BRESSER 7004030 CO2 Air Quality Monitor Smile XXL
Product Information
- Product Name: CO2 Air Quality Monitor Smile XXL
- Article Number: 7004030
- Power Supply: AC/DC power adapter
Technical Specifications:
- Response Time: Within 10 seconds of any change in CO2
- Carbon Dioxide Measurement Range: 0 – 9999 PPM
- Accuracy: 1 PPM
- Temperature Resolution: Not specified
- Temperature Accuracy: Not specified
- Humidity Measuring Range: 0 to 99.9% RH
- Humidity Resolution: 0.1%
- Humidity Accuracy: Not specified
- Work Condition: Not specified
- Storage Condition: Not specified
- Dimensions: 388x288x43 mm
- Weight: 1.435 kg
Product Usage Instructions
- Connect the AC/DC power adapter to the DC Anschlussbuchse (DC connection socket) located at the back of the device.
- Mount the CO2 Air Quality Monitor on a wall using the provided wall mounting screws.
- Press the MODE button to set the carbon dioxide concentration alarm value. Use the Increase and Decrease buttons to adjust the alarm value as desired
- The graphical display on the front of the device shows the current CO2 level. The display will indicate whether the air quality is Poor (1200-9999PPM), Good (600-1100PPM), or Excellent (0-500PPM).
- The PPM Value displayed on the front of the device represents the concentration of carbon dioxide in the ambient air, measured in parts per million.
- Use the MODE button to switch between Celsius and Fahrenheit temperature units.
Note: For detailed instructions, please refer to the Bedienungsanleitung (Instruction Manual) available for download at www.bresser.de/P7004030.
GENERAL WARNINGS
RISK OF CHOKING!
Keep packaging material, like plastic bags and rub-ber bands, out of the reach
of children, as these ma-terials pose a choking hazard.
RISK of ELECTRIC SHOCK!
This device contains electronic components that operate via a power source (ac
adaptor). Only use the device as described in the manual; otherwise, you run
the risk of an electric shock.
RISK of FIRE/EXPLOSION!
Do not expose the device to high temperatures. Excessive heat or improper
handling could trigger a short-circuit, a fire or an explosion.
RISK of property damage!
Do not disassemble the device. In the event of a de-fect, please contact your
dealer. The dealer will con-tact the Service Centre and can send the device in
to be repaired, if necessary.
EC DECLARATION OF CONFORMITY
Hereby, Bresser GmbH declares that the equipment type with part number: 7004030 is in compliance with Directive: 2014/30/EU and 2014/35/EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/7004030/CE/7004030_CE.pdf
UKCA Declaration of Conformity
Bresser GmbH has issued a „Declaration of Conformity“ in accordance with
applicable guidelines and corresponding standards. The full text of the UKCA
declaration of conformity is available at the following internet address:
www.bresser.de/download/7004030/UKCA/7004030_UKCA.pdf
Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8
6HF, Great Britain
MANUAL DOWNLOAD:
SCOPE OF DELIVERY
TECHNICAL DATA
Power supply | AC/DC power adapter DC 9V 2000 mA |
---|---|
Response Time | Within 10 seconds of any change in CO2 |
Carbon dioxide measurement range | 0 – 9999 PPM |
Accuracy | ± 70 PPM ±3% readings |
Resolution | 1 PPM |
Temperature measuring range | -10° to +100°C |
Temperature resolution | 0.1°C |
Temperature accuracy | ±0.3°C |
Humidity measuring range | 0 to 99.9% RH |
Humidity resolution | 0.1% |
Humidity accuracy | ±3% |
Work condition | 0 – 50° C (0 – 90% RH) |
Storage condition | -30 – 70° C (0 – 90% RH) |
Dimensions | 388x288x43 mm |
Weight | 1.435 kg |
FRON
- Graphical display of current CO2 level.
- PPM Value. PPM stands for “parts per million” and shows the concentration of carbon dioxide in the ambient air.
- Temperature
- Humidity
BACK
-
MODE button
Set carbon dioxide concentration alarm value -
button
Increase the alarm value -
button
Decrease the alarm value -
button
Alarm on/off -
°C/°F button Switch Celsius/Fahrenheit
-
Horizontal wall mounting holes
-
Vertical wall mounting holes
-
DC power interface
CO² LEVEL
CO² level | Status | Description |
---|---|---|
250 – 350ppm | Outside | Normal outdoor air level. |
350–1000ppm | Well ventilated, Ideal | Typical level indoors with good |
ventilation. 1000 ppm = Recommended maximum level in a closed room. Con-
sidered maximum comfort level in many countries.
1000–1200ppm| Under ventilated| Poor air quality – requires ventilation.
General drowsiness, discomfort and odors.
1200–2000ppm| Very under ventilated| Fatigue and sleepiness may set in.
Intensify ventilation measures!
2000–5000ppm| Very poorly ventilated| Danger! You may experience severe
headaches, vomit- ing/nausea, and dizziness within 20 minutes.
above 5000ppm| Totally unacceptable| Danger! Headache and dizziness in 5 to 10
minutes. Increased risk for health damage by prolonged exposure.
WALL MOUNT
Use the wall plugs and wall mounting screws to attach the device to your
wall in horizontal or vertical position.
CHARGING / START-UP
Insert the DC connector into the connection socket (8) of the device.
Insert the mains plug into the power outlet. The device is energized directly
and begins preheating. The LCD displays a countdown of 7 sec-onds. The buttons
are not operational during this time. Once the countdown is finished the
device enters the normal measurement state.
SETTINGS MODE
Press the MODE button to enter the carbon dioxide alarm settings mode. Press
or to choose the PPM value when the alarm should start. Press the MODE button
to confirm and exit the settings mode. The default alarm value is 1200 PPM.
CARBON DIOXIDE ALARM
Press the Alarm button to activate or deactivate the carbon dioxide alarm.
When you hear a small beep sound, then the alarm is activated. The alarm will
sound once the concentration of carbon dioxide reach-es the alarm value. Press
the alarm button again during an active alarm to deactivate the alarm sound.
CLEANING AND MAINTENANCE
Before cleaning the device, disconnect it from the power supply (disconnect power adapter)! Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
DISPOSAL
- Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
- Do not dispose of electronic devices in the household garbage! As per Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
WARRANTY
The regular warranty period is 2 years and begins on the day of purchase. To
benefit from an extended voluntary warranty period as stated on the gift box,
registration on our website is required.
You can consult the full warranty terms as well as information on extending
the warranty period and de-tails of our services at
www.bresser.de/warranty_terms.
Please contact the service centre first for any questions regarding the
product or claims, preferably by e-mail.
E-Mail : service@bresseruk.com
**Telephone*** : +44 1342 837 098
BRESSER UK Ltd.
Suite 3G, Eden House
Enterprise Way
Edenbridge, Kent TN8 6HF
United Kingdom
*Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
References
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- index · powered by h5ai 0.26.1 (http://larsjung.de/h5ai/)
- Bresser | BRESSER CO2-Messgerät Smile XXL mit CO2-Ampel und extragroßem LED-Display | Expand Your Horizon
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>