohm
input impedance| Max 1 Vrms
Frequency response| 50 – 20000 Hz
Separate volume adjustment for MUSIC 1/2 sources, voice and emergency
announcements| +6 / -40 dB
Separate 3-band equalization for MUSIC 1/2 sources, voice and emergency
announcements| +6 / -40 dB
IFM2L
Power supply voltage| 20-30 V
Operating temperature| -5°C +40°C
Maximum number of devices managed by a loop| 240
Consumpt ion @ 27.6V| stand-by| 35mA
maximum| 50mA
Maximum voltage on Loop-A| 0.5A
Maximum voltage on Loop-B| 0.5A
Mains and grounding connectionBatteries connectionCable entryConnection of polarized devices (sirens, etc.) to OUT terminals
Connection of nonpolarized devices (relays, coils, etc.) to OUT terminalsRelay connection as generic indicationRelay connection as fault signalling (factory-assigned)Connection of unbalanced audio sources (MUSIC 1/2AUX 1/2)Connection of balanced audio sources (MUSIC 1/ 2, AUX 1/2)Connection of audio sources (MUSIC 1/2, AUX 1/2) with priority request
100Vrms nonsupervised speaker output100Vrms supervised speaker output
Microphone bases
connection
LINE A/B
2 pole cable, as required by the reference legislation
Cables
Speaker outputs, single line connection
Speaker
outputs, dual line connectionSpeaker outputs, loop connection
LOCAL AUDIO
2 pole twisted shielded pair cable
Cables Unbalanced source with IAS-ADAPT1000Balanced source with IAS-ADAPT1000
Note
The cable segmentoutside of the shield must be short as possible
IEC 62368-1
solation class
Terminal type / | AC INPUT | ES3, PS3 |
---|---|---|
BATTERY | ES1, PS3 | |
RELAY | ES1, PS2 | |
OUT1, OUT2 | ES1, PS2 | |
EXPANSION BOARD | ES1, PS2 | |
RS485-BMS, RS485-REPEATER | ES1, PS2 | |
CAN-IN, CAN-OUT | ES1, PS2 | |
TAMPER | ES1, PS1 | |
USB | ES1, PS1 | |
CR2032 (J2) | ES1, PS1 | |
RS232 | ES1, PS1 | |
LOOP-A, LOOP-B | ES1, PS2 | |
ETHERNET | ES1, PS1 | |
MUSIC 1/2 | ES1, PS1 | |
AUX 1/2 | ES1, PS1 | |
A/B PAGERS | ES1, PS2 | |
LINE A/B | ES3, PS3 | |
LOCAL AUDIO | ES1, PS1 |
Regulation (EU) No 305/2011 This product complies with requirements stated by
standards listed here below in compliance with Regulation (EU) No. 305/2011.
Directive 2014/53/EU Hereby, INIM Electronics S.r.l. declares that the
Previdia Ultra control panels are in compliance with the essential
requirements and other relevant provisions of Directive 2014/53/EU. This
product may be used in all EU Countries.
Documents for the users Declarations of Performance, Declarations of
Conformity and Certificates concerning to INIM Electronics S.r.l. products may
be downloaded free of charge from the web address
www.inim.it, getting access to Extended Access and then
selecting “Certifications” or requested to the e-mail address
info@inim.it or requested by ordinary mail to the
address shown in this manual.
Manuals may be downloaded free of charge from the web address
www.inim.it, getting access to Extended Access and then
selecting “Manuals”.
0051
INIM Electronics s.r.l.
Via Dei Lavoratori 10 – Fraz. Centobuchi
63076 Monteprandone (AP) – Italy
22 0051-CPR-2741
EN 54-2:1997 + A1:2006
EN 54-4:1997 + A1:2002 + A2:2006
EN 54-16:2008
EN 54-21:2006
EN 12094-1:2003
PREVIDIA-ULTRAVOX
PREVIDIA-ULTRAVOXR
PREVIDIA-ULTRAVOXD
Control and signalling panel with power-supply equipment, alarm transmission
and fault signalling equipment, automatic electrical device for control and
management of switch off and delay, control and signalling equipment for
integrated voice alarm systems for fire detection and signalling in buildings
and for gas extinguishing systems installed in buildings as part of a complete
operating system.
Essential features | Performance |
---|---|
Performance in the event of fire | PASS |
Power supply performance | PASS |
Response delay (response time in the event of fire) | PASS |
Transmission performance | PASS |
Operating reliability | PASS |
Durability of operating reliability: | Thermal resistance |
Vibration resistance | PASS |
Humidity resistance | PASS |
Electrical stability | PASS |
Options provided in accordance with EN54-2 | Performance |
--- | --- |
7.8 Output to fire alarm devices | PASS |
7.9 Output to fire alarm routing equipment | PASS |
7.10 Output to fire protection equipment | PASS |
7.11 Delay on outputs | PASS |
7.12 Co-incidence detection (Type A, B and C) | PASS |
7.13 Alarm counter | PASS |
8.3 Point fault signal | PASS |
8.9 Output to remote fault or warning signalling devices | PASS |
9.5 Addressable points out-of-service | PASS |
10.0 Test condition | PASS |
Options provided in accordance with EN12094-1 | Performance |
4.17 Delay of extinguishing signal | PASS |
4.18 Signal representing the flow of extinguishing agent | PASS |
4.19 Monitoring of the status of components | PASS |
4.20 Emergency hold device | PASS |
4.21 Control of flooding time | PASS |
4.22 Initiation of secondary flooding | PASS |
4.24 Triggering signals to equipment within the system | PASS |
4.26 Triggering of equipment outside the system | PASS |
4.27 Emergency abort device | PASS |
4.28 Control of extended discharge | PASS |
4.29 Release of the extinguishing media for selected flooding zones | PASS |
Options provided in accordance with EN 54-16 | Performance |
7.3 Audible warning | PASS |
7.5 Phased evacuation | PASS |
7.6.2 Manual silencing of voice alarm status | PASS |
7.7.2 Manual reset of voice alarm status | PASS |
7.8 Output to fire signalling devices | PASS |
7.9 Voice alarm status output | PASS |
8.3 Fault signalling related to the transmission path to the CCS | PASS |
8.4 Fault signalling related to voice alarm zones | PASS |
9 Out-of-service condition | PASS |
10 Manual command of the voice alarm system | PASS |
12 Emergency microphone(s) | PASS |
13.14 Redundant power amplifiers | PASS |
Additional information according to EN 54-2
About information required at point 12.2.1, see data contained in this manual.
Additional information according to EN 54-4
For the information required by point 7.1, see data contained in this manual.
Additional information according to EN 54-21
For the information required by point 7.2.1, see data contained in this
manual.
Additional information according to EN 12094-1
Environmental class: A
Degree of protection: IP30 Flooding zones: up to 24
Zones from 1 a 24 for CO2, inert gas or halogenated hydrocarbons. Response
delay activation condition: max 3s
Response delay triggering of outputs: max 1s
This symbol indicates to installer to refer to the instructions manual.
Warranty Inim Electronics S.r.l.. (Seller, Our, Us) warrants the original
purchaser that this product shall be free from defects in materials and
workmanship under normal use for a period of 24 months.
As Inim Electronics does not install this product directly, and due to the
possibility that it may be used with other equipment not approved by Us;Inim
Electronics does not warrant against loss of quality, degradation of
performance of this product or actual damage that results from the use of
products, parts or other replaceable items (such as consumables) that are
neither made nor recommended by Inim Electronics. Seller obligation and
liability under this warranty is expressly limited to repairing or replacing,
at Seller’s option, any product not meeting the specifications. In no event
shall Inim Electronics be liable to the purchaser or any other person for any
loss or damage whether direct of indirect or consequential or incidental,
including without limitation, any damages for lost profits, stolen goods, or
claims by any other party caused by defective products or otherwise arising
from the incorrect or otherwise improper installation or use of this product.
This warranty applies only to defects in parts and workmanship relating to
normal use. It does not cover damage arising from improper maintenance or
negligence, damage caused by fire, flood, wind or lightning, vandalism, fair
wear and tear.
Inim Electronics S.r.l. shall, at its option, repair or replace any defective
products. Improper use, that is, use for purposes other than those mentioned
in this manual will void the warranty. Contact Our authorized dealer, or visit
our website for further information regarding this warranty.
Limited warrantyInim Electronics S.r.l. shall not be liable to the purchaser
or any other person for damage arising from improper storage, handling or use
of this product.
Installation of this Product must be carried out by qualified persons
appointed by Inim Electronics. Installation of this Product must be carried
out in accordance with Our instructions in the product manual.
Copyright The information contained in this document is the sole property of
Inim Electronics S.r.l.. Copying, reprinting or modification of this document,
in part or as a whole, is not permitted without prior authorization in writing
from Inim Electronics S.r.l.. All rights reserved.
WEEE Informative notice regarding the disposal of electrical and
electronic equipment (applicable in countries with differentiated waste
collection systems) The crossed-out bin symbol on the equipment or on its
packaging indicates that the product must be disposed of correctly at the end
of its working life and should never be disposed of together with general
household waste. The user, therefore, must take the equipment that has reached
the end of its working life to the appropriate civic amenities site designated
to the differentiated collection of electrical and electronic waste. As an
alternative to the autonomousmanagement of electrical and electronic waste,
you can hand over the equipment you wish to dispose of to a dealer when
purchasing new equipment of the same type. You are also entitled to convey for
disposal small electronic-waste products with dimensions of less than 25cm to
the premises of electronic retail outlets with sales areas of at least 400m2,
free of charge and without any obligation to buy. Appropriate differentiated
waste collection for the subsequent recycling of the discarded equipment, its
treatment and its environmentally compatible disposal helps to avoid possible
negative effects on the environment and on health and favours the re-use
and/or recycling of the materials it is made of. Information about disposal of
batteries and accumulators (applicable in Countries with separate collection
systems)
This marking on batteries and/or their manual and/or their packaging,
indicates that batteries of this products, at the end of their working life,
should not be disposed of as unsorted municipal waste, but must be object of a
separate collection. Where marked, the chemical symbols Hg, Cd o Pb indicate
that the battery contains mercury, cadmium or lead above the reference levels
of the directive 2006/66/EC. If batteries are not properly disposed of, these
substances, together with other ones contained, can cause harm to human health
and to the environment. To protect human health and the environment, to
facilitate treatment and recycling of materials, separate batteries from other
kind of waste and use the collection scheme stated in your area, in accordance
to current laws. Before disposing of the above, it’s appropriate to remove
them from their holders avoiding to damage them or causing short circuits.
Download
https://www.inim.biz/en/files/previdia-ultra-installation-manual- pdf
Inim Electronics S.r.l.
Centobuchi, via Dei Lavoratori 10
63076 Monteprandone (AP), Italy
Tel. +39 0735 705007 _ Fax +39 0735 704912
info@inim.it
www.inim.it
ISO 9001 Quality Management certified by BSI with certificate number
FM530352
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>