Hangzhou Roombanker Technology DSHT-040 Room Thermostat User Guide

June 6, 2024
Hangzhou Roombanker Technology

DSHT-040 Room Thermostat
User Guide
Zigbee TYPE

Welcome,

Thank you for your purchase.
Your new thermostat will provide uniform and comfortable temperature control throughout every room in your peoperty. We bring together technology, craftsmanship, and the highest quality materials to provide you with a safe, reliable product combined with sleek, contemporary design. Please read this installation/programming manual for comprehensive instructions on installing and operating your thermostat. Please also ensure a suitably qualified person installs your thermostat and complies with all local regulations.

In the box you will find

Thermostat 1pc
User Guide 2pc
Screws 4pc
--- ---
QC Passed 1pc

SYSTEM TYPE

  1. Warm air, hot water, high-efficiency furnaces, heat pumps, steam, gravity.
  2. Heat only–including the power to open and close zone valves, and normally open zone valves.
  3. Heat only with a fan.
  4. Cool only.

FEATURES

On Appearance

  1. A negative black screen will bring you to a secret world.
  2. The 4.8-inch large colorful display creates your colorful life.
  3. Touch buttons to make simple operation.
  4. An amazing silver frame opens your modern life.
  5. The visible thickness above the wall is only 2cm (0.787 inches).
  6. The snap connection allows you to easily install.
  7. Wall-mounted or suitable for the installation of Europe, China, Japan, USA, and Italy, etc,.
  8. White, black, or brushed stainless steel for your selection.
  9. Wrap-around cooling holes help heat to escape quickly and increase the temperature sensing accuracy.
  10. 12 terminals are available for many systems.

On Functionality

  1. Powerful functions are available such as WIFI etc,
  2. 1 F /0. 5: accuracy keeps the temperature within the level you set.
  3. C or F choice.
  4. 7 days four periods programmable.
  5. Temporary programmable.
  6. Holiday mode.
  7. All setting languages synchronized your time zone, address, and language.
  8. No limit to add thermostats in App.
  9. Support Smart Scene.
  10. Support to make two-stage groups.
  11. Support device sharing.
  12. Weather, UV index, humidity display help you decide what to wear today.
  13. Support 3H2C Heat Pump system and 2H2C Conventional System etc,.

TECHNICAL DATA

Power Supply: 24VDC/AC ±10%
Current Load: 1A (Inductive) 3A (Resistance)
Sensor: NTC3950, 10K
Set Temp. Range: 42-122 F (5-50 C)
Accuracy: ±1 F
Display Temp. Range: 41210 F (5-99 C)
Ambient Temp: 32113 F (0-45 C )
Ambient Humidity: 5″95%RH(Non Condensing)
Storage Temp: 23113 F (-5-45 C)
Timing Error: <1%
Power Consumption: <1.5W
Shell Material: PC+ABS(Fireproof)
Available Installation 1: Wall mounted
Available Installation 2: Hole Distance of 62±5mm (Europe, China, and Japan)
Available Installation 3: Hole Distance of 86±3mm (USA and Italy etc,.)
Wire Terminals: Wire 2×1.5mm2 or 1×2.5mm2
Protection Class:
IP20 Buttons: Capacitive Touch Buttons

DIMENSION

HOME SCREEN QUICK REFERENCE

  1. Zigbee ( AP mode )
  2. Zigbee ( EZ mode )
  3. AUX Heat
  4. 1st Stage Heat +1: 2nd Stage Heat
  5. 1st Stage Cool +1: 2nd Stage Cool
  6. Fan
  7. Wind speed
  8. Weather
  9. Periods
  10. Monday to Sunday
  11. External sensor
  12. Ultraviolet intensity
  13. Outdoor Humidity
  14. Down Button
  15. Up Button
  16. Clock
  17. Permanent Hold/Temporary V—V Hold/Using Schedule/Hold Until (holiday)
  18. Auto/Cool/Heat/Off/EMER
  19. Power on/off
  20. Time Display
  21. Set temp. Menu
  22. Room Temp.
  23. Fan On/Auto
  24. System mode
  25. Lock/Unlock
  26. Filter Reminder
  27. Set Temp.

BEFORE WIRING AND INSTALLING

  1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
  2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.
  3. The installer must be a trained, experienced service technician.
  4. After installation is complete, check out product operation as provided in these instructions.

CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry.
Disconnect power supply before installation.
For wiring, please refer to another page.

INSTALLATION

Your thermostat can be mounted horizontally on the wall or on a 4 in. x 2 in. (101.6 mm x 50.8 mm) wiring box.
How to select the location?
Install your thermostat about 5 ft. (1.5m) above the floor in an area with good air circulation at an average temperature.

Don’t install your thermostat where it could be affected by:

  • Drafts or dead spots behind doors and in corners.
  • Hot or cold air from ducts.
  • Radiant heat from sun or appliances.
  • Concealed pipes and chimneys.
  • Unheated (uncooled) areas.

Steps
Step 1. Keep the electricity off.
Step 2. Remove the mounting plate. See Fig 1.

Step 3. Complete the wiring according to the wiring diagram and select the appropriate hole mounting screws. See Fig 2.

Step 4. Check whether the wiring is correct and look for the correct direction of the thermostat display panel. See Fig 3.

Step 5. Press the thermostat back onto the mounting plate to complete the installation. See Fig 4.

OPERATION

  1. Power On/off: Press Co to turn the thermostat on/off.
  2. Selecting System Mode: Press to select the mode AUTO, COOL, HEAT, OFF, EMER

HEAT — The thermostat controls the heating system.
OFF — Both heating and cooling systems are off.
COOL — The thermostat controls the cooling system.
AUTO — Thermostat automatically changes between heating and cooling operation, depending on indoor temperature.
EMER — Emergency heat cycles to maintain temperature. The compressor is locked out (used only for 2H/1C or 3H/2C heat pump systems) and auxiliary heat turns on as a second stage if needed.

3. Function and Programmable
Press C? to set the Permanent Hold, Temporary Hold, Using Schedule and hold until (holiday). The functions will appear on the screen.
Permanent Hold – Manual. In this mode, press to set temperature by manual.
Temporary Hold. During Using Schedule or in this mode, press to set the temporary temp.. It will be valid till the start time of the next scheduled period.
Using Schedule. 7 days a week, four periods programmable daily.
Holiday Mode. Changes temperature setting for a designated number of days.

How to set your time?
Press till the min of time will flash;
Touch the icon to set your minute.
Then press the hour of time will flash;
Touch the icon to set your hour.
Then press the week of time will flash; Touch the icon to set your week.

How to adjust your schedule?
Press four times in a row. (You can see Mcn and 1.1. ) Use the arrows to adjust the time for the 1st period(Get Up). Press the icon then use the gip arrows to set the temp. for the 1st period. Repeat this process for periods 2-4.
Get Up — Period when you awaken and want your home at a comfortable temperature.
Go Out — Period when you are away from home and want an energy-saving temperature.
Go Home — Period when you return home and want your home back to a comfortable temperature.
Sleep — Period when you are asleep and want an energy-saving temperature.

Factory Setting

Schedule Period Time Setpoints
Heat Cool
Get Up 6:00 AM 72οF
(22οC) 72οF

(22οC)
Go Out| 8:00 AM| 72οF
(22οC)| 72οF
(22οC)
Go Home| 11:30 AM| 72οF
(22οC)| 72οF
(22οC)
Sleep| 1:30 AM| 72οF
(22οC)| 72οF
(22οC)

How to adjust your holiday?
Press Cd till the letters Hold Until displays and days flash on the screen then click . arrows to set the days of holiday. When the flashing of days stops, you can press C47: arrows to set the temp. Holiday mode will be valid immediately.
4. Advanced Options:
In the off state, press for three seconds at the same time. Then press to change the different items. You can press arrows to change settings.

User Setup Number Function Setting and options Default
1 Fan ON / AUTO 0: Fan AUTO; 1: Fan ON 0
2 Temperature Calibration -8 ° F to 8 ° F (-4 ° C to 4 ° C) 0°F
3 Compressor delay time for heat pump 0-5 minutes 0
4 0: cooling 0/B = 0, heating 0/B = 1;
1: cooling 0/B = 1, heating 0/B = 0; 1

Changeover ValveTerminal
—O/B
Energized in Heating or Cooling (Heat Pumps Only). Only shown if heat pump system is chosen.
5| Minimum setting temperature| 42 ° F to 62 ° F (5 to 15 ° C)| 42°F (5°C)
6| Maximum setting temperature| 62 ° F to 122 ° F (15 to 45 °| 122°F(45°C)
7| Time display| 0: 12-hour clock; 1: 24-hour clock| 1
8| The dead-band temperature in Auto mode for a heat pump. Heating and cooling setpoints can be set no closer than the chosen value. Shown only if the automatic changeover is selected.| 0 ° C to 5 ° C (0 ° F to 10 ° F)| 3°C
9| Filter cleaning reminder| 0-5 months| 3
A| Standby screen brightness| 1-99| 4
B| Temperature Indication Scale| 0: °C display; 1: °F display| 1
C| Deadzone temperature for turning on/offload| 1 ° C to 5 ° C (2 ° F to 10 ° F)| 1°C
D| Fan Control in Heating| 0: Without control; 1: With control| 1
E| Change the system of heat pump and air conditioning| 0: Heat pump
1: Air conditioning| 0

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hangzhou Roombanker Technology User Manuals

Related Manuals