Parameter:
Input | DC12V+10% |
---|---|
Swipe distance | 0~4CM |
Working current | 200MA |
Card reading type | IC card |
Working mode | TCP/IP networking/offline |
issuing mode | management platform card issuing |
Working temperature | -20°C~70C |
Relative humidity | 20% ~ 93% |
Open mode | swipe card, APP, remote, password (optional) |
size | control box:273 232 67mm reading head :86 86 8MM |
Installation method | Control box: hanging installation reading head : 86 box |
embedded installation.86 box requires a depth of 50MM inside
Controller interface description Interface description:
Location | Function Description |
---|---|
J4 | Power and relay output interface |
J5 | Exit button and door magnetic detection interface |
J6 | 485 bus communication interface |
J1 | LAN cable crystal head interface |
ISW1(0 means no dialing, 1 means dialing toON) | Mode selection( 00: TCP/IP LAN |
networking,01:Offline)
Interface Name| Function Description
---|---
+12v| Power and relay output interface
GND| Exit button and door magnetic detection interface
NC| 485 bus communication interface
COM| LAN cable crystal head interface
NO| Relays normally open
EXIT| Exit key signal detection
DSW| Door magnet signal detection
485A/B| 485 bus A/B interface
System wiring referencess Wiegand Reader Installation diagram:
Connect the signal line in the back of the read head device as shown in the
figure below. (b) Install the reading head device into the 86 box, (note that
you need to use the embedded wall inside the depth of 50MM style 86 box), lock
the screws to fix, as shown in the figure below. (c) Read the head panel and
read the head body snap together, first from the upper snap down and then
press the lower and bottom screw hole alignment; finally in the bottom of the
anti-theft screw hole screwed on the countersunk head machine wire within the
plum security screws fixed,as shown in the figure below.
Multi-door Controll Function Description
Operating mode selection
Switch Setting | Indicates | Switch Setting | Indicates |
---|---|---|---|
Offline working | TCP ,IP LAN networking |
Startup status
TCP/IP LAN networking : When the power is on, the blue LED flashes, indicating
that it is looking for the network. When normally connected to 5the network,
the buzzer ‘tick ~ tick’ two short beeps, the LED red light is2 always on,
indicating that the cloud access control has started normally; when 20 seconds
later is not normally connected to the network, the5 5buzzer tick tick tick”
three beeps, the LED red light is always on, indicating Connection network
failure, the controller forced to start. After the controller is normally
connected to the network, the LED green light will flash once every 20
seconds, indicating that there is data and the cloud platform interactive
communication. Offline working: When the power is started, the buzzer “beep” a
short beep, the LED red light is always on, indicating that the cloud access
control has started normally.
Unlock status
When the lock is opened legally, the buzzer of the controller and the reading
head will be “beep” at the same time, accompanied by a green LED flashing
once, and the corresponding relay will be jumped, which means that the lock is
opened successfully; when the lock is opened illegally, the buzzer of the
controller and the reading head will be “beep beep beep” three times at the
same time, accompanied by a red LED flashing three times, which means that the
lock is opened and failed.
Unlock method
The device can be unlocked by swipe card, remote APP, out door button,
management center platform remote, cloud server platform remote, password
(optional), and many other ways.
Multi-door Controll Configuration
Management Center Add Controller
Connect the controller to the PC with a network cable, open the controller
management software, and click Add Controller by Search. At this time, the
management software can automatically search for the multi-door controllers
connected to the LAN and assign them to the corresponding IP. Then configure
the controller to the corresponding area. Click to confirm that the controller
can be bound to the corresponding regional access control. Add user and configure his permissions
In the management center, add users to configure the rights of the
corresponding area controllers for them. After the configuration is completed,
users can open the door in the room where these controllers are installed by
swipe card, APP, password, etc. More detailed controller management and
Add User: Configuration Permissions: Remotely open doors and view access records
After you open Trudian APP and log in the user you have added in the
management center, the APP home page shows all the controllers that the
current user can control. You can open the door remotely in APP, and you can
also view all the door opening information recorded by the controller in APP.
Website: www.trudian.com/en/
Address: Farbell Technology Park,Yixian Road, Nanlang,
Cuiheng New District, Zhongshan City, Guangdong Province,
China.Zip Code:528451
E-mail:
sales@trudian.nethttps://www.facebook.com/profile.php?id=100095678464232
https://www.linkedin.com/company/guangdong-trudian-technology-co-
ltd/about/?viewAsMember=true
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>