ELITechGroup Temtop H3 TVOC Air Quality Monitor Rechargeable
Overview
The detector can accurately detect formaldehyde and 1VOC concentration. With a high-precision electrochemical formaldehyde sensor, it can directly transform the concentration of formaldehyde and 1VOC in the air into visual data, providing air quality alert to effectively safeguard your family.
Application
Indoors, Outdoors, Vehicles, etc
Appearance
Specification
- Name: Portable formaldehyde detector
- Model: H3
- Display: TFT color LCD screen
- Battery voltage: 3.7VDC
- Power adapter:
- charge voltage: 5VDC
- charge current: 1A
- Dimensions: 177″65.5*32 mm
- Operating environment:
- Temperature: o-50°C (32-122°F)
- Humidity: 0-90%RH
- Air pressure: 1 atm
- Measurement range:
- Formaldehyde measurement technical index
- Range: 0-5mg/ m3
- Resolution: 0.01mg/m3
- 1VOC measurement technical index
- Range: 0-5mg/ m3
- Resolution: 0.01mg/m3
Health Parameters Guide
HCHO
(mg/m 3)
| TVOC
(mg/ m3)
| ****
Level
---|---|---
0-0.1| 0-0.5| Healthy
0.1| >0.5| Unhealthy
Operation
- TUm on/off the detector Press and hold power bull 2 seconds 1D tum on/off the deflector.
- Manual calibration
- Press and hold the button “CAL” for 4 seconds to enter calibration status, the screen will display calibration information. Place the detector outdoor for 10 minutes and calibration ends. Press any button in the calibration process, the detector will 8lCit calibration mode, indicating an invalid calibration.
- Detect the concentration of HCHO and TVOC Place the calibra1sd deleckJr i1 the target environment, and It will automatically detect HCHO and TVOC concen1ratlon.
- Power Indication
- Battery full
- Battery low. Please charge.
- SWllch of dlsplay content
Interference Gas| Relative Sensitivity(%)
---|---
Carbon monoxide (CO)| 1
Hydrogen sulfide (H, 5)| I
Hydrogen (H,)| 0.1
Sulphur dioxide (SO,)| 12
Nitrogen dioxide (NO,)| I
Nitric oxide (NO)|
Chlorine (Cl)| -3
Ethylene (C,H.)| I
Ammonia (NH, )| 0
Carbon dioxide (CO,)| 0
Methanol, ethanol| 50
Phenols| 7
MOD :
Press it 1D shift between the display interface and graph interface.
CAL:
Press it for 4 seconds to enter or exit calibration mode
11/ ► :
Press the button ii detection mode, Iha deliver holds currently displayed data
and “Hold’ appean1 on the lop of the screen. Press it again, the detector
respond real-time detection &talus and ‘Nlrnlng” appears on the mp of the
screen
Operation Notice
- Don oot put the detector in an environment where the concentration of formaldehyde is over 1.0mglm” for long time. Long-Ume enclosure to high concentration air pollutants will damage the Iha sensor and make n work improperly.
- Please put the detector in a ventilated environment for 6 hours when you use n for the first time to avoid the Influence of micro intervening gas Inside the package.
- It is normal to display a higher value when the detector is turned on for Iha first time or unused for a long time. Place it in ventilation to accelerate data recovery.
- Before detection, please keep the room airtight for 10 minutes. The detadDr will provide more accurate data. Please lake the average value of multiple points detected in different places of the room 1D know its overall air quality.
- Avoid contact with organic solvents that include silica gel and other adhesives, paintings, drugs, oil, and high-<: ClncentraUon gases.
- Avoi
- d using the detect In humid enviromental1 n:i to make sure the accuracy of last data.
- Avoid bumps, strikes and drops.
- Do not power the detection port when using the detector.
- Ba cautious of access inlBrfllrenca.
Due lo its electrochemical reaction characteristic, the sensor may respond to other gases besides the 1arget gas. Please avoid using the dalBdcr In the environment containing the following gases ID guarantees the accuracy;y of data. Interference ga888 are as foll0W8:
Warranty Rule
Temp warranty the included detector for 1 year from the date of original purchase. The Hem can be exchanged or returned within 30 days if the defect is not caused by artificial damage
Item | Warranty Period |
---|---|
Detector | 1 year included |
Accessories | N/A |
Before returning or delivering for repair, please check If the following items are ready
| Detector & Accessories| Complete Package| Proof of **Purchase***|
Gift (if any)
---|---|---|---|---
Return| | | |
Exchange| | | |
Repair| | | |
- Temp warranty does NOT include:
- malfunction or damages caused by artificial damage or modification.
- Other deliberate damages.
- Damages caused by force majeure.