levenhuk RD40 Radiation Detector User Manual
- June 17, 2024
- levenhuk
Table of Contents
levenhuk RD40 Radiation Detector
Specifications
- Power supply: Built-in rechargeable lithium battery
- Battery life: Recharge once every 12 months
- Dimensions: Not specified
- Weight: Not specified
Product Information
The Ermenrich Ping RD40 Radiation Detector is a portable device designed for measuring radiation levels. It features LED indicators, a display screen, a buzzer for alerts, and various control buttons for easy operation. The device comes with a Type-C USB cable for charging and a user manual for reference.
Product Usage Instructions
Charging the Device
This device uses a built-in rechargeable lithium battery. To charge the
device, connect the included USB cable to the device and a DC adapter, then
plug it into an AC power supply.
Note: Remember to recharge the battery at least once every 12 months.
Getting Started
To power on/off the device, press and hold the Power/Confirm button for 3
seconds. By default, the device enters Radiation measurement mode. Press the
Power/Confirm button to switch to the main menu.
Usage
History Records: The device automatically saves history records after each measurement. Up to 10 records are stored, with new records overwriting the oldest. View history records by selecting the Records menu.
Data Deletion: Delete current and history data by selecting the Data deletion menu. Choose to delete current data or history records.
Alarm Value Setting: Adjust alarm values for radiation levels.
Unit Setting: Configure measurement units.
Time Setting: Set the date and time on the device.
Hibernation Setting: Adjust screen off time, auto power-off time, and screen brightness level in the Sleep menu.
Care and Maintenance
Battery Safety Instructions: Always switch off the device when not in
use. Recharge the device promptly when the battery is low. Avoid overheating
and complete battery discharge.
Use only the original charger.
Levenhuk International Warranty
The product is covered by the Levenhuk International Warranty.
FAQ
Q: How do I view history records on the device?
A: Select the Records menu to view saved history records.
Q: How often should I recharge the device’s battery?
A: The battery should be recharged at least once every 12 months.
Q: Can I adjust the screen brightness level on the device?
A: Yes, you can adjust the screen brightness level in the Hibernation
setting menu.
Levenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612,USA,
+1-813-468-3001,
contact_us@levenhuk.com
Levenhuk Optics s.r.o. (Europe): V Chotejně 700/7, 102 00 Prague 102,Czech
Republic, +420 737-004-919, sales-info@levenhuk.cz
Levenhuk®, Ermenrich® are registered trademarks of Levenhuk, Inc.
© 2006–2024 Levenhuk, Inc. All rights reserved.
www.levenhuk.com
20240202
PRODUCT OVERVIEW
- LED indicator
- Display
- Buzzer
- Left button
- Power/Confirm button
- Right button
- Power input
Ermenrich Ping RD40 Radiation Detector
Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.
The kit includes: radiation detector, Type-C USB cable, user manual, and warranty.
Charging the device
This device uses a built-in rechargeable lithium battery. Connect the USB
cable (included) to the device and the DC adapter (not included) via a USB
plug and connect it to the AC power supply to charge the device.
The battery needs to be recharged once every 12 months.
Getting started
Press (5) and hold it for 3s in order to turn the device on/off. The device
enters Radiation measurement mode by default. To switch to the main menu,
press (5).
When the device is locked, it is not possible to turn the device off. Select Schedule (Timed measurement) and click Stop timer (Stop the timer) to turn the timer off.
Usage
Radiation measurement
Select Measure (Radiation measurement) in the main menu to check the real-
time, average/cumulative dose rates, and total measurement time.
Timed measurement
Select Schedule (Timed measurement) to set the delay time. You can set the
delay value between 00 and 99h and a timer value between 00 and 999h. Click
Start timer (Start the timer). The device starts counting down. After the
Start delay countdown is completed, the real-time dose rate, average dose
rate, total measurement time, and cumulative dose rate are reset at the same
time. The device starts to Measure the real-time dose and cumulative dose
rate. After the countdown is finished and the measurement is completed, the
device automatically saves the measured data in the history record.
The Start delay (Start the delay time) setting is the countdown to starting
the measurement. It can be set in hours, minutes, and seconds. Press Start
timer (Start the timer) to enter countdown mode. The measurement starts after
the countdown is finished.
History records
A history record is automatically saved at the end of each measurement. When
10 history Records have been saved, the newly saved history record will
overwrite the oldest one. Select Records (History records) to view the history
records.
Data deletion
To delete the current data and history data, select Delete (Data deletion)
menu. Select Delete Current Data (Current data deletion) to delete the average
dose rate and total measurement time. Select Delete History Data (History data
deletion) to delete the history records.
Alarm value setting
Select Alarm (Alarm setting) to set the dose rate and total dose high alarm
values using (4) or (6). The device will emit an audible and visible alarm
signal when the radiation concentration exceeds the set alarm values.
Real-time dose rate limit value setting range: 0.1-999µSv.
Total dose rate limit value setting range: 1-9999µSv.
Unit setting
Select Unit (Unit of measurement setting) in the main menu. Press (4) or (6)
to switch between µSv and µGy.
Sound setting
Select Sound (Audio setting) to set the alarm volume (0 to 9 levels), the
number of alarms (0 to 10 times), and the particles Sound (on/off). If the
particles sound is on, the device will emit sound when the sensor detects ion
particles.
Time setting
Select Clock (Time setting) to set the date and current time.
Date setting: Year > Month > Day
Time setting: Hours > Minutes > Seconds
Hibernation setting
Select Sleep (Hibernation setting) to set the screen off time (in minutes),
auto power-off time (in hours), and screen brightness level.
Specifications
Dose measurement range | 0.08µSv… 50mSv |
---|---|
Cumulative dose range | 0.1µSv… 9999mSv |
Exposure dose rate (EDR) measurement range, µSv/h | 0.08µSv/h… 50mSv/h |
Sensor | Geiger–Müller counter tube |
Measurement accuracy | –17%…+25% based on 137Cs γ |
Measurement time | < 10s |
Audible alarm | + |
Visual alarm | + |
Timer | + |
Display | 2.0″ LCD color screen |
History records | 10 sets |
Water-/dustproof certification | IP3X |
Charging time | 3–4 hours |
Operating temperature range | –20… +50°C / –4… +122°F (operating/storage) |
Power supply | rechargeable Li-ion battery, 3.7V, 750mA·h; 24V, 1A adapter for |
charging (not included)
Battery life| two weeks (provided that the particles sound is off)
Dimensions| 88x43x19 mm
Weight| 50g
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
The device is designed to measure X-, β- and γ-radiation. The values for X-radiation are reference values. Do not expose the device to strong radiation. Do not use the device in explosive atmospheres. Do not use the device in humid and dust environments. Store the device in a dry cool place. Do not expose the device to shock, continuous vibrations, or extreme high or low temperatures. Do not try to disassemble the device on your own for any reason. For calibration, repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Only use accessories and spare parts for this device that comply with the technical specifications. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.
Battery safety instructions
The device is equipped with a built-in rechargeable lithium-ion battery. This
avoids frequent battery replacement. Always switch the device off when not in
use. If the battery charge is low, please recharge the device in time to
ensure that the measurements are accurate. Do not overheat the battery. Do not
discharge the battery completely. Only use the original charger.
Levenhuk International Warranty
Levenhuk products, except for their accessories, carry a 5-year warranty
against defects in materials and workmanship. All Levenhuk accessories are
warranted to be free of defects in materials and workmanship for six months
from the purchase date. The warranty entitles you to the free repair or
replacement of the Levenhuk product in any country where a Levenhuk office is
located if all the warranty conditions are met.
For further details, please visit:
levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
References
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
- Levenhuk’s official website in USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>