HUDSON VALLEY 1833-AGB Stampford Ten Light Chandelier Instruction Manual
- June 17, 2024
- HUDSON VALLEY
Table of Contents
HUDSON VALLEY 1833-AGB Stampford Ten Light Chandelier
WARNING/CAUTION
- DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
- TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURES MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY-TRAINED TECHNICIAN.
- CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
- UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE BEFORE INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
- PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.
STAMPFORD 1833
Installation Instructions
PARTS
PART(S) | REPLACEMENT PART NAME | NUMBER |
---|---|---|
A, B, C, D, E, O | HARDWARE KIT | HDW-05 |
F | STEM KIT | STM-ZS1900-KIT |
G | CANOPY | CPY-1833 |
H | ALLEN KEY TOOLING | TOL-1833 |
J | GLASS A | GLS-1831-A |
K | RING | RNG-1831 |
M | GLASS B | GLS-1831-B |
FIXTURE INSTALLATION
-
Slide crimp-type CABLE CLAMP (O) onto the safety cable. Feed the SAFETY CABLE (M) down through one of the holes in the top of the outlet box. Loop the SAFETY CABLE (M) over the approved support.
Feed the SAFETY CABLE (M) back through the top of the box and the CABLE CLAMP (O). Using the crimping tool, tightly crimp the CABLE CLAMP (O) to lock the SAFETY CABLE (M) in position. -
Feed the wire through the STEM KIT (F) and twist tightly onto the FIXTURE ASSEMBLY (I). Keep adding additional stems until your desired hanging height is met.
-
Slide in CANOPY (G) onto the STEM KIT (F), and thread the 1/4 NIPPLE (E) onto the top end of the STEM KIT (F)
-
Pull the wire out from the junction box, and install the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on a standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
-
Trim off the excess wire to a minimum of 6″ beyond the STEM and strip each wire 5 8″.
-
Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bare copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRE TO “HOT” WIRE FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH
-
Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wires together with an approved fastener (WIRE NUT) (D). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connection seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRES OR STRANDS THAT COULD CAUSE A DANGEROUS SHORT-CIRCUIT
-
Connect the black fixture leads to the hot (Generally black) wire in the outlet box. Fasten the joined wires the same as in the previous step. NEVER REERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH
-
Push the wires back into the junction box. Lift the CANOPY (G) to the ceiling, and secure with the HEADLESS SCREW by using supplied ALLEN KEY TOOLING (H)
-
Screw the GLASS A (J) up to the FIXTURE ASSEMBLY (I) and secure with the RING (K).
-
Screw the BULB (L) into the SOCKET of the fixture. THIS FIXTURE IS RATED FOR MAX 8 WATT-TYPE A15 LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE.
-
Screw the GLASS B (M) into the RING (K) of the fixture.
-
Restore power to the outlet at the breaker or fuse box.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>