PS-INV-12.5KW-60A-XX Savant Power Storage User Guide

June 17, 2024
SAVANT

PS-INV-12.5KW-60A-XX Savant Power Storage
User Guide

PS-INV-12.5KW-60A-XX Savant Power Storage

PS INV 12.5KW 60A XX Savant Power Storage - qr code1 Savant Power Storage [60A]
Quick Reference Guide

Box Contents
(1) Savant Power Inverter (PS-INV-12.5KW-60A-XX)
(8) Power Storage 20 Battery (PS20-BATT-20KWH)
(1) Savant Power Director
(1) Battery Crate (8 x Modules)
(1) Conduit Nipple Kit
(1) Mounting & Installation Kit
(4) M5x12 Screws
(4) M5x10 Screws
(4) M10 Expansion Screws
(4) M6 Expansion Anchor Screw

Specifications

Environmental

Temperature| Inverter: -13°F to 131°F (-25°C to 55°C)
Battery: 32°F to 113°F (0°C to 45°C)
Humidity| 0% to 95% Relative Humidity (non condensing)
Altitude Rating| Less than 9842 ft
Rating| NEMA4X

Dimensions and Weights

Height Length Depth Weight
85.4 in (216.92 cm) 25.6 inch (65.02 cm) 12.2 inch (30.988 cm) 600 lbs

(272.15 kg)
Inverter Power
Maximum Output Current| Grid Transfer Time| Maximum Surge Output| Maximum Passthrough Per Inverter
12.5 kW| < 70ms| 16 kVA, 10s 21 kVA, 20ms| 60A

Battery Power

Battery Capacity 52 Ah / 20 kWh
Maximum Power 12.5kW

Standards

Wi-Fi 2.4 GHz IEEE 802.11 b/g/n

Regulatory

Safety and Emissions FCC Part 15 Class B ****
Contains FCC ID: 2AA9B10
Certifications UL 1741 SA, UL 1741 PCS, UL9540, UL 1973, UL 1642, UL 1998,

CSA 22.2
RoHs| Compliant

Inverter Front Panel Right Panel Left Panel

PS INV 12.5KW 60A XX Savant Power Storage - Right
Panel

Descriptions

A Inverter Status LEDs See Inverter Status LEDs.
B Inverter Front Panel Remove panel to reveal inverter wiring area.
C ON/OFF Button Power on or off the Savant Power Storage.
D Grid Switch Connect or disconnect the Grid input.
E Conduit Knock- outs Knockouts for AC Conductor Conduits.
F Antennas Wi Fi, GPS, 4G Main, and 4G DIV Antennas
G Reset Button Press to reset inverter status.
H PV Switch Emergency off switch for PV arrays.
I Battery and Communication Caps Waterproof caps.
J Network Network connection for the inverter to communicate with the

greater Savant Power System.
K| PV Inputs| MPPT Inputs.
L| I/O Ports| See Inverter I/O Ports.
M| Inverter Wiring| Pre-installed inverter wiring.
N| Battery Inputs| Battery power inputs.
O| GRID, LOAD, & GEN Connections| Grid, Load, and Generator connections.
P| Ground| Inverter & battery grounding connections.

Inverter I/O Ports

PS INV 12.5KW 60A XX Savant Power Storage - Ports

Front Input/Outputs

A Status LED Table See the Status LED table
B Network RJ45 connection for wired internet connection
C USB Ports Used for local software updating.
D SD Enables local data collection without internet connection.
E Reset Reset button to reset inverter status.
F CLED Power input for LEDs.
G GPIO Ports See the Savant Power Storage 20 Installation Guide.
H BCMS Battery Monitor System Communication Port
I RS-485Port See the Savant Power Storage 20 Installation Guide.

Inverter Status LEDs

PS INV 12.5KW 60A XX Savant Power Storage - Status
LEDs

Status LEDs & Inverter States

A| Network| Solid Red: Energy management unit startup in progress.
Blinking Red: Ready for network connection.
Blinking Green: Wi-Fi network and password detected, or Ethernet cable detected, connecting to router.
Solid White: Connecting to the Internet.
Solid Green: Internet connected successfully.
---|---|---
B| Status| Blinking Blue: System updating.
Blinking Red: Communication fault between energy management unit and battery system, inverter unit, or PV unit.
Solid Red: Energy management unit internal communication fault.
Blinking Green: System is turned off by energy management unit.
Solid Green: System running normally.
C| Power| On: Grid, Generator, or Load power is normal.
Off: No power input
Blinking: Grid, Generator, or Load power is abnormal.
D| Run| Solid Green: Inverter/PV charging unit running normally
Solid Red: Inverter unit fault.
Solid Yellow: PV charging unit fault, or system into over-temperature protection.
Blinking Yellow: Inverter/PV charging unit alarming.
Blinking Green: Inverter unit/PV charging unit updating.

BMS Access Panel

PS INV 12.5KW 60A XX Savant Power Storage - Access
Panel

A 12V DC Battery enclosure 12VDC connection.
B REF, BAT+ & BAT- Positive, negative, and REF battery connections.
C Ground Ground connection to Power Storage 20.
D CAN CANBUS Port to communicate with the Savant inverter.
E Fuse Box Overcurrent protection for battery modules.
F System SoC Total system State of Charge in 25% increments.
G Battery System Status Indicator Blinking Yellow: Battery System is

starting up or an update in progress.
Blinking Blue: Battery System is in SelfInspecting mode.
Solid Green: Running normally.
Solid Yellow: An alarm has been raised.
Solid Red: A fault has been detected.

Battery Access Panel

PS INV 12.5KW 60A XX Savant Power Storage - Access
Panel1

A Power Switch Toggle ON or OFF all batteries.
B Reset Button Press to restart battery system.
C Status LED Blinking Yellow: Startup or update in

progress
Blinking Blue: Self-inspecting
Solid Green: Running normally
Solid Yellow: Alarming
Solid Red: Protection/Fault
D| Start Button| Press to start battery system.
E| Battery Status LED| Blinking Yellow: Startup or update in progress
Blinking Blue: Battery Module is in SelfInspecting mode.
Solid Green: Running normally.
Solid Yellow: An alarm has been raised.
Solid Red: A fault has been detected.

Bracket Installation

  1. Open the battery enclosure with a PH2 Philips screwdriver and remove the accessories kit.
  2. Assemble the bracket as shown using M5x12 screws.PS INV 12.5KW 60A XX Savant Power Storage - Access Panel2
  3. Attach the bracket to the back side of the battery system with M5x12 machine screws. Tighten to 26.5 in-lbs torque.
  4. Drill a 1/2 in (12mm) hole with a 2.75 in (70mm) depth into the floor. Embed the anchor expansion bolts and affix the cabinet to the ground.PS INV 12.5KW 60A XX Savant Power Storage - Inverter1
  5. Install the bracket on the wall with M6x50 tapping screws.
    IMPORTANT NOTES:
    – When installing it on a concrete wall, properly drill into the wall with M6x50 expansion anchor screws.
    – If Savant Power Inverter is installed separately from battery system, install the bracket on a surface capable of supporting its weight using M6x50 tapping screw. Then hang Savant Power inverter on the bracket, and fasten it with M4x16 screws.

Inverter Installation

  1. Remove the battery seal cap marked BAT/COM on the bottom left of the Savant Power Inverter.

  2. Remove the Battery Status panel side communication cable panel.PS INV 12.5KW 60A XX Savant Power Storage - Inverter

  3. Hang the inverter on the bracket.

  4. Fasten the Savant Power Inverter and the bracket with M5x12 machine screws. (Torque: 26.5 in-lbs).

  5. Fasten Savant Power Inverter and the battery cabinet with conduit and screw kit, as shown.PS INV 12.5KW 60A XX Savant Power Storage - Inverter2

  6. Number all battery labels with a number 1-8.

  7. Install battery 8 in the bottom battery slot. Then continue to install all batteries in ascending slots in reverse numerical order, with battery 8 on the bottom and battery 1 in the top. See the diagram to the right for reference.
    NOTE: Always keep the batteries connected in the order that they were originally installed.

  8. Fasten all modules on both sides using M4x8 screws (Torque: 10.5 in-lbs).

Inverter Installation

  1. Connect battery system to the Savant Power Inverter with ground wire.PS INV 12.5KW 60A XX Savant Power Storage - Inverter4
  2. Make the REF, BAT- , BAT+ connections from the inverter through the conduit to the corresponding connections in the battery access panel through the conduit.
  3.  Connect the DC 12V wire between the inverter and the battery battery access panel.
  4. Connect the BCMS port of the Savant Power Inverter to the CANBUS connection of the Battery Status Panel.PS INV 12.5KW 60A XX Savant Power Storage - Inverter7
  5. Make all connections between the inverter and the electrical system. For more information, see the Savant Power Storage 20 Deployment Guide.PS INV 12.5KW 60A XX Savant Power Storage - Inverter5
  6. (Optional) Connect Savant Power Storage 20 to photovoltaic array. NOTE: The diagram below represents DC coupled PV arrays.PS INV 12.5KW 60A XX Savant Power Storage - Inverter6
  7. Connect Savant Power Storage 20 to the same network switch as the Power Director OR the network port of the Power
  8. Director itself using a CAT5 or higher Ethernet cable.PS INV 12.5KW 60A XX Savant Power Storage - Inverter8

More Information
To continue deployment and configure the Savant Power Storage 20, see the following documentation.

Savant Power Storage App Setup Guide

|

Savant Power Storage 20 Installation Guide

---|---
| PS INV 12.5KW 60A XX Savant Power Storage - qr code1

<https://support.savant.com/redirect?qrParm=SPS20-Commissioning-Guide>

|

<https://support.savant.com/redirect?qrParm=PowerStorage20_Install-Manual>  

Copyright © 2023 Savant Systems, Inc
090523 009-2396-00
Savant Power Storage QRG [60A]
45 Perseverance Way, Hyannis MA 02601
www.savantpower.com | 508.683.2500

Documents / Resources

| SAVANT PS-INV-12.5KW-60A-XX Savant Power Storage [pdf] User Guide
PS-INV-12.5KW-60A-XX Savant Power Storage, PS-INV-12.5KW-60A-XX, Savant Power Storage, Power Storage, Storage
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SAVANT User Manuals