Important Information

Smart Hub is the powerful brain of Room Banker Secure & Automation system, enabling you to connect a variety of sensors and peripherals and then Duly your own security solution in a flexible and easy-to-use way.

Note: the external antennas need to be purchased separately

Capacity

Wireless peripheral (including RBF, ZigBee 3.0, Bluetooth devices)

  • Supports up to 128 peripherals (RBF, ZigBee, BLE devices)
    Specifically, up to 2 alarm keypad, 4 sirens, 32 key fobs, 2 repeaters

Users

  • Up to 69
User Type Quantity
Super Admin × 1
Admin × 4
App User × 32
Local User × 32

Automation scenes

Up to 64 custom scenes Alarm responses / Scheduled actions / Security mode changing reactions / Temperature changing reactions / Humidity changing reactions / Reactions to pressing Button

Rooms

  • Up to 64 rooms

Wireless communication

RBF communication technology

Innovative and Proprietary wireless communication technology to transmit information. Key features:

  • Ultra-long communication range.(868MHz: Up to 3.5km@open area)
  • Two-way communication.
  • AES-CCM encryption featuring a random key.
  • OTA by wireless.
  • Instant notifications.
  • Remote control via RB Link App.

Frequency bands

  • 868 MHz version: 863 ~ 870 MHz
    915 MHz version: 902 ~ 928 MHz Depends on sales region.

Wireless signal modulation

  • FSK / DSSS

Wireless signal range

  • 868MHz: Up to 3,500m in open space Between the hub and connected devices. Maximum range depends on the connected device.

Encrypted communication
All the data transmitted are protected by AES-CCM encryption with a random key.

Frequency hopping (FHSS)

  • up to 50 channels available to prevent radio interference and radio signal interception

Time division multiple access (TDMA)

  • With the help of clock synchronization technology, hub will slice time into different division for different RBF wireless devices. In this way, all devices will communicate with hub in a sequence.

Internet connection

Ethernet

  • 1 × RJ45 Ethernet connector: 10/100 Mbps

Cellular

  • 1 × Standard SIM slot
  • Cellular Band (LTE Cat1)

Region

|

LTE-FDD Band

| LTE-TDD

Band

| GSM

Band

---|---|---|---
EMEA / ASIA /

Australia / New Zealand

|

B1/ 3/ 5/ 7/ 8/ 20

|

|

B2/ 3/ 5/ 8

USA| B2/B4/B5/B12/B13/B14/B66/B71| –|

Latin America

|

B2/ 3/ 4/ 5/ 7/ 8/ 28/ 66

|

| B2/ 3/ 5/ 8

China

|

B1/ 3/ 5/ 8

| B34/ 38/ 39/ 40/ 41|

B3/ 8

Note: Select the right LTE region before ordering a hub.
External antenna optional for places where built-in antenna signal is bad or no signal.

Wi-Fi

  • 2.4G, 802.11 b/g/n

Communication channels prioritization

  1. Ethernet
  2. Wi-Fi
  3. Cellular connection
    Backup between Ethernet, Wi-Fi and SIM.

Notifications

Supported notification types

  • App notification Push / SMS / Phone Calls

Power Supply

External plug

  • Type-C, DC5V, 2A

Backup Battery

  • Built-in backup battery: 1 × 18650 lithium battery,2600mAh Up to 8 hours backup time

Anti-sabotage

Tamper alarm
The system receives notifications about attempts to detach the device from the surface or remove it from the mounting panel.
Anti-jamming
The users receive notifications in case of jamming or when the hub loses connection with the devices.

General

Dimension

  • 150mm × 150mm × 37mm

Weight

  • 320 g

Operating temperature range

  • from −10°C to +45°C

Complete set

Product Quantity
Home Security Hub with mounting panel × 1
Power Plug with Type-C cable (1m) × 1
Ethernet cable (1m) × 1
Screw package × 1
Quick Start Guide × 1
SIM Card Tray × 1
screwdriver × 1

Additional information

Available models


Hub

| ****

Model Name

| ****

RBF

| ****

ZigBee

| ****

Ethernet

| Wi- Fi| ****

GPRS

| ****

LTE

---|---|---|---|---|---|---|---
Station- GPRS| RBGW-201- 868| √| √| √| √| √| ×


Hub

| ****

Model Name

| ****

RBF

| ****

ZigBee

| ****

Ethernet

| Wi- Fi| ****

GPRS

| ****

LTE

---|---|---|---|---|---|---|---
| RBGW-201- 915| | | | | |


Station-LTE

| RBGW-202- 868

RBGW-202- 915

| ****

| ****

| ****

| ****

| ****

×

| ****

Note Station- LTE needs to select LTE region.

  • Region 1: EMEA / ASIA / Australia / New Zealand
  • Region 2: USA
  • Region 3: Latin America
  • Region 4: China

Certifications

  • CE, CB
  • FCC
  • ICASA
  • LOA
  • RCM
  • NOM
  • Anatol

User manual

  • Romancers User Manual

Warranty

  • Replacement and repair within 24 months of the date of sale

FCC Statement

  1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
  2. This device may not cause harmful interference.
  3. This device must accept any interference received, including interference that may cause undesired operation.
  4. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

To comply with RF exposure requirements, a minimum separation distance of 20cm must be maintained between the user’s body and the device, including the antenna.

Customer Support

 Hub Home Security Hub (Station) Specification

https://wiki.roombanker.com/hub/home-security-hub-station/specification 1/7

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Roombanker User Manuals

Related Manuals