HUDSON VALLEY 5142 Sennett LED Chandelier Instruction Manual

June 17, 2024
HUDSON VALLEY

HUDSON VALLEY 5142 Sennett LED Chandelier

HUDSON-VALLEY-5142-Sennett-LED-Chandelie-product

Product Information

  • Product Name: Hudson Valley Lighting
  • Product Model: Sennett 5142
  • Manufacturer: Hudson Valley Lighting Group
  • Website: http://www.hvlgroup.com

Specifications

  • Replacement Parts:
    • Hardware Kit (PART A)
    • Hex Nuts (PART E)
    • Plate Cap Nut (PART G)
    • Canopy Assembly (PART H)
    • Chain (PART J)
    • Alabaster Driver (PART L)
  • Fixture Installation:
    • MOUNTING PLATE (A)
    • MOUNTING SCREWS (B)
    • CABLE CLAMP (N)
    • SAFETY CABLE (O)
    • FIXTURE ASSEMBLY (K) with LED
    • Junction box rated for minimum 90 lbs
    • Ground wire (Green)
    • Neutral wire (White)
    • Hot wire (Black)

Product Usage Instructions

Fixture Installation

  1. Using the MOUNTING PLATE (A) as a template, mark the holes for the THREADED ROD (P) on the building structure, following local building codes.
  2. Slide the crimp type CABLE CLAMP (N) onto the SAFETY CABLE (O). Feed the SAFETY CABLE (O) down through one of the holes in the top of the outlet box. Loop the SAFETY CABLE (O) over the approved support, then feed it back through the top of the box and the CABLE CLAMP (N). Use the crimping tool to tightly crimp the CABLE CLAMP (N) to lock the SAFETY CABLE (O) in position.
  3. Open the end link on the CHAIN (J) and attach it to the loop on the FIXTURE ASSEMBLY (K) (WITH LED). Hang the FIXTURE ASSEMBLY (K) (WITH LED) on the CHAIN (J) at your desired height, and remove any excess CHAIN (J).
  4. Feed the wire through the CHAIN (J), LOOP (I), and CANOPY (H).
  5. Pull the wire out of the Junction box and attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B), WASHER (Q), and NUT (R). Ensure that the junction box is securely mounted to the structure of the building and can support a minimum of 90 lbs.
  6. Attach the Ground wire (Green) to the ground inside the outlet box or the GROUND SCREW (C) on the MOUNTING PLATE (A). Never connect the Ground wire to the Hot wire as it may result in serious injury or death.
  7. Connect the neutral DRIVER (M) lead to the neutral wire (Generally white) in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1 inch below the fastener, tightly wrap the connection with electrical tape to seal the end of the fastener. Ensure there are no exposed wires or strands that could cause a dangerous short circuit.
  8. Connect the hot leads of the DRIVER (M) to the hot wire (Generally black) in the junction box. Fasten the joined wires as in the previous step. Never reverse the Hot and Neutral wires as it may result in serious injury or death. Push the electrical wires back into the junction box.
  9. Lift up the CANOPY (H) to the ceiling and secure it with the HEX NUTS (E), placing the DRIVER (M) into the CANOPY (H).
  10. Open the top link on the CHAIN (J), and hang the FIXTURE ASSEMBLY (K) (WITH LED) onto the LOOP (I) on the CANOPY (H). Hide any excess wires in the CANOPY (H). Attach the male connector from the fixture into the female connector from the DRIVER (M).
  11. Lift up the PLATE (F), and attach it using the CAP NUTS (G).
  12. Restore power to the outlet at the breaker or fuse box.

FAQ

  • Q: Where can I find replacement parts for the Hudson Valley Lighting Sennett 5142?
    • A: You can find replacement parts on our website, http://www.hvlgroup.com, under the “Replacement Parts” section.
  • Q: How do I ensure that the fixture is securely mounted to the building structure?
    • A: Follow local building codes and affix the THREADED ROD (P), WASHER (Q), and NUT (R) to the building structure. The THREADED ROD (P) must be a minimum of 41 and meet the requirements specified in the local building codes.
  • Q: Can I connect the Ground wire to the Hot wire?
    • A: No, never conn`ect the Ground wire (Green) to the Hot wire (Black). This can result in serious injury or death. Always connect the Ground wire to the ground inside the outlet box or the GROUND SCREW (C) on the MOUNTING PLATE (A).
  • Q: What should I do if there are exposed wires or strands?
    • A: Ensure that there are no exposed wires or strands that could cause a dangerous short circuit. If you notice any exposed wires, cover them with electrical tape to prevent any accidents.

WARNING

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

Installation Instructions

HUDSON-VALLEY-5142-Sennett-LED-Chandelie-
fig-1 HUDSON-VALLEY-5142-Sennett-LED-Chandelie-
fig-2

  1. Using the MOUNTING PLATE (A) as a template mark the holes for the THREADED ROD (P) (BY OTHERS). NOTE: THREADED ROD (P), WASHER (Q), and NUT (R) (BY OTHERS) must be minimum of
    ” and affixed to the building structure following local building codes.

  2. Slide crimp-type CABLE CLAMP (N) onto the safety cable. Feed the SAFETY CABLE (O) down through one of the holes in the top of the outlet box. Loop the SAFETY CABLE (O) over the approved support. Feed the SAFETY CABLE (O) back through the top of the box and the CABLE CLAMP (N). Using the crimping tool, tightly crimp the CABLE CLAMP (N) to lock the SAFETY CABLE (O) in position.

  3. Open the end link on the CHAIN (J) and attach to the loop on the FIXTURE ASSEMBLY (K) (WITH LED). Hang the FIXTURE ASSEMBLY (K) (WITH LED) on the CHAIN (J) at your desired height, and remove excess CHAIN (J).

  4. Feed the wire through the CHAIN (J) , LOOP (I), and CANOPY (H).

  5. Pull the wire out of the Junction box and attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B), WASHER (Q), and NUT (R). This fixture is designed to be mounted on a heavy-duty round or octagon junction box rated for a minimum 90 lbs. The junction box must be securely mounted to the structure of the building.

  6. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!

  7. With the DRIVER (M) in hand Connect the neutral DRIVER (M) lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connection seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!

  8. Connect the DRIVER (M) hot leads to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!. Push electrical wires back into the junction box.

  9. Lift up the CANOPY (H) up to the ceiling and secure with the HEX NUTS (E) placing the DRIVER (M) into the CANOPY (H)

  10. Open the top link on the CHAIN (J), and Hang the FIXTURE ASSEMBLY (K) (WITH LED) to the LOOP (I) on the CANOPY (H). Hide the excess wires in the CANOPY (H). Attach the male connector from fixture into the female connector from DRIVER (M).

  11. Lift up the PLATE (F), and attach using the CAP NUTS (G).

  12. Restore power to the outlet at the breaker or fuse box.