WARNING/ CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE ST
  • MAINTENANCE OF THIS URI SHOULD BE COMPLETED BY INCENSED ELECTRICIAN OR CERTIFIED FACTORY-TRAINED TEL
  • CASH RANDS AFTER USHIS LIGHTING FIXTURE CONTAIN CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE
  • DAMAGE ITLE DOES NOT PAY OR REME RSE ELECTRICIAN PENS. THE FIXTURE WAY MUST BE RETURNED ONCE PARAS HAS BEEN

Installation Instructions

FIXTURE INSTALLATION

  1. Attach the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on a standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
  2. Remove the SCREW COLLAR i) from the COLLAR LOOP (H). Fully thread the NIPPLE (C) onto the COLLAR LOOP (H). Thread the HEX NUT (E) onto the NIPPLE (C) along with the TOOTH WASHER (D). Then thread the NIPPLE (C) onto the MOUNTING PLATE (A). Adjust the NIPPLE (C) so that the threads of the COLLAR LOOP (H) extend & beyond the CANOPY (I). Secure using HEX NUT (E).
  3. Open the end link of the CHAIN (K) and attach it to the FIXTURE ASSEMBLY (L) at the desired height. Slide the SCREW COLLAR (1) and the CANOPY (J) onto the CHAIN (K). Open the link on the other end of the CHAIN (K) then attach to the COLLAR LOOP (H). Feed the wires through the CHAIN (K), SCREW COLLAR (1), CANOPY (1), COLLAR LOOP (H), NIPPLE (C), and MOUNTING PLATE (A).
  4. Cut off excess wires, and strip the insulation off the end of the leads.
  5. Attach the Ground wire to the ground inside the junction box (Generally green or bare copper wire) or the GROUND SCREW (F) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO ‘HOT WIRE! FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  6. Connect the fixture’s SPT Neutral (SPT WIRE WITH NO WRITINGS) wire lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (G). Starting 1′ below the fastener, tightly wrap the connection with electrical tape so that the connection seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRES OR STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT!
  7. Connect the fixture’s SPT hot (SPT WITH WRITINGS) wire lead to the hot (Generally black) wire in the junction box. Fasten the joined wires the same as in the previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH!
  8. Push the wires back into the junction box. Lift up the CANOPY (J) up to the ceiling, and screw the SCREW COLLAR (1) onto the COLLAR LOOP (H).
  9. Attach the LARGE SHADE (M), MEDIUM SHADE (N), and SMALL SHADE (O) onto the FIXTURE ASSEMBLY (L) and secure using THREADED SOCKET RING (P).
  10. Screw the BULB (Q) up into the SOCKET of the FIXTURE ASSEMBLY (L). THIS FIXTURE IS RATED FOR 25 WATT TYPE G40 LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE!
  11. Restore power to the OUTLET at the breaker or fuse box.