Kenmore 721.80032 Microwave Hood Combination Instruction Manual
- June 17, 2024
- Kenmore
Table of Contents
- Kenmore 721.80032 Microwave Hood Combination
- Product Information
- Specifications
- YOUR SAFETY FIRST
- PARTS, TOOLS, MATERIALS
- PREPARE THE ELECTRICAL CONNECTIONS AND VENTING SYSTEM
- PREPARE THE VENTING BLOWER
- PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION
- INSTALL THE MOUNTING PLATE TO THE WALL
- ATTACH THE OVEN TO THE WALL
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Kenmore 721.80032 Microwave Hood Combination
Product Information
Specifications
- Model Numbers: 721.80032, 721.80033, 721.80034, 721.80039, 721.80042, 721.80043, 721.80044, 721.80049
- Height: 16-7/16 inches
- Width: 29-15/16 inches
- Depth: 15-11/16 inches
- Weight: 51.8 pounds
Frequently Asked Questions
- Q: What should I do before drilling into the wall for installation?
- A: Before drilling, identify the location of electrical outlets and concealed electrical wires to avoid contacting them with your drill bit.
- Q: How should I ground the microwave oven?
- A: Ensure that the outlet used for the microwave oven is properly polarized and grounded. Connect the appliance to a three-pronged (grounding) outlet using the provided grounding plug. If you are unsure about proper grounding, consult a qualified electrician.
- Q: What are the included parts with the oven?
- A: The supplied parts include a damper/duct connector, one power cord clamp with a dark-colored mounting screw, one power cord clamp bushing, four 1/4 x 2 lag screws, two 1/4 x 3 bolts, four 1/4 x 3 toggle bolts, and two tapping screws.
Read and save these installation instructions.
YOUR SAFETY FIRST
BEFORE YOU START
- Proper installation is the installer’s responsibility!
- Read the entire manual before you begin.
- The model number label is located on the oven front. See Figure 1.
- Mounting plate is located on back side of microwave oven. See Figure 2.
BE SURE TO READ THE FOLLOWING SAFETY INSTRUCTIONS
WARNING
FOR YOUR SAFETY:
- You will need TWO people to install this oven. It is heaw and could cause personal injury if not handled properly. The dimensions of the oven are as follows:
- Height: 16-7/16 inches
- Width: 29-15/16 inches
- Depth: 15-11/16 inches
- Weight: 51.8 pounds
- AVOID ELECTRICAL SHOCK!
- Before you drill into the wall, note where electrical outlets are and where electrical wires might be concealed behind the wall.
- YOU COULD GET AN ELECTRIC SHOCK it you contact electrical wires with your drill bit.
- Locate and disconnect the power of any electrical circuits that could be affected by installing this oven.
- IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.
- ELECTRICAL RATING OF THIS OVEN : 120V, 60Hz.
- 14 Amps / 1500 Watts(Microwave oven + Cooktop Lamp + Ventilation Fan)
- You need a 120V, 60Hz, AC only, 15A or 20A, fused electrical supply (located in the cabinet above the microwave as close as possible to the microwave circuit) serving only the microwave.
- THIS APPLIANCE MUST BE GROUNDED!
- If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
- Place the plug into a properly installed and grounded outlet. See Figure 3.
- Do not use an extension cord.
- Keep the power cord dry and do net pinch or crush it.
- DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG!
- This appliance MUST be grounded!
WARNING: If you use the grounding plug improperly, you risk electric shock!
- Check with a qualified electrician if you are not sure whether the oven is properly grounded or if you do not completely understand the grounding instructions.
- DO NOT USE A FUSE IN THE NEUTRAL OR GROUNDING CIRCUIT.
WARNING
Improper grounding could result in electric shock or other personal injury.
SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR’S USE.
- DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY!
- DO NOT try to operate the microwave oven with the door open.
- DO NOT tamper with or defeat the safety interlocks.
- DO NOT place objects between the microwave oven front face and the door.
- DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door.
- DO NOT operate the microwave oven if it is damaged.
- The microwave oven door must close properly to operate safely.
- DO NOT use the microwave oven:
- If the door is bent.
- If the hinges or latches are broken or loose.
- If the door seals, sealing surfaces or glass is broken.
- DO NOT attempt to adjust or repair the oven yourself!
- It should be adjusted and repaired by a qualified technician who can check for microwave leakage after repairing the oven.
WARNING: If you do not use the microwave oven as instructed, you could be exposed to excessive microwave energy.
- MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT.
- Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2″ x 4″ wood studding and 3/8″ thick drywall or plaster/lath.
- ATTACH AT LEAST ONE of the two lag screws supporting the oven to a vertical, 2″ x 4″ wall stud.
- DO NOT mount the microwave oven to an island or peninsula cabinet.
- BE SURE the upper cabinet and rear wall structures are able to support 150 Ibs., plus the weight of any items you place inside the oven or upper cabinet.
- Locate the oven away from strong draft areas, such as windows, doors, and strong heating vents.
- BE SURE you have enough space. See Figure 4 below for minimum vertical and horizontal clearance.
WARNING: If you do not mount the oven as instructed, you risk personal injury and/or property damage.
CAUTION
- Before you begin installing the oven, PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL (a blanket) over the countertop or cooktop to protect it. Do not use a plastic cover.
- Failure to protect these surfaces could result in property damage.
PARTS, TOOLS, MATERIALS
THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:
NOTE: Depending on your ventilation requirements, you may not use all of these parts.
NOTE: You need to install at least one lag screw into a 2″ x 4″ stud and four anchor bolts into the wall, and the mounting area must meet the 150 Ibs. weight requirement.
YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE INSTALLATION:
Carton or other heavy material for covering the counter top.
- If you have brick or masonry walls, you need special hardware and tools.
- The ductwork you need for the installation is not included. All wall and roof caps must have a back-draft damper.
PREPARE THE ELECTRICAL CONNECTIONS AND VENTING SYSTEM
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS
WARNING: AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED!
- Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail.
- NOTE: The outlet should be on a circuit dedicated to the microwave oven 120V, 60Hz., AC only, with a 20ampere fused electrical supply.
- IMPORTANT: If you do not have the proper wall outlet, you MUST have one installed by a qualified electrician.
- You will cut the power-supply-cord hole (shown in Figure 4 Detail) later when you prepare the wall and upper cabinet in Step 4.
- NOTE: Do not use an extension cord.
- Keep the power cord dry and do not pinch or crush it.
WARNING: Improper grounding could result in electric shock or other personal injury.
- DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG!
- This appliance MUST be grounded!
STEP 2: PREPARE THE VENTING SYSTEM
NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9.
WARNING: FIRE HAZARD
THIS OVEN MUST BE PROPERLY VENTED!
You may vent your oven in one of three ways:
- Roof Venting: If your oven is located on an outside wall near the roof, as in Figure 6 (3-1/4″ x 10″ duct) and Figure 8 (6″ round duct.)
- Wall Venting: If your oven is located on an outside wall on the first floor of your house, as in Figure 5 (3-1/4″ x 10″ duct) and Figure 8 (6″ round duct.)
- Room Venting: If your oven is located on an inside wall of your house, as in Figure 7.
NOTE: If you choose the rear exhaust method (roof or wall venting), be sure there is enough clearance within the wall for the exhaust duct.
REMEMBER AS YOU INSTALL THE VENTING:
- Keep the length of the ductwork and the number of elbows to a minimum to ventilate your oven efficiently.
- Keep the size of the ductwork the same.
- Do not install two elbows together.
- Use duct tape to seal all joints in the duct system.
- Use caulking to seal the exterior wall or roof opening around the cap.
STANDARD FITTINGS
NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3″ extension duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking.
DUCT LENGTH
- The total length of the duct system, including straight duct, elbows, transitions, wall or roof caps must not exceed the equivalent of 140 feet.
- For best performance, do not use more than three 90 degree elbows.
- Below are the standard fittings and their equivalent length in feet.
To calculate the equivalent length of each duct piece used, see the examples below
PREPARE THE VENTING BLOWER
STEP 3: PREPARE THE VENTING BLOWER
Your microwave oven is shipped with the blower assembled for room venting (recirculating). You need to adjust the blower if you want wall vented or roof vented installation.
WARNING: ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT.
- DO NOT PULL OR STRETCH THE BLOWER WIRING! Pulling and stretching the blower wiring could result in electrical shock.
- Remove any shipping materials and parts from inside the microwave oven.
- Cover the counter top or cooktop with a thick, protective covering to protect it from damage and dirt. See Figure 10.
- NOTE: If you have a free-standing range, disconnect it, move it onto a piece of cardboard or hardboard and pull it away from the wall, so that you can get closer to the upper cabinet and back wall for easier measuring and drilling.
- Remove mounting plate 2 screws from the mounting plate as shown and discard them. (See Figure 11.)
- The mounting plate will also be used to locate and mark the mounting holes on the rear wall.
- Locate exhaust adaptor, grease filters and hardware packet.
- At this point, remove any adhesive tape (if there is any), on the exhaust adaptor, the grease filters and the power supply cord.
ROOM VENTED INSTALLATION:
- Go to STEP 4, PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION located.
WALL VENTED INSTALLATION:
- Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate from cabinet. See Figure 12.
- Carefully lift the blower unit out of the microwave oven. Disconnect the blower wire from connector. See Figure 13.
- Use side cutters or tin snips to cut and remove knockouts “B” from Back plate. Discard knockouts. Be careful not to distort the plate. See Figure 14.
- Rotate the unit so that the exhaust ports face the rear of the cabinet. See Figure 15. Before you insert blower unit, blower wire must be like Figure 15.
- Reassemble the blower wire into the connector.
- Place blower unit back into cabinet. Check that the exhaust ports face towards the rear of the cabinet. See Figure 16.
- Reattach the blower plate to the top of the cabinet as it was originally assembled. Attach with one blower unit mounting screw and then two blower plate mounting screws. See Figure 17.
- Go to STEP 4, PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION located.
ROOF VENTED INSTALLATION
- Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate from cabinet. See Figure 18.
- Carefully lift the blower unit out of the microwave oven.
- Rotate blower unit 90° so the exhaust ports face the top of the cabinet. See Figure 19.
- Place blower unit back into microwave oven.
- Use side cutters or tin snips to cut and remove knockouts “A” from blower plate. Discard knockouts. Be careful not to distort the plate. See Figure 20.
- Reattach blower plate to microwave oven. Attach with the one blower unit mounting screw and then the two blower plate mounting screws. See Figure 21.
PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION
MEASURE AND TACK / TAPE UP THE TEMPLATE
- Using a plumb line and (metal) measuring tape, find and mark the vertical center line (V)on the back wall, as in Figure 22.
- Find and mark one or two points where the studs are on the wall (Studs are normally 16 inches apart.) and then measure and mark the stud locations. If you cannot find any wall stud, consult a local building contractor.
- CAUTION: DO NOT ATTEMPT TO INSTALL THE MICROWAVE OVEN IF YOU CANNOT FIND A WALL STUD.
- Line up the plumb line on the wall with the center line on the mounting plate.
- NOTE: Be sure the minimum width is 30 inches and the distance from the top of the mounting plate to the range or countertop is at least 30 inches. See Figure 4.
- Center mounting plate in opening by lining up the plumb line on wall with centerline on mounting plate. Make sure the minimum width is 30 inches and that the top of the mounting plate is located a minimum of 30 inches above the cooking surface. See Figure 23.
- NOTE: If the front edge of the cabinet is lower than the back edge, adjust the mounting plate to be level with the cabinet front.
- Measure the bottom of the upper cabinet frame. Trim the edges “A”, “B” and “C” on the upper cabinet template so that the template will fit on the bottom of the upper cabinet. If upper cabinet has a recessed frame, trim template so that it fits inside the recessed area. Align the centerline of the upper cabinet template with the centerline of the mounting plate; then securely tape or tack the upper cabinet template in place. See Figure 23.
DRILL THE HOLES IN THE WALL AND UPPER CABINET
WARNING: BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL.
Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock.
- Find the points on the mounting plate labeled “A”, “B”, “C” and “D”. Drill a 3/16″ diameter hole at any of these points that are in front of a wall stud. Drill a 3/4″ diameter hole at any of these points that are over drywall.
- Drill a 3/8″ hole at points “J” and “K” on the upper cabinet template.
- NOTE: If the bottom of the upper cabinet is recessed 3/4″ or more, you will need 2″x2″ filler blocks (not included) to provide additional support for the bolts. See Figure 24.
- Mark the center of each filler block and drill a 3/8″ diameter hole at the mark.
- Align filler blocks over the two openings in the top of the microwave oven cabinet and attach to cabinet with masking tape. See Figure 25.
- Cut or drill a 2″ diameter hole at the area marked “M”, “power supply cord hole” on the upper cabinet template. If the upper cabinet is metal, you will need to cover the edge of the hole with the power supply cord bushing (supplied) to prevent damage to the cord from the rough metal edge.
- WARNING: YOU MUST COVER THE EDGE OF THE POWER SUPPLY CORD HOLE IN A METAL CABINET WITH THE POWER SUPPLY CORD BUSHING. FAILURE TO DO SO COULD RESULT IN DAMAGE TO THE CORD AND ELECTRIC SHOCK.
- Cut out the venting areas (with the saber saw):
- Roof Venting: cut out the shaded area marked “L” on the upper cabinet template.
- Wall or Room Venting (Recirculating): go to STEP 5, INSTALL THE MOUNTING PLATE, located.
- Use caulking compound to seal the exterior wall or roof opening around the wall cap or roof cap.
INSTALL THE MOUNTING PLATE TO THE WALL
STEP 5: INSTALL THE MOUNTING PLATE TO THE WALL
THE OVEN MUST BE CONNECTED TO AT LEAST ONE WALL STUD
- Draw a vertical line on the wall at the center of the 30″ wide space. Use the mounting plate as the template for the rear wall. Place the mounting plate on the wall, making sure that the tabs are against the bottom of the cabinet. Line up the notch and center line on the mounting plate to the center line on the wall.
- While holding the mounting plate with one hand, draw circles on the wall at holes “A”, “B”, “C” and “D”. Four holes must be used for mounting. If the holes are not used, the installation will not be secure. Installer must use these holes for proper installation. Use toggle bolts through these holes unless one of them lines up with a stud. Use a wood screw for studs. See Figure 26.
- NOTE: Draw a fifth circle inside area “E”, through one of the holes to match the location of a stud.
- For wall vented: The oven requires a rear wallcutout opening for the rear wall duct and the exhaust adaptor must be attached to the mounting plate. See the next page on how to prepare the rear wall cutout opening and the exhaust adaptor/mounting plate for wall vented.
- Drill holes through the circles. If there is a stud, drill a 3/16″ hole for lag screws. Two or preferably four lag screws at holes “A” and “C”, or “B” and “C” must be used to secure mounting plate to wall. If there is no stud, drill a 3/4″ hole for toggle bolts. Make sure to use at least 1 lag screw at holes of area “E” in a stud, and 4 toggle bolts at holes “A”, “B”, “C” and “D” in the drywall or the plaster.
- Attach the plate to the wall. To use spring toggle head bolts: Remove the toggle wings from the bolts. Insert the bolts into the mounting plate and replace the spring toggle heads to 3/4″ past the bolt ends. Insert the spring toggle heads into the holes in the wall to mount the bracket. You may pull forward on the bracket to help in tightening the toggle bolts. Tighten all bolts. See Figure 27.
TO PREPARE THE REAR WALL CUTOUT OPENING AND EXHAUST ADAPTOR/MOUNTING PLATE FOR WALL VENTING AND ROOF VENTING:
NOTE: If room vented installation is used, skip this step.
- Using the Wall-template.This template will give the location and size of the box cutout for the rear wall duct as described in step 5 item 1
- Using a pencil, put dots through slots “F” and “G”, and through holes “H” and ‘T’. Remove the mounting plate and draw lines extending through the points. This will give the location and size of the box cutout for the rear wall duct. See Figure 28.
- Attach the exhaust adaptor to the rear mounting plate by sliding it into the guides at the top center of the plate on the wall side. Push in securely until it is past the top locking tabs and in the lower locking tabs. Take care to assure the damper hinge is installed so that it is at the top and that the damper swings freely.
- Carefully guide the exhaust adaptor, now attached to the mounting plate, into the house duct, before using the screws to attach the plate to the wall. This will assure proper alignment for installation. See Figure 29.
- Return to step 5, item 3 to continue. After completing the installation of the mounting plate, again check the rear damper for free movement to assure it will operate properly.
ATTACH THE OVEN TO THE WALL
STEP 6: ATTACH THE OVEN TO THE WALL
WARNING: You will need two people to lift this microwave. Failure to use more than one person could result in personal injury.
- Carefully lift microwave oven and hang it on support tabs (See Figure 26) at the bottom of the mounting plate. Reaching through upper cabinet, thread power supply cord through the power supply cord hole in the bottom of the upper cabinet. See Figure 30.
- Rotate the microwave oven upward so the top of oven is against the bottom of the upper cabinet or cabinet frame.
- Then insert a bolt down through each hole in the upper cabinet bottom. See Figure 31. Tighten the bolts until the gap between the upper cabinet and microwave oven is closed.
- If wall vented or room vented installation is used.
- Roof vented installation: See Figure 32. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See “PREPARE THE VENTING SYSTEM,” STEP 2. Use caulking to seal exterior roof opening around the exhaust cap. See Figure 6.
- Use power supply cord clamp to bundle the power supply cord. Install the power supply cord clamp, using a screw as shown in Figure 33, to inside of the cabinet.
- To install the grease filter: Slide it into the slide slot, then push up and toward oven center to lock. See Figure 34.
- Plug in the power supply cord.
- Read your Owner’s Manual, then check the operation of your microwave oven.
Part No: MFL39433001
Sears, Roebuck and Co., Hoffman Estates, IL 60179
www.sears.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>