HUDSON VALLEY H871704 Delia 3 Light Pendant Instruction Manual

May 15, 2024
HUDSON VALLEY

HUDSON VALLEY H871704 Delia 3 Light Pendant

HUDSON-VALLEY-H871704-Delia-3-Light-Pendant-product

Specifications

  • Model: DELIA H871704
  • Manufacturer: Hudson Valley Lighting
  • Fixture Type: Pendant Light
  • Maximum Wattage: 8 watts (Type G16.5 lamp)

Fixture Installation

  1. Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B).
  2. Hang the FIXTURE ASSEMBLY (J) on the CHAIN (I) at your desired height.
  3. Feed the wire through the CHAIN (I), SCREW COLLAR (G), CANOPY (H), SCREW COLLAR LOOP (F), NIPPLE (E), and MOUNTING PLATE (A).
  4. Hang the FIXTURE ASSEMBLY (J) to the SCREW COLLAR LOOP (F).
  5. Cut off excess wire, strip the insulation off the end of the leads.
  6. Attach the Ground wire (Green) to the ground inside the junction box or the GROUND SCREW (C) on the MOUNTING PLATE (A).
  7. Connect the fixture lead to the neutral wire in the outlet box and fasten with an approved fastener.
  8. Connect the smooth fixture leads to the hot wire in the junction box and fasten.
  9. Lift up the CANOPY (H) to the ceiling and secure with the SCREW COLLAR (G).
  10. Screw the BULB (L) into the SOCKET of the fixture. Do not exceed 8 watts.
  11. Place the SHADE (K) into the FIXTURE ASSEMBLY (J).
  12. Restore power at the breaker or fuse box.

FAQ

What type of bulb should I use with this fixture?
This fixture is rated for a maximum 8-watt Type G16.5 lamp. Donot exceed the recommended wattage.

How do I properly connect the wires?
Make sure to connect the ground wire to the ground and the neutral wire to neutral. Always follow proper wiring procedures to avoid serious injury or death.

Can I replace any parts of the fixture?
Yes, you can replace parts with the following replacement part names and codes:

  • SCREW COLLAR AND LOOP: SCL-H871703
  • CANOPY: CPY-H871704
  • CHAIN: CHN-CN1005
  • SHADE: SHD-H871704

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

DELIA
H871704

Installation Instructions

HUDSON-VALLEY-H871704-Delia-3-Light-Pendant-1

FIXTURE INSTALLATION

  1. Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
  2. Open the end link on the CHAIN (I) and attach to the loop on the FIXTURE ASSEMBLY (J). Hang the FIXTURE ASSEMBLY (J) on the CHAIN (I) at your desired height, and remove excess CHAIN (I).
  3. Feed the wire through the CHAIN (I) , SCREW COLLAR (G), CANOPY (H), SCREW COLLAR LOOP (F), NIPPLE (E), and MOUNTING PLATE (A), and screw the NIPPLE (E) onto the MOUNTING PLATE (A).
  4. Open the top link on the CHAIN (I), and Hang the FIXTURE ASSEMBLY (J) to the SCREW COLLAR LOOP (F).
  5. Cut off excess wire, and strip the insulation off the end of the leads.
  6. Attach the Ground wire (Green) to the ground inside the junction box (Generally green or bar copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  7. Connect the fixture lead the ridge(s) to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connections seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
  8. Connect the smooth fixture leads with to the hot (Generally black) wire in the junction box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  9. Push the wires back into the junction box. Lift up the CANOPY (H) up to the ceiling, and secure with the SCREW COLLAR (G).
  10.  Screw the BULB (L) up into the SOCKET of the fixture. THIS FIXTURE IS RATED FOR MAX 8 WATT TYPE G16.5 LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
  11. Place the SHADE (K) into the FIXTURE ASSEMBLY (J) of the fixture.
  12. Restore power to the outlet at the breaker or fuse box.
PART(S) REPLACEMENT PART NAME NUMBER
A,B,C,D,E HARDWARE KIT HDW-04
F,G SCREW COLLAR, AND LOOP SCL-H871703
H CANOPY CPY-H871704
I CHAIN CHN-CN1005
K SHADE SHD-H871704

www.hvlgroup.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HUDSON VALLEY User Manuals

Related Manuals