DELTA HEC3512FFA Series Wall Mount User Manual

May 15, 2024
Delta

DELTA-LOGO

DELTA HEC3512FFA Series Wall Mount

DELTA-HEC3512FFA-Series-Wall-Mount-PRODUCT

Product Information

Features

  • Reliable and energy-efficient thermal solutions
  • Energy-efficient fans and effective compressor
  • IP55 waterproof on the external side
  • Precise temperature control
  • Earth-friendly refrigerant
  • Dry contact alarm output

Design

  • Compact size
  • Dual power input: Rated voltage at 48VDC and rated voltage at 230VAC 50/60Hz
  • Built-in smart controller
  • High efficiency and reliable fan
  • Easy installation and maintenance

Product Usage Instructions

Installation

  1. Choose a suitable location on the wall to mount the unit.
  2. Ensure that the wall is strong enough to support the weight of the unit.
  3. Use the dimension drawing provided to mark the correct position for mounting.
  4. Drill holes into the wall at the marked positions.
  5. Insert appropriate wall anchors into the drilled holes.
  6. Place the unit onto the wall, aligning it with the drilled holes.
  7. Securely fasten the unit to the wall using screws.

Maintenance

  • Regularly clean the external side of the unit to remove any dust or debris.
  • Check the fan for any signs of damage or obstruction.
  • If necessary, clean or replace the fan to ensure proper airflow.
  • Inspect the compressor for any leaks or abnormal noises.
  • If any issues are found, contact a qualified technician for repairs.

Troubleshooting

If you encounter any issues with the unit, refer to the troubleshooting section of the user manual or contact customer support for assistance.

FAQ

  • Q: Can this unit be used outdoors?
  • A: Yes, the unit is IP55 waterproof on the external side, making it suitable for outdoor use.
  • Q: What are the power requirements for this unit?
  • A: The unit has dual power input options – rated voltage at 48VDC and rated voltage at 230VAC 50/60Hz.
  • Q: Can the temperature be controlled precisely?
  • A: Yes, the unit offers precise temperature control for optimal cooling.
  • Q: Is the refrigerant used in this unit environmentally friendly?
  • A: Yes, the unit uses an earth-friendly refrigerant.
  • Q: How loud is the unit during operation?
  • A: The noise level of the unit, measured at a distance of 1.5 meters, is 65.0 dB-A.

Wall mount

DELTA-HEC3512FFA-Series-Wall-Mount-FIG-1Dimension drawing

DELTA-HEC3512FFA-Series-Wall-Mount-FIG-2

SPECIFICATIONS

Main feature Unit Specification

Dimension (H x W x D)

|

mm (inch)

|

1300 x 500 x 250

(51.2 x 19.7 x 9.8)

Cooling capacity*Note| W (BTU/hr)| 3500(11943) /50HZ
Rated voltage| VDC

VAC

| 48

230VAC 50/60 Hz

Operating current| A| 8.3
Operating voltage range| VDC

VAC

| 40 ~ 58

207 ~ 253

Operating temperature range| °C| -40 ~ +55
Noise (1.5 meter)| dB-A| 65.0
Weight| Kg (Lb)| 58 (128)

  • Note : L35/L35
  • Specifications are subject to change without notice.

Features

  • Reliable and energy-efficient thermal solutions.
  • Energy efficient fans and effective compressor.
  • IP55 waterproof on external side.
  • Precise temperature control.
  • Earth-friendly refrigerant.
  • Dry contact alarm output.

Design

  • Compact size.
  • Dual power input:
  • Rated voltage at 48VDC.
  • Rated voltage at 230VAC 50/60Hz.
  • Built-in smart controller.
  • High efficiency and reliable fan.
  • Easy installation and maintenance.