INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR User Manual

June 5, 2024
INIM

INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR

INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR Interior and coverINIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR
1

PRODUCT FEATURES

  1.  Mount screw location
  2.  Viewfinder location
  3.  Alignment DIP switch
  4.  Tamper protection
  5.  Connection terminal board
  6.  ALARM LED
  7.  Voltage-tester entry
  8.  Response time adjustment
  9.  Wire entry
  10.  Horizontal adjustment trimmer
  11.  Vertical adjustment screw
  12.  Beam alignment-level indicators
  13.  LensesINIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 2
  •  A DIP switch per l’allineamento della barriera superiore.
  •  B DIP switch per l’allineamento della barriera inferiore.
  •  ALARM (rosso) si accende in caso di segnale di allarme.
  •  I LED 1-10 indicano il livello dell’allineamento delle barriere.
  •  A.POWER (verde) si accende quando la barriera in alto è alimentata.
  •  B.POWER (verde) si accende quando la barriera in basso è alimentata.
  •  A DIP switch for the upper beam alignment.
  •  B DIP switch for the lower beam alignment.
  •  ALARM (red) is ON when the beam senses alarm conditions.
  •  LEDs 1-10 is ON indicate the level of the beam alignment.
  •  A.POWER (green) is ON when the upper beam is powered.
  •  B.POWER (green) is ON when the lower beam is powered.INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 3

INSTALLATION

  1.  Remove the screw and detach the cover from the backplate.
  2.  Pull the wire through the wire entry.
  3.  Mount the detector.
  4.  Connect the wires to the terminals.
  5.  Adjust the beam alignment.
  6.  Replace the coverINIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 4

Terminale Terminal| Ricevitore Trasmettitore

Receiver Transmitter

---|---
TAMPER

+

| Uscita antisabotaggio Tamper output




ALARM OUT

| | |
NO| Uscita d’allarme normalmente aperta Normally open alarm output
NC| Uscita d’allarme normalmente chiusa Normally closed alarm output
COM| Uscita d’allarme comunea

Common alarm output

POWER

+

| Ingresso alimentazione Power supply input
Terminale Terminal| Ricevitore Trasmettitore

Receiver Transmitter

---|---
TAMPER

+

| Uscita antisabotaggio Tamper output




ALARM OUT

| | |
NO| Uscita d’allarme normalmente aperta Normally open alarm output
NC| Uscita d’allarme normalmente chiusa Normally closed alarm output
COM| Uscita d’allarme comunea

Common alarm output

POWER

+

| Ingresso alimentazione Power supply input

Wall-mounting

  • 3a-1. Break off the wall-mount knockouts.
  • 3a-2. Use 15mm screws

Pole-mounting

  • 3b-1. Break off the wire-entry knockout and pull the wires through.
  • 3b-2. Break off the pole-mount knockouts.
  • 3b-3. Using the brackets, mount the detector to the pole.

INSTALLATION RECOMMENDATIONS

  • In placements where obstacles (such as trees or even full clothes-lines) are situated between the receiver and the transmitter.
  • In places where sunlight or car headlights shine directly onto the detector.
  • In places where the installation base is unstable.INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 5
  • In case of using many groups of detectors when long distance protection to avoid the mutual disturbance of light beams.INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 6

Modello

Model

| Distanza di copertura (m)

Protection distance (m)

| Dispersione (m)

Dispersion (m)

---|---|---
BD-Q100| 100| 2.8
BD-Q200| 200| 3.4

ALIGNMENT

  • Accurate beam-alignment optimizes the sensing capacity of the detector and thus improves security and lowers the false-alarm rate, especially in difficult environments.
  • After mounting the devices, correct alignment is achieved through the lens positions.
  • It is attained by rotating the optical axis horizontally or vertically: adjustments can be made within a ±90° horizontal angle and ±10° vertical angle.
  • The alignment level can be gauged in two ways:
  •  LEDs 1-10 light in accordance with the beam-alignment level; the more LEDs that light, the better the beam alignment level.
  • A good level is indicated by the activation of 7 LEDs.
  •  Voltage measurement at CHECK connectors:
  • Insert the tester probes into the voltage-tester entries and measure the voltage. A good level is indicated by a voltage of at least 1.45V (maximum measurable voltage is 1.85V)

Voltaggio misurato (V) Measured voltage (V)| 1.15| 1.30| 1.45| 1.60| 1.75| 1.85
---|---|---|---|---|---|---
Livello LED LED level| 5| 6| 7| 8| 9| 10

Accurate alignment

  •  Insert the viewfinder in its location.
  •  Adjust the optical axis until it is possible to see the opposite detector in the center of the target.
  •  Turn ON the TS switch and turn OFF the 2 switches of the DIP switches, both in the transmitter and in the receiver.
  •  Turn ON the 2 switches of the upper beams (A group) and adjust the optical axis until the fifth of the level indicators LEDs is ON.
  • Once the beams are set, turn OFF the 2 switches.
  • . Repeat the same procedure for the lower beams (B group).
  •  Once the alignment is set, turn OFF the TS switches and turn ON all the 2 switches

Quick alignment

  •  Turn ON all the TS and 2 switches of the DIP switches, both in the transmitter and in the receiver.
  •  Cover the B group lens and adjust the optical axis of the A group until the fifth of the level indicators LEDs is ON.
  • Once the beams are set, uncover the B group lens.
  •  Repeat the same procedure for the lower beams (B group).
  •  Once the alignment is set, turn OFF the TS switches.

RESPONSE TIME SETTING

  • If the receiver does not receive a signal from the transmitter within the set Response time, the detector will trigger an alarm.
  • The interval can be set by means of the screw inside the “RESPONSE TIME ADJ” entry and the values of the time are in a range from 50 to 700 msec.INIM BD-Q200 QUAD PHOTOELECTRIC BEAM DETECTOR 9

WARNING

  •  The device must be installed in accordance with the instructions herein.
  •  Do not touch the sensor surface as this may cause degradation of its performance.
  •  Ensure that the power supply is off before cleaning the detector with a soft lint-free cloth dampened with a small amount of alcohol.
  •  This product reduces the risk of intrusions but cannot be considered a guarantee of absolute security. Take all necessary precautions when protecting your premises.
  •  Once this product has been properly mounted and setup, carry out a walk test by creating motion in the protected area.

TECHNICAL SPECIFICATIONS

BD- Q100 BD-Q200

Supply voltage| 12 to 24 Vdc
Nominal voltage| 13.8 Vdc
Current draw (max.)| 100 mA| 105 mA
Operating Temperature| -25 to +55 °C
Environmental humidity| 5 to 95 %
Outdoor range| 100| 200
Indoor range| 300| 600
Beam characteristics| Pulse infrared quad beams
Response time| 50 to 700 msec (selectable)
Alarm time| 2 sec (± 1) nominal
Alarm Relay output| N.C. or N.O., 30 Vdc, 500 mA max.
Tamper output| N.C., 30 Vdc, 500 mA max.
Installation method| Wall or pole mount
Alignment angles| Horizontal 180° (± 90°), vertical 20° (± 10°)
IP grade| IP54
Weight| 3100 g (receiver + transmitter)
Casing| Black PC resin

TROUBLESHOOTING

Trouble

|

Possible cause

|

Solution

---|---|---
The LEDs do not go ON| Inadequate power supply.| Check the power supply and wiring.
The alarm LED does not go ON even when the beams are violated.| 1.  The receiver is picking up beams from other sources.

2.  The three beams are not violated simultaneously.

3. The response time is too short

| 1.  Remove the reflecting object or adjust the optical axis.

2.  Increase the response time.

In the event of beam violation, the alarm LED goes on but the

detector does not trigger an alarm.

| 1. There is a short circuit.

2.  The terminal wiring has not been completed correctly.

| Check all wiring.
The alarm LED is always ON.| 1. The optical axis is positioned incorrectly.

2.  There are obstacles between the transmitter and receiver.

3. The detector cover or lens is dirty.

| 1.  Adjust the optical axis.

2.  Remove the obstacle.

3.  Clean the detector with a soft lint-free cloth.

Intermittent alarm.| 1. Improper wiring.

2. Inadequate power-supply.

3.  Moving obstacles between the transmitter and receiver.

4. Unstable mounting base.

5. The optical axis is not well positioned.

6. The response time is too short.

7. The lenses do not emit beams.

| 1.  Check wiring.

2.  Check the power supply.

3.  Remove the obstacles.

4.  Stabilize the base.

5.  Adjust the optical axis.

6.  Increase the response time.

7.  Change the detector placements.

DECLARATION OF CONFORMITY

The declaration of conformity to the Directive 2004/108/CE may be consulted ISO 9001: 2008 REGISTERED COMPANY at www.inim.biz/dc.html